Audison LRx 2.150 Скачать руководство пользователя страница 4

4

DESCRIPTION

Audison LRx 2.150, LRx 2.250 and LRx 2.500:

Car stereo power amplifiers characterised by excellent musical performances, small size and outstanding
energy reserve.
Their power supply stage is made with 70A MOSFETs (one pair in LRx 2.150, two pairs in LRx 2.250 and
three pairs in LRx 2.500); it is PWM, stabilised and oversize.
Input stage is provided with a special circuit (LNS) which permits the system disturbances rejection,
reducing noise that is usually due to the vehicle electric parts (alternator, electronic injection, etc.),
without altering musical signal quality.
Driver stages are characterised by a very linear circuitry. They have coupled differential transistors and an
A Class complementary voltage amplifier. Power sections have Darlington configuration with high gain
and SOA (Safety Operation Area) BJT TO247. Thanks to their great capacity to supply current, these
amplifiers can easily drive even the most difficult loads and satisfy whatever power needs. They can give
powers between 80 and 200W per channel with 4 Ohm load and between 110 and 330W per channel at
2 Ohms in continuous mode. Powers range increases in mono mode (bridged) and it is between 220 and
660W on 4 Ohms. Differently from what occurs with other amplifiers, LRx 2 are not blocked by protection
systems immediately below 2 Ohms. Their exclusive “Overload Limiter” circuit allows them to go on
working, limiting output power and pointing out how hard the applied load is by the “Limit” LED
blinking.
Their big power reserve, their constant control at low frequencies and their exquisite timbre qualities
make them ideal components to realise systems designed to attain outstanding musical features and
very high sound pressures (SPL).
LRx 2 have two bypass HI-PASS and LO-PASS filters with non independent frequencies. Their
configuration is Butterworth, 12dB/Oct.
A switch permits to decide whether to send the HI-PASS section or the LO-PASS one to power stages.

In case LRx amplifiers are used in extremely difficult conditions (very low loads) or in installations where
space is too narrow and their heat sink cooling is not enough, they can be employed together with
CLK2 cooling system (optional). It is a system made of two units to apply onto the amplifier sides; each
of them is provided with an electronically controlled fan that allows the amplifier thermal stabilisation
(see “CLK2 – LRx Cooling Kit”).

LRx 2 protection includes:

RGP

(Resettable Ground Protection) circuit; in case a short circuit occurs between loudspeakers outputs

and car chassis, it detects a high current flow in the pre-input ground and acts by putting the amplifier 
in stand-by, protecting its circuitry;

• a device against short circuits and against DC in the outputs, to protect loudspeakers;
• a device that detects the amplifier temperature excessive increase and stops its functioning until optimal

conditions occur again.

Once the causes which implied protection circuits intervention have been checked and solved, the
amplifier is reset by switching it off and on again.
The amplifier is also provided with another general protection which is insured by an internal strip fuse,
very easy to reach.

Optional:

- CLK2 cooling system is available upon request.

21

INSTALLATION

LOGO ROTATION

1 - 

Remove the transparent

cover which protects
controls and then the 4
screws which block the
metal plate by using
multispanner.

2 - 

Remove the plate without damaging the

silkscreen printed panel which will have to
stay on. We suggest that you seize both
plate grips with your hands and pull them
by blocking the silkscreen printed panel
with your fingers against the amplifier
chassis at the same time. This will permit to
remove the plate from the panel without
damages.

3 - 

Remove the strip with

audison

logo.

5 - 

Mount the plate

back by fixing it
through the screws;
then, re-assemble the
transparent cover
which protects
controls

4 - 

Put the strip back again after turning it,

so that 

audison

logo is upside down.

Содержание LRx 2.150

Страница 1: ... measurement standards Power measures taken according to audison standard 1998 edition 12VDC and 13 8VDC 1 kHz or crossover cut off frequency 0 3 THD nominal power 1 THD continuous power Tolerance 10 5 Continous power given by RMS Voltage measured on resistive load The nominal power of the amplifier is measured upon a battery voltage of 12 Volts with a 4 Ohm load and with all channels in function ...

Страница 2: ...that the cable coming from the battery positive pole doesn t touch the amplifier heat sink The heat sink is directly connected to the battery negative pole through the screws which fix it to the vehicle chassis Its contact with the positive pole cable would cause short circuit and thus possible fires and battery damages Please connect power supply cables to the amplifier terminal blocks POWER and ...

Страница 3: ...2 Electric connections 22 audison cable products for electric connections 23 audison measurement standards 24 22 INSTALLATION AMPLIFIER FIXING ELECTRIC CONNECTIONS CAUTION For the system safer protection we recommend the use of a strip fuse on the cable that connects the battery positive pole to the amplifier POWER terminal block This fuse has to be installed about 10 cm far from the battery its v...

Страница 4: ...ide whether to send the HI PASS section or the LO PASS one to power stages In case LRx amplifiers are used in extremely difficult conditions very low loads or in installations where space is too narrow and their heat sink cooling is not enough they can be employed together with CLK2 cooling system optional It is a system made of two units to apply onto the amplifier sides each of them is provided ...

Страница 5: ...5 IN OUT PANEL FUNCTIONS 20 CONFIGURATION EXAMPLES MULTICHANNEL ...

Страница 6: ...6 POWER SUPPLY PANEL FUNCTIONS 19 CONFIGURATION EXAMPLES FRONT REAR SUB ...

Страница 7: ...age drops along the line and will make the device perfect functioning easier 2 Remove the screws which fasten the fuse to eliminate pieces of the broken one prevent them from going into the device FUSE REPLACEMENT 18 CONFIGURATION EXAMPLES FREQUENCY Hertz SPEAKERS IMPEDANCE 4 Ohms 8 Ohms L mH C µF L mH C µF 60 80 100 120 150 10 6 7 9 6 4 5 3 4 3 660 495 400 330 265 21 0 15 9 12 7 10 6 8 5 330 245 ...

Страница 8: ...ed to check if there are any failures or a too difficult load that s to say impedance is about 50 lower than the minimum recommended one The amplifier can go on functioning in these conditions but power will inevitably decrease 1 ON green LED It indicates the amplifier is on 2 1 2 3 4 9 8 10 7 5 6 AMP HI LO PASS Pre Out Lo Hi Pass It permits to choose which type of signal Lo Pass or Hi Pass to sen...

Страница 9: ...crossover point between 40 and 500 Hz 6 LEVELS It adjusts the input sensitivity of both amplifier channels and sets their output level 5 SAFETY red LED It indicates that the amplifier protection circuits are on In order for the amplifier to work again you need to switch the system off and then on after 10 seconds at least We recommend to check all connections before switching the amplifier on agai...

Страница 10: ...ss 12dB Oct Hi Pass Lo Pass 40 500 Hz 400 5000 Hz Pre Out Bypass 12dB Oct Hi Pass Lo Pass 40 500 Hz 400 5000 Hz Inputs IN L R OTHER FUNCTIONS Remote IN 7 15 VDC 1 mA Remote OUT 12 VDC 10 mA Auxiliary power supply PPS 12 VDC 300 mA Fuse 20 A MAX SIZE L x H x D 176X56X260 mm WEIGHT 2 6 kg 119 mm 272 mm 176 mm 300 mm SIZE FOR FIXING LRx 2 150 LRx 2 250 LRx 2 500 LRx 2 150 Drilling dimensions for fixi...

Страница 11: ...4 Ohms FILTERS INPUTS IN L R Bypass 12dB Oct Hi Pass Lo Pass 40 500 Hz 400 5000 Hz Pre Out Bypass 12dB Oct Hi Pass Lo Pass 40 500 Hz 400 5000 Hz Inputs IN L R OTHER FUNCTIONS Remote IN 7 15 VDC 1 mA Remote OUT 12 VDC 10 mA Auxiliary power supply PPS 12 VDC 300 mA Fuse 30 A MAX SIZE L x H x D 176X56X300 mm WEIGHT 3 0 kg LRx 2 250 POWER SUPPLY Voltage 11 15 VDC Idling current 1 1 A Idling current wh...

Страница 12: ...ts of two units to apply onto the amplifier sides each of them is provided with an electronically controlled fan Its intervention depends on a thermal sensor that starts the system as soon as LRx heat sink reaches 45 C The same sensor is connected to a special circuit which controls the two fans speed progressive increase when temperature increases too Air flux constant control allows the amplifie...