Monitoring mains power voltage
During operations the STERN monitors the mains power voltages. In case of
sudden loss of mains, the STERN shuts down all outputs to avoid harmfull noise
on the outputs due to the unexpected loss of mains power.
After a short drop-out of mains power you might read the warning '
Power
Failure
'. In this case press '
Power off
' on the front panel to continue. The
STERN will now enter stand-by mode. If the mains power is stable again you may
restart the STERN.
While switching on from stand-by mode and during operations the STERN also
monitors the level of mains power voltage. In case the mains power voltage level
is out of the permitted range during switching on or for a longer period during
operations (so that a secure operation of the unit is not longer ensured), the
STERN will shut down for security reasons issuing the warning '
Power Voltage
'.
Warning - Power Failure
Power Failure
Loss of mains power detected
Power Off