64
-
The following table is an overview on all detectable faults and their possible
causes:
Error
Possible causes
Overload
Short circuit or defect in loudspeaker.
DC
High level of DC voltage at the output:
defective preamplifier or source unit.
HF
High frequency oscillation: defective preamplifier.
Clipping: amplifier or preamplifier are overdriven.
Overtemperature HUMBOLDT is getting too hot. Cooling slots covered.
Pre Voltage
Fuse blown or different fault in power supply (pre voltage):
service case.
Amplifier Voltage
Fuse blown or different fault in power supply (amplifier volt-
age): service case
Power Voltage
Mains voltage is out of the permitted range of +/- 17% of
nominal mains voltage; the unit switches off for security rea-
sons or does not start up.
Power Failure
(Short) blackout of mains power.