EQUIPMENT FEATURES AND CONTROL ELEMENTS PRECISION P400

15  Selector switch for channels A and B

To switch the internal active crossover to highpass/full range (line-

ar) or lowpass/bandpass.

If this switch is set on Highpass the exactly frequency can be set

with control No. 21.

At switch position lowpass/bandpass the highpass is always

active. That means a Bandpass is built in any case. With control

21 adjust the highpass and with control 22 adjust the lowpass.

Thus every desired bandpass between 15 Hz and 4000 Hz can be

adjusted.

16  Selector switch for channels C and D

To switch the internal active crossover to highpass/full range (line-

ar) or lowpass.

If this switch is set on Highpass the exactly frequency can be set

with control No. 23.

At switch position lowpass/bandpass the highpass is always

active. That means a bandpass is built in any case. With control

23 adjust the highpass and with control 24 adjust the lowpass.

Thus every desired Bandpass between 15 Hz and 4000 Hz can be

adjusted.

Caution! To avoid a lost of sound pressure make sure that

the crossover frequencies of high- and lopass are separa-

ted of 2 octaves when building a bandpass.

That means: If the lowpass signal is adjusted to 320 Hz the hig-

hpass should be adjusted 2 octaves lower on approx. 80 Hz (1

octave=double frequency or half frequency).

If a subwoofer is connected we recommend to use high-

pass control 21 as variable subsonic filter or to turn con-

trol 21 counter-clockwise to 15 Hz to get a subsonic filter.

Connecting the remote lead
Connecting the battery cable 
Connecting the ground cable
Fuses 3 x 25 Ampere
Fuse function indication
Signal inputs
Level controls for input sensitivity
Signal input selector
Selector switch for channels A and B

Selector switch for channels C and D

Mono/Stereo selector
Speaker terminals for CH A and B
Speaker terminals for CH C and D
Frequency control highpass A and B
Frequency control lowpass A and B
Frequency control highpass C and D
Frequency control lowpass C and D
Colour protection system

1
2
3
4
5

6-9

10-13

14
15

16

17-18

19
20
21
22
23
24

25-27

9

8

7

6

14

3

2
1

10

11

12

13

5

4

25

26

27

15

16

21
22
23

24

17

18

A

19

B

C

20

D

A

B

A

B

A

B

1  Connecting the remote lead

The remote lead is connected to the automatic antenna (aerial

positive) output of the head unit (radio). This is only activated if

the head unit is switched ON. Thus the amplifier is switched on

and off with the head unit.

2  Connecting the battery cable

Connect the +12 V power cable to the positive terminal of the

battery. Recommended cross section: min. 16mm

2

3  Connecting the ground cable

The ground cable should be connected to a central ground refe-

rence point (this is located where the negative terminal of the bat-

tery is grounded at the metal body of the vehicle), or to a bright

bare-metal location on the vehicle chassis, i.e. an area which has

been cleaned of all paint residues.

4  Fuses

The input fuses are connected in parallel and provide protection

against an internal equipment fault, i.e. the system must be addi-

tionally protected by a further line fuse located in the vicinity of

the battery (max. distance from battery: 30 cm). The fuse rating

is 3 x 25 ampere for both amplifiers.

5  Fuse function indication

If the fuses (4) are destroyed due to malfunction the red LED illu-

minates. In normal operation the LED turns off. 

6 - 9  Signal inputs

The PRECISION amplifiers have RCA connectors for RCA cables

that can be connected with the pre-amplifier output of the line-

outputs of the headunit or with a pre-amplifier. This connectors

are gold-plated to ensure a better signal transmission.

10 - 13  Level controls for input sensitivity

These controls can be used to match the input sensitivity of the

individual channels to the output voltage of the connected head

unit. These controls are not volume controls and are solely inten-

ded for the purpose of sensitivity trimming. The control range

extends from 300 mV to 8,5 V.

14  Signal input selector

If only one stereo signal is available (i. e. 2 cinch leads connec-

ted), the inputs can be connected from A to C and from B to D by

setting the selector switch to position 2. When selector is set to

position 1, all the inputs are separate.

Содержание Helix Precision P400

Страница 1: ...4 Channel High End Amplifier G E R M A N Y B E D I E N U N G S A N L E I T U N G I N S T R U C T I O N M A N U A L deutsch english ...

Страница 2: ...tigen vergewissern Sie sich daß keine elektri schen Kabel und Komponenten hydraulische Bremsleitungen der Benzintank etc dahinter verborgen sind Diese könnten sonst beschädigt werden Achten Sie darauf daß solche Teile sich auch in der doppelten Wandverkleidung verbergen können Allgemeines zum Anschluss der Verstärker Der Verstärker darf nur in Kraftfahrzeuge eingebaut werden die den 12V Minuspol a...

Страница 3: ...chpass gestellt so kann mit Hilfe des Reglers 23 die exakte Frequenz eingestellt werden Bei der Schalterstellung Tiefpass Bandpass ist der Hochpass immer aktiv Das heißt es wird in jedem Fall ein Bandpass gebil det Mit dem Regler 23 wird der Hochpass und mit dem Regler 24 der Tiefpass eingestellt So kann jeder beliebige Bandpass zwi schen 15 Hz und 4000 Hz eingestellt werden Achtung Bitte vergewis...

Страница 4: ...isiko gehen zu Ihren Lasten d Die Kaufquittung muss beiliegen 5 Von der Garantie ausgenommen sind a Transportschäden sichtbar oder unsichtbar Reklama tionen für solche Schäden müssen umgehend bei der Transportfirma eingereicht werden b Kratzer in Metallteilen Frontabdeckungen usw Diese Defekte müssen innerhalb von 5 Tagen nach Kauf direkt bei Ihrem Händler reklamiert werden c Fehler die durch fehl...

Страница 5: ...he car audio system Install the cabling in a manner which precludes any danger of the leads being exposed to shear crushing or rupture forces If there are sharp edges in the vicinity e g holes in the bodywork all cables must be cushioned and protected to prevent fraying Never lay the power supply cables adjacent to leads and lines connecting other vehicle equipment fan motors fire detection module...

Страница 6: ...C and D Colour protection system 1 2 3 4 5 6 9 10 13 14 15 16 17 18 19 20 21 22 23 24 25 27 9 8 7 6 14 3 2 1 10 11 12 13 5 4 25 26 27 15 16 21 22 23 24 17 18 A 19 B C 20 D A B A B A B 1 Connecting the remote lead The remote lead is connected to the automatic antenna aerial positive output of the head unit radio This is only activated if the head unit is switched ON Thus the amplifier is switched o...

Страница 7: ...rol for lowpass of CH A and B Control for the adjustment of the crossover frequency from 15Hz to 4 kHz 23 Frequency level control for highpass of CH C and D Control for the adjustment of the crossover frequency from 15Hz to 4 kHz TECHNICAL DATA PRECISION P400 Cont power rating at 4 Ohms per channel 4 x 110 190 Watts RMS Music Cont power rating at 2 Ohms per channel 4 x 175 300 Watts RMS Music Cont...

Страница 8: ...8 Gewerbegebiet Lake II Hünegräben 26 D 57392 Schmallenberg Tel 49 0 29 72 97 88 0 Fax 49 0 29 72 97 88 88 E mail helix audiotec fischer com Internet www audiotec fischer com ...

Отзывы: