The equipment described in this operating instructions manual is a explosion proof device for use

in hazardous areas. As a device of equipment group II category 2G it is designed for use in gas areas

zone 1 and 2.

1. The  device  is  designed  in  compliance  with  insulation  class  I  and  may  be  connected  and

operated at the mandatory voltage only. A pr oper connection must be especially observed.

2. Waiting time until opening 15 sec.

3. Take  care  not  to  damage  the  housing.  During  maintenance,  check  accessible  seals  for

function. Damaged seals must be replaced.

4. The device may be operated under the mandatory ambient conditions only (refer to Technical

specifications). Bad ambient conditions may lead to damage to the device. Such bad ambient

conditions are:

too high continuous air humidity

inflammable gases, vapours, solvents, dusts

too low or too high ambient temperatures

5. The mandatory operational position of the device must be considered.

6. The device is meant for use indoors or outdoors.

7. During  operation  of  the  device  the  legal  and  professional  regulations,  the  safety  regulations,

and  the  electrical  rules  and  regulations  regarding  connection  and  operation  with  line  voltage

must be observed. Connection and commissioning may be done by an educated professional

only.

8. The  device  may  be  opened  by  educated  professional  personnel  only.  During  the  process  of

opening covers or removing parts live parts may be exposed.

9. If repairs or a replacement of parts include opening the device, the device must be separated

from all power sources prior to such work.

10. In  case  of  repairs  only  original  spare  parts  may  be  used.  Any  other  spare  parts  may  lead  to

personal injury and/or equipment damage.

11. If it is unavoidable to repair the powered device, this may be done by an educated professional

only. 

12. Continuous subjection to signalling and/or too small distance to the signalling source may cause

hearing damage.

Warning and safety notes

Änderungen und Irrtum vorbehalten

Subject to alterations or errors

Perfektastr. 102

A-1 230 Wien

Telefon   (00431) 813 82 20 

Telefax   (00431) 815 99 51

http://www.auer-signal.com 

e-mail: [email protected] 

J. Auer Fabrik Elektrischer Maschinen Gesellschaft m. b. H

Содержание AS1

Страница 1: ...Klemmen Lb und W Note Prior to installing the device these operating instructions must be read carefully In case of any damage and liabilities the latest version of the General terms of delivery of products and services in the electric industry is authorita tive Notes on use The explosion proof secondaray sonder is conceived for use in in dustrial hazardous areas in industry buildings or outdoors ...

Страница 2: ...s 75 V AC 23 Hz bis 54 Hz überlagerte Speisespannung 0 V DC bis 63 V DC Eingangsimpedanz bei 25 Hz Z 8 k Ω bei 50 Hz Z 4 k Ω Stromstärke I K 3 A Potentialausgleich Anschluss innen am Gehäuse Schutzklasse I Akustischer Signalgeber Lautsprecher Akustisches Signal 3 Tonruf Tonfolge 800 Hz 1067 Hz 1333 Hz 2 Tonruf ca 931 Hz ca 1253 Hz Tonfolgefrequenz 4 unterschiedliche Einstellungen über Schiebeschal...

Страница 3: ...ation position any wall mount ceiling mount Protection category IP 66 Explosion category II 2G Ex e ib mb IIC T6 Certificate of conformity BVS 03 ATEX E 430 2 9 1 1 w a L C M E o t g n i d r o c c a s e y l e b a l E C Ambient operation temperature 20 C to 40 C Storage temperature 40 C to 75 C Transport temperature 40 C to 75 C Relative humidity up to max 90 Telephone connection Terminals D Lb and...

Страница 4: ...2009 Die hier angewandten Normen sind mit dem Normenstand aus der EG Baumusterprüfbescheinigung verglichen worden Es gibt keine Änderungen des anerkannten Standes der Technik in Bezug auf dieses Gerät The edition of applied standards here has been compared with the edition in the EC Type Examination Certificate There are no changes in the state of the art apply to this equipment Les normes appliqu...

Страница 5: ...rgeschriebene Betriebsgebrauchslage des Gerätes ist zu berücksichtigen 6 Das Gerät ist für den Betrieb in Räumen oder im Freien bestimmt 7 Bei Betrieb des Gerätes sind die gesetzlichen und gewerblichen Vorschriften Unfallverhütungsvor schriften sowie elektrische Bestimmungen und Vorschriften zum Anschluss und Betrieb an Netzspannung zu beachten Der Anschluss und die Inbetriebnahme darf nur durch e...

Страница 6: ... operation of the device the legal and professional regulations the safety regulations and the electrical rules and regulations regarding connection and operation with line voltage must be observed Connection and commissioning may be done by an educated professional only 8 The device may be opened by educated professional personnel only During the process of opening covers or removing parts live p...

Отзывы: