page 3 – 7
220 / March 2000
O U T P U T M O D U L E
J7 - not used
J6 - 8dB
J5 - 4dB
J4 - 2 dB
Note: These jumpers set the fader scale factor that will be applied to each
input module at the DSP stage. Default setting is 12dB (J6 and J5 - installed).
J24 - RS-485/RS-232 Select
Jumper J24 selects the hardware interface type (RS-485 or RS-232) for the
serial Com port.
OFF ON
J24 RS-485 RS-232
J1 - J3 - RS-485 Termination
Jumpers J1 - J3 are used for RS-485 termination. Termination must be
switched in pairs (i.e., TX and RX BOTH ON or BOTH OFF) for a given Com
X port.
OFF ON Serial Port
J1 Not terminated Terminated TX
J2, J3 Not terminated Terminated RX
Global