![auer Edel AIR 200 L Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/auer/edel-air-200-l/edel-air-200-l_installation-and-operating-instructions-manual_3015817005.webp)
Partial piping
Outdoor air
)FBUFE
premises
piping at the back
piping on the right
piping on the left
t*GJOTUBMMFEXJUIPVUQJQJOHUIFBQQMJBODFNVTUCFJOTUBMMFEJO
non-heated premises (of at least 20m2 ) away from neighbouring
heated rooms.
t*GUIFTQBDFBWBJMBCMFVOEFSUIFDFJMJOHJTMFTTUIBODNJOIFJHIU
above the water heater, we would recommend that you install an
elbow at the air outlet and direct it towards the back or the sides.
t5IFIFBUQVNQXBUFSIFBUFSFOBCMFTIFBUUPCFSFDPWFSFEGSPN
the floor of non-heated, partially underground premises such as
a workshop or garage.
t5IFIFBUQVNQXBUFSIFBUFSFOBCMFTEFIVNJEJGZJOHBOEDPPMJOH
of rooms such as utility rooms or cellars.
The heat pump can operate over a large air temperature range (from
-7°C to 35°C). The appliance extracts calories from outdoor air.
Partial piping (using only 1 pipe) onto outdoor air should be avoided,
as in the winter it can cause premises to become too cold.
2.3 - Air connection
If connecting to piping, you will need to
change the fan speed ( see § “Changing
the fan speed”)
2.3.1 - Without piping
2.3.2 - With piping
2.4 - Pipe dimensions
The
heat pump water heater
must be connected using
insulated
air ducts which are 160mm inside diameter.
Ø160 PVC elbows enable you to rotate the position of the pipes
connected to the appliance through 360°.
Total maximum length Ø160 :
tNøFYJCMFIPTF
tNSJHJEQJQJOH
1elbow = 1m
Fan accessories are available to order and are designed for simple
and efficient heat pump water heater connection.
The pipes (Ref. 730011) and the cellular foam elbows (Ref.
730012) are semi-rigid, light and thermally insulated.
They are assembled using a connector (Ref. 730014).
*GPWFSNMPOHUIFQJQFTNVTUCFöYFEUPUIFXBMMVTJOHBDPMMBS
(Ref. 730013).
The stainless steel horizontal terminal (Ref. 730015) is equipped
with a protective grille.
2.4.1 - Ventilation accessories
Figure
Part
Ref
. n°.
Semi-rigid pipe, 160mm Ø - lg 2m
730011
90° insulated elbow160mm Ø
730012
Collars for attaching to wall (set of 2)
730013
Connectors for insulated pipe (set of 2)
730014
Horizontal terminal for insulated pipe
730015
1
1
1
2
3
4
5
2
2
2
4
4
3
3
5
5
2
-
INSTALLER
- AIR SOURCE HEAT PUMP WATER HEATER -
INSTRUCTIONS
-
5