background image

2.  Please check if the fuse holder contains the correct fuse.
    6 A fuse (T) if the voltage selector is set on “115” or
    3 A fuse (T) if the voltage selector is set on “230”.
        

Note

        

A 3 A fuse (T) is set into the fuse holder when the PROLOOP DCCplus induction loop amplifier is  

        

delivered.

3.  Use a locally approved power cable to connect the loop amplifier to the mains socket. 

2.11 First-time operation

Before you switch on the device, please turn all the control knobs as far to the left as possible. 
- Connect a sound source to audio input 1.
- Connect the loop amplifier to the mains power supply.
- Set the AGC/Limiter switch on the Limiter position.
- Switch the audio source on.
- Switch the amplifier on. The indicator for the power supply (2) and the fault indicator (4) will light up during the  
  self-testing. After about 45 seconds the fault indicator light will go out and the amplifier is ready for use.
- Increase the volume of audio input 1 with its input volume control (6) until the Limiter LED lights up.
        

- Increase the electric current through the induction loop with the Power control (12) on the front of the amplifier.  

- Use the earphone jack (13) to listen directly and, if necessary, adjust the sound with the bass (7) or treble (8)  
  control. 

2.12 Adjusting the field strength

You  will  need  a  field  strength  gauge  (special  accessory)  to  calibrate  the  system  correctly  according  to  the  
IEC 60118-4 standard.

2.13 Metal loss compensation

You will get a loss of the magnetic field strenght if you have strong reinforcement metal in the floor. 
To compensat this loss use the metal loss compensation control on the rear side of the loop amplifier. 
Please follow the steps below to set the metal loss compensation:
1. Turn the Metal loss compensation control to the left position.
2. Connect headphones to the headphone socket of the amplifier and listen to the audio signal.
3. Use an inductive loop receiver and the same headphones to listen to the audio signals of the inductive loop.
4. Turn the Metal loss compensation control to adjust the tone of the audio signal.

English 21

230V AC

115V AC

IN 1

IN 2

MAIN

TREBLE

BASS

Содержание PRO LOOP DCCplus

Страница 1: ......

Страница 2: ...killfully combines appealing design with high technical performance This handbook describes exactly how the amplifier works and how it is to be used Please read through the operating instructions care...

Страница 3: ...t the rear panel 14 Fan outlet Please do not cover it so that any heat generated by the device can be dissipated 15 Fault output Gives the status of the loop amplifier to other equipment 16 Supervisio...

Страница 4: ...or music signals as high quality pleasant sound 1 6 Notes on safe operation This device complies with all the necessary EU directives and bears the CE seal of approval To make sure that your device en...

Страница 5: ...ake sure that the amplifier is mounted securely and will not slip or fall To prevent any damage to the internal components you should not screw screws or drill holes in the device enclosure Make sure...

Страница 6: ...al area of 0 5 mm and 1 5 mm You can use AWG 20 wire or a wire with a standard diameter of 1 00 mm cable cross sectional area 0 75 mm Note The inductive loop system works correct if the DC direct curr...

Страница 7: ...gnals with a strenght of more than 0 dBV are not sent to the connected indu tion loop 2 4 2 Switching the desired function on Use the AGC Limiter switch 24 to switch between AGC or Limiter function If...

Страница 8: ...y input to make sure that it is not possible to touch the priority input 2 8 Fault output You can send the condition of the loop amplifier to an external devices e g siren with the voltage free fault...

Страница 9: ...control 6 until the Limiter LED lights up Increase the electric current through the induction loop with the Power control 12 on the front of the amplifier Use the earphone jack 13 to listen directly a...

Страница 10: ...at s why we recommend that you use the services provided by HUMANTECHNIK We support architects technicians and installation ex perts qualified in the planning of LOS installations 3 3 Installation of...

Страница 11: ...has a greater resistance Connect the cable ends of the loop to the corresponding terminals 28 on the rear panel of the amplifier Make sure that you do not mix up the ends of the master and the slave c...

Страница 12: ...ing audiences 7 Check the average field strength by running diagonally over the induction loop area and determine the aver age of the values indicated The average value has to measure 0dB 3dB If you d...

Страница 13: ...nment and your health Material recycling also helps to reduce the use of raw materials Further information on recycling this pro duct is available from your community the municipal waste disposal depa...

Страница 14: ...info humantechnik com Tel 41 0 61 6 93 22 60 Fax 41 0 61 6 93 22 61 E mail info humantechnik com Tel 33 0 3 89 44 14 00 Fax 33 0 3 89 44 62 13 E mail sms audiofr com Hoorexpert BV Gildenstraat 30 NL...

Отзывы: