background image

128-6602

12 of 16

12

TESTING YOUR INSTALLATION:
CAUTION!! 
The following procedure must be performed after the installation of an Audiovox Remote Start

Device.  It is the responsibility of the installing technician to complete these tests.  Failure to
test the unit in the following manner may result in personal injury, property damage, or both.

HOOD PIN SAFETY SHUT DOWN:
The intention of the hood pin safety shut down is to prevent the Remote Start unit from being activated while
a mechanic or vehicle owner is performing normal routine vehicle maintenance.
To test the integrity of this circuit:

1. With the drivers window in the down position, start the vehicle using the RF transmitter.
2. Reach inside the car and pull the hood release.
3. Raise the hood and confirm that the remote start unit shuts down.

If the unit fails this test, recheck your pin switch connection to the Gray/Black wire of the Audiovox Remote
Start Unit.

DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE

OPERATION OF THE HOOD PIN SAFETY SHUT DOWN FEATURE.

MANUAL SHUT DOWN / ENABLE CIRCUIT:
The intent of the manual shut down / enable circuit is to allow the vehicle operator to prevent operation of the
Remote Start Unit regardless of the RF transmitter operation.
To test the integrity of the manual shut down / enable circuit:

1. Place the control switch in the on (Closed To Ground) position.
2. Start the vehicle using the RF transmitter.
3. The vehicle should start and run under the control of the remote start unit.
4. Move the switch to the off (Open From Ground) position, the vehicle should shut off.

If the unit fails this test, recheck your enable switch connection to the Ground and the Black/White wire of
the Audiovox Remote Start Unit.  If you have a plug in enable switch, check that the two pin connector is
firmly seated in the mating connector on the control module.

DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE

OPERATION OF THE MANUAL SHUT DOWN / ENABLE FEATURE.

NEUTRAL START SAFETY TEST:
The intent of the neutral start switch is to prevent the vehicle from starting while the gear selector is in any
position other than Park, or Neutral.  When installing a Remote Start Device, it is imperative that the Yellow
Starter wire be connected to the ignition switch side of the Neutral Start Switch.  Consideration for the
placement of a starter inhibit relay is important as well, and should be connected to the ignition switch side
of the Yellow Start Wire.
To test the integrity of the Neutral Start Safety Circuit:

1. Set the vehicle parking brake.
2. Block the drive wheels to prevent vehicle movement.
3. Temporarily disconnect the Brown/Black positive shut down wire from the vehicle's brake  switch.
4. Sitting in the vehicle, start the engine using the vehicle's ignition key.
5. Step on the brake pedal and shift the gear selector into reverse.
6. Allow the transmission to shift.  When you feel the engine pull, do not move the gear selector just  turn

the ignition switch off.  DO NOT attempt to remove the key.

7. Keeping the brake pedal depressed, activate the RF transmitter in an attempt to start the vehicle.  The

car should not start.

8. Repeat the above test, but this time move the gear selector to the drive position. If the unit attempts to

start, failing this test, recheck your Yellow Wire's connection. This wire must be connected to the

Содержание 1286602

Страница 1: ... Systems Gasoline or Diesel With True Tach Reference And Automatic Transmissions Only Kit Contents 1 Control Module 1 MultiPinInput OutputHarness 1 Six Pin Power Harness 1 Four Pin Auxiliary Harness 1 Three Pin I O Harness 2 30 Amp In line Fuse Holders With Fuses 1 Control Switch Programming Switch 1 Ring Terminal 4 1 2 Long Screws 1 Pin Switch 1 Remote Start Warning Label 1 Literature Package 1 ...

Страница 2: ...firewall behind the hood seal In either case the switch must be set up to allow the hood door to depress the switch at least 1 4 inch when the hood is closed and fully extended when the hood is opened For direct mounting a 1 4 inch hole must be drilled Carefully check behind the chosen location to insure the drill will not penetrate any existing factory wiring or fluid lines Drill a 1 4 hole in th...

Страница 3: ...e Tech Update issued 9 30 96 YELLOW Wire Starter Output Careful consideration for the connection of this wire must be made to prevent the vehicle from starting while in gear Understanding the difference between a mechanical and an electrical Neu tral Start Switch will allow you to properly identify the circuit and select the correct installation method In addition you will realize why the connecti...

Страница 4: ...nnect this wire to the Accessory wire from the ignition switch This wire will show 12 volts when the ignition switch is turned to the ACCESSORY or ON and RUN positions and will show 0 volts when the key is turned to the OFF and START or CRANK positions WIRING CONNECTIONS 12 Pin Input Output Harness Black Wire Chassis Ground Source Connect the Black wire to a known vehicle ground source or to a sol...

Страница 5: ...Remote Starter will stop operating even if the signal is received from the transmitter If the vehicle has a factory installed hood pin switch and that switch provides 12 Volts to an under hood light the Brown wire can be connected to the existing pin switch BROWN w BLACK Tracer Wire Positive Inhibit Input 2 Any time 12 Volts is applied to the Brown w Black tracer wire the Remote Starter will stop ...

Страница 6: ...d during the Remote Start activation period then vibration from the running vehicle can cause the alarm to trigger In this case connect the Light Blue Wire to terminal 86 of a external relay Connect terminal 85 of the relay to a fused 12 volt battery source Cut the shock sensor trigger wire and connect one end of the cut wire to terminal 30 and the other end of the cut wire to terminal 87a Just be...

Страница 7: ...ut will allow the ignition to keep the glow plugs active for the vehicles automatic time out period before cranking the starter motor If this wire is connected to the glow plug wire this will take precidence over the timing setting and the gas Diesel selection in the feature selection chart Use this wire if you do not want to set the timing of the glow plug preheat circuit as shown in the feature ...

Страница 8: ... This wire is also referred to as the ECM wake up wire in some Chrysler vehicles NOTE The outputs above are low current outputs and must be used with a relay if the circuit s requirement is more than 300 mA 4PINKEYLESSENTRYUPGRADEINPUTTRIGGERWIRES The system allows the factory keyless entry units to directly trigger the remote start providing the factory system sequentially unlocks first the drive...

Страница 9: ...ctable features 1 Start with the ignition switch in the OFF position and the programming switch in the ON position 2 Turn the ignition key to the ON position 3 Within 5 Seconds begin to toggle the control program switch OFF ON OFF ON OFF then ON 3a Parking Lights Turn On 4 Within 5 Seconds Turn the ignition key OFF then ON 4a Parking Lights Turn Off 5 Within 5 Seconds begin to toggle the control p...

Страница 10: ... Off Position 5 Flashes RF shutdown Remote signal received or manual start trigger wire reactivated 6 Flashes High RPM Signal Received 7 Flashes Tach Signal Has Not Properly Been Learned TIMEDSTARTPROGRAM The Remote Start unit has the ability to start the vehicle automatically at timed intervals This feature is useful in extremely cold climates where starting the engine is the only means to keep t...

Страница 11: ...g out the firing order of the engine in groups of as indicated below Draw a circle around any of the columns The Green Black wires should be connected to the negative terminal of the respective cylinder number which appears in any of the circles 2 For vehicles utilizing 2 cylinder firing per coil pack connect Green Black to the tach side of each coil pack For 8 cylinder four coil systems connect t...

Страница 12: ...ld shut off If the unit fails this test recheck your enable switch connection to the Ground and the Black White wire of the Audiovox Remote Start Unit If you have a plug in enable switch check that the two pin connector is firmly seated in the mating connector on the control module DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERATION OF THE MANUAL SHUT DOWN ENABLE FEATURE NE...

Страница 13: ...e vehicle Park Neutral ECM Input or the vehicle key in sensor This connection will prevent remote start operation if the key is left in the ignition switch regardless of the gear selectors position PARK NEUTRAL ECM INPUT The Park Neutral ECM input is the preferred method of installation This not only maintains the integrity of the factory circuit it is also the easiest to install providing the veh...

Страница 14: ... may also effect other warning tones such as the light on reminder These situations should be carefully considered before altering the vehicle s wiring and must be fully explained to the consumer The Following circuits may be used only if the above circuit is not available METHOD 1 To connect to the key in sensor as shown in method 1 A Locate the control wire that connects the drivers door pin swi...

Страница 15: ...his manual COMPLETING THE INSTALLATION After you have confirmed the operation of the Audiovox Remote Start unit and tested all the safety features of the system 1 If you have not done so already place the red rubber handle cover over the handle of the control switch for ease of identification This will allow your customer to distinguish the Remote Start control switch from the program switch 2 Mou...

Страница 16: ...128 6602 16 of 16 16 2003 Audiovox Electronics Corp Hauppauge N Y 11788 128 6602 ...

Отзывы: