The R290 refrigerant in the heat pump
circuit poses no risk to the environment
but is inflammable.
ń
do not damage the pipes in the
refrigerant circuit
ń
do not handle a flame or any other
flammable source on the inside of the
appliance,
ń
if the refrigerant leaks, unplug the
appliance, air the room and contact the
after sales team,
ń
do not use any mechanical means to
speed up de-icing
ń
do not pierce or burn the appliance: in
case of intervention on the refrigerant
circuit, the refrigerant must be recovered.
When draining the tank, ensure that there is a large enough air
inlet at the top to avoid any depression in the tank. The following
material and products should be avoided:
- brushes with steel bristles
- scouring powder
- any bleach -based product or chlorinated derivative
In case of maintenance or if taking the heat pump water
heater out of service, please respect environmental protection
regulations regarding recovery, recycling and disposal of
consumables and components.
4 - MAINTENANCE AND
REPAIRS
In order to maintain efficiency and improve durability
we advise that an annual maintenance check be
carried out by a qualified professional.
t"OZXPSLPOUIFIFBUQVNQNVTUCF
carried out by a qualified professional.
t0CTFSWFIFBMUIBOETBGFUZSVMFT
t"OZXPSLPOUIFSFGSJHFSBOUDJSDVJUNVTUCF
carried out by a qualified professional with a
Category 1 certificate of aptitude.
t *UJTTUSJDUMZQSPIJCJUFEUPSFMFBTFSFGSJHFSBOU
into the atmosphere.
t5IFSFGSJHFSBOUNVTUCFDPMMFDUFECFGPSFBOZ
work is carried out on the circuit.
t4XJUDIPòUIFIFBUQVNQXBUFSIFBUFSCFGPSF
opening it.
t8BJUGPSUIFGBOUPDPNFUPBDPNQMFUFTUPQ
before starting work on the appliance.
t%POPUQVUXBUFSPOBOZFMFDUSJDBMQBSUT
t$IFDLUIFXFBSPOUIFNBHOFTJVNBOPEFFWFSZ
year.
4.1 - Water circuit / condensate draining
To check that condensates are draining correctly:
- Remove upper cover (see § “Electrical connections”).
- Check for blockages in the draining hole.
- Clean the condensate recovery container, where deposits
from air intake may have gathered.
- Clean the flexible draining hose.
The pressure limiting device must be switched on regularly to
eliminate limescale and check for blockages.
Check that all hydraulic connections onthe
heat pump water
heater
are watertight.
The only maintenance work needed is to clean the evaporator
(at least once a year and depending on the cleanliness of the air
UBLFOJO*GVTJOHBJSöMUFSTDIFDLJGUIFZBSFDMFBOSFHVMBSMZ
If necessary, clean or replace them.
4.2 - Air intake circuit
The fan blades are sharp-edged and can cause injury; take care
not to damage or deform them.
-
INSTALLER
- AIR SOURCE HEAT PUMP WATER HEATER -
INSTRUCTIONS
-
15