background image

22 English 

3 Setting up a LOS loop system with PROLOOP DCCplus

If you want to set up a LOS loop system you need two of the PROLOOP DCCplus. The first amplifier will be the 
master unit and the second amplifier will be the slave unit. 

3.1 Master and Slave configuration

- To define the first amplifier as Master amplifier the Master/Slave switch must be set on Master position. 
- The second amplifier must be defined as Slave amplifier by setting the Master/Slave switch on Slave position.

        

Note

        

The slave amplifier can only send the signal that it receives from the master amplifier to its induction  

        

loop. The audio inputs and the priority input of the slave amplifier are disabled.

3.2 LOS induction loops  

The optimal designs and configurations are always dependent on the venue details, i.e. the floor plans and the 
sizes of the rooms serviced, the number of internal induction loops and the demands made on low overspill.
To determine the corresponding values for the »tailored« low-overspill layout and the optimal level adjustments 
in each case, it is necessary to use complicated calculation and installation methods. That’s why we recommend 
that you use the services provided by HUMANTECHNIK. We support architects, technicians and installation ex-
perts qualified in the planning of LOS installations.

3.3 Installation of the induction loop

To use a LOS system, the induction loop must be installed in a special way. In detail, two separate loops are  
used (master/slave), which consist of eight-piece segments lined up one after the other. The exact proportions 
and the exact number of segments depend on the demands made on low overspill as well as the size of the  
room. The smaller the segment, the smaller the overspill will be.
The master loop is laid over the entire area to be serviced. The slave loop is always one segment shorter than the 
master loop and doesn’t begin until after the first segment half of the master loop. The individual segment lengths 
should correspond to the distances between the seating rows.
We recommend using a single-strand cable, e.g. H07V-K or the copper ribbon cable (A-4937-0). Please refer 
to  section “2.1 Cable cross section and wire diameter” for the needed cable cross section of the single-strand 
cable. 

3.4 Advantages of a LOS induction loop design

- No loss of field strength in the centre of the induction loop
- No horizontal overspill
- No signal holes inside the loop

MASTER

SLAVE

VU LED

PRE Amp. POST Amp.

Содержание PRO LOOP DCCplus

Страница 1: ......

Страница 2: ...killfully combines appealing design with high technical performance This handbook describes exactly how the amplifier works and how it is to be used Please read through the operating instructions care...

Страница 3: ...t the rear panel 14 Fan outlet Please do not cover it so that any heat generated by the device can be dissipated 15 Fault output Gives the status of the loop amplifier to other equipment 16 Supervisio...

Страница 4: ...or music signals as high quality pleasant sound 1 6 Notes on safe operation This device complies with all the necessary EU directives and bears the CE seal of approval To make sure that your device en...

Страница 5: ...ake sure that the amplifier is mounted securely and will not slip or fall To prevent any damage to the internal components you should not screw screws or drill holes in the device enclosure Make sure...

Страница 6: ...al area of 0 5 mm and 1 5 mm You can use AWG 20 wire or a wire with a standard diameter of 1 00 mm cable cross sectional area 0 75 mm Note The inductive loop system works correct if the DC direct curr...

Страница 7: ...gnals with a strenght of more than 0 dBV are not sent to the connected indu tion loop 2 4 2 Switching the desired function on Use the AGC Limiter switch 24 to switch between AGC or Limiter function If...

Страница 8: ...y input to make sure that it is not possible to touch the priority input 2 8 Fault output You can send the condition of the loop amplifier to an external devices e g siren with the voltage free fault...

Страница 9: ...control 6 until the Limiter LED lights up Increase the electric current through the induction loop with the Power control 12 on the front of the amplifier Use the earphone jack 13 to listen directly a...

Страница 10: ...at s why we recommend that you use the services provided by HUMANTECHNIK We support architects technicians and installation ex perts qualified in the planning of LOS installations 3 3 Installation of...

Страница 11: ...has a greater resistance Connect the cable ends of the loop to the corresponding terminals 28 on the rear panel of the amplifier Make sure that you do not mix up the ends of the master and the slave c...

Страница 12: ...ing audiences 7 Check the average field strength by running diagonally over the induction loop area and determine the aver age of the values indicated The average value has to measure 0dB 3dB If you d...

Страница 13: ...nment and your health Material recycling also helps to reduce the use of raw materials Further information on recycling this pro duct is available from your community the municipal waste disposal depa...

Страница 14: ...info humantechnik com Tel 41 0 61 6 93 22 60 Fax 41 0 61 6 93 22 61 E mail info humantechnik com Tel 33 0 3 89 44 14 00 Fax 33 0 3 89 44 62 13 E mail sms audiofr com Hoorexpert BV Gildenstraat 30 NL...

Отзывы: