background image

 

 

audionet 

DNC 

 

Digital Network Client 

User's Manual 

 

Содержание DNC

Страница 1: ...audionet DNC Digital Network Client User s Manual ...

Страница 2: ......

Страница 3: ...tput 14 5 3 Other connections 14 5 3 1 Network USB WLAN 14 5 3 2 USB Audio 15 5 3 3 FM Antenna Connection 15 5 3 4 Audionet Link 15 5 3 5 External power supply EPS G2 or EPX 16 5 3 6 Additional earth connection 17 5 3 7 Control connections 17 6 Usage 18 6 1 Basic operations 18 6 1 1 Powering up 18 6 1 2 Switching on and off 18 6 1 3 Mains phase detection 19 6 1 4 Using Audionet Link 20 6 1 5 Contr...

Страница 4: ...setup 34 8 2 1 Select Input 34 8 2 2 Display 35 8 2 3 Auto start 36 8 2 4 Power off mode 37 8 2 5 Channel name 38 8 2 6 Digital Equalizer 39 8 2 7 Digital equalizer setup 39 8 2 8 Trigger out 41 8 2 9 Speaker distance 42 8 3 Network setup 43 8 3 1 Manage Network 44 8 3 1 1 Restart Network Driver 44 8 3 1 2 Save Apply Settings 45 8 3 1 3 Load Factory Defaults 45 8 3 2 Connection Type 46 8 3 3 DHCP ...

Страница 5: ...6 Device info 63 9 Additional information 64 9 1 Glossary 64 9 2 Link collection 66 9 2 1 Wireless security 66 9 3 Equalizer filter type 67 9 3 1 Peak Filter 67 9 3 2 High shelf filter 67 9 3 3 Low shelf filter 67 9 3 4 High pass filter 2nd order 68 9 3 5 Low pass filter 2nd order 68 9 3 6 High pass filter 1st order 68 9 3 7 Low pass filter 1st order 68 9 4 Error handling FAQ 69 9 5 Security advic...

Страница 6: ......

Страница 7: ...nd They are unique creations designed to inspire musical enjoyment and have an ex cellent reputation amongst all connoisseurs throughout the world Each and every one of our precision manufactured devices is individually crafted at our Bochum works by our experienced and passionate work force But before you start listening to your new Audionet DNC please read this manual carefully so you are able t...

Страница 8: ...ction WLAN antenna Audionet Metal Remote Control RC 2 1 2 Transport Important Please transport the DNC only in the included package Always use the provided cloth bag to prevent scratches on the casing Please allow the DNC to adapt to the climatic conditions in your lis tening room before you switch on the unit for the first time after transport ...

Страница 9: ...9 2 Overview front panel power key A USB set key up key down key IR remote control receiver Display ...

Страница 10: ...t RS232 7 Trigger output 5 or 12 Volt 8 Audionet Link input IN 9 Audionet Link output OUT 10 Ethernet connector LAN 11 USB Audio Input 12 USB input 13 FM antenna input 14 Digital input no 3 AES EBU XLR 15 Digital input no 1 no 2 electrical 16 Balanced output XLR right 17 Unbalanced output Cinch right 18 Balanced output XLR left 19 Unbalanced output Cinch left 20 Digital input no 4 no 5 optical 21 ...

Страница 11: ... radiators Do not place the DNC on top of other units especially not on top of power amplifiers preamplifiers or similar devices that produce heat Both units could suffer damage from thermal overload Do not place other units on top of the DNC Both units could suffer damage from thermal overload Do not use the unit in places where it is exposed to vibrations Do not place the unit close to loudspeak...

Страница 12: ...r if massive trouble on the mains power grid is to be expected you should switch off the DNC from the mains using mains switch 1 Then to disconnect the unit com pletely from mains power grid pull the mains plug Tip The use of high quality mains cords can improve sound quality Ask your local dealer for more information 4 3 Orientation of mains plug The correct polarization of mains is important for...

Страница 13: ...IN 3 AES EBU 14 for connecting AES EBU input signals Note Please make sure that your digital sources provide only uncom pressed stereo PCM data to the digital inputs of your DNC Possibly other unsuitable formats e g Dolby Digital or DTS data streams etc could cause noise 5 1 1 1 Audionet HighBit input In order to send audio data across the Audionet HighBit interface to your DNC connect your source...

Страница 14: ... 16 and LINE OUT 17 for the right channel and BALANCED OUT 18 and LINE OUT 19 for the left channel 5 3 Other connections 5 3 1 Network USB WLAN The Ethernet port LAN 10 is a standard RJ45 socket for network cables Cat cable 10 100 Mbit BASE T The WLAN port WLAN 21 uses a SMA connection to attach the pro vided WLAN antenna With the articulated joint the antenna can be turned into two directions The...

Страница 15: ...he installation process all occurring security warnings can be confirmed with OK During the installation process your Audionet device has to be con nected with your PC via an USB cable After successful installation you can choose your DNC as the sound device playback device of your PC For configuration open the sys tem preferences of your PC Pay attention to the length of the USB cable If the cabl...

Страница 16: ... EPX In order to use the optional external power supply Audionet EPS G2 or Audionet EPX connect it with the delivered cable to socket EPS 5 on the back panel of your DNC Connect both units DNC and EPS G2 EPX to mains First switch on the DNC with the mains switch 1 on its back panel Then switch on the EPS EPX Now the DNC is ready to use stand by mode Switch on the DNC with the power key on the fron...

Страница 17: ...an additional and stable earth connection resulting in a better sound 5 3 7 Control connections Use trigger output TRIGGER 7 to control e g switch on off non Audionet devices If you switch on the DNC from stand by mode the trigger output 7 provides a signal of 12 Volts DC see section 8 2 8 Trigger out on page 41 which can be re configured to 5 Volts DC The serial connection RS232 6 is an additiona...

Страница 18: ...be expected e g thunderstorms it is recom mended to disconnect the DNC from the mains While the DNC is in stand by mode operate mains switch 1 on the back panel The display will go dark To disconnect the DNC from mains completely you have to pull the mains cord off the mains jack 2 Important Before you switch off the DNC from mains power down and dis charge completely all units connected to the ou...

Страница 19: ...witching on the unit from stand by mode by pressing the power key on the front panel the following mes sage will appear in the display in case the mains polarization is incorrect If you got the above message switch off the unit by pressing the power key Please wait until the display no longer reads Disconnect the DNC from mains by operating the mains switch 1 Now pull the mains plug and re insert ...

Страница 20: ...f other devices please wait until everything is in stand by mode before you switch on again Important For the DNC to be controlled via Audionet Link menu item Power off mode within the Global Setup menu has to be set to Quick Start see section 8 2 4 Power off mode on page 37 6 1 5 Control elements on the front panel The front panel has four keys to control the DNC see section 2 Overview front pane...

Страница 21: ...ct previous input channel see section 6 2 2 Input selection on page 25 or change an op tion of the setup menu see section 8 Device setup on page 32 up Push key to select next input channel see section 6 2 2 Input selection on page 25 or change an op tion of the setup menu see section 8 Device setup on page 32 ...

Страница 22: ...y Assignment RC 2 on page 29 You will need it es pecially for the NET input channel see section 6 2 1 3 NET input on page 23 The following illustrations demonstrate the differences between the input channels Your display could look different because of your selected system setup 6 2 1 1 Digital input channel 6 2 1 2 FM tuner WDR 2 FM FM Radio 99 20 MHz Frequency Input Channel name received signal ...

Страница 23: ...View 1 View 2 Folder icon Marker Media devices and internet radio Marker position Internetradio USB UPnP Server 1 of 4 Set No 7 NET Streaming In PCM 44 kHz Signal handling Equalizer Input EQ Channel name active User Setting ...

Страница 24: ...radio station WDR Event Track name mp3 128 kbps Play state Play Stop Pause Data type Title Interpreter Station text Station name Data rate Ludwig van Beethoven Für Elise WoO 59 mp3 00 00 01 Play time Album Play state Play Stop Pause Media type Title Interpreter ...

Страница 25: ...Stream USB Internet radio Network 10 12 21 7 USB USB Audio In USB Audio 11 8 FM FM Tuner FM Antenna 13 While switching of inputs the outputs are switched off at first Once an input is selected the outputs are switched on again Note Leave the input selection function by holding down the set key longer than 2 seconds or wait a few seconds Using the Audionet Metal Remote Control RC 2 switch to the ne...

Страница 26: ...m Internet Radio using the OK key Navigate to menu entry Get Access Code Confirm with OK You will find your access code consisting of eight digits in line 3 3 of 3 Write down this code and enter it in the registration window within your browser Important Once you obtained your access code using Audionet Metal Remote Control RC 2 write down the given code and put the remote control aside Proceed wi...

Страница 27: ...ne level back with the O key Alterna tively use function Virtual Streaming Client of RCP see manual RCP 6 2 4 3 UPnP server The easiest way to play music from an UPnP server is to use the software Audionet RCP the Android app aMM or the iOS app iMM Note Please have a look into separately available user s manual to our software Audionet RCP You will find it on our website www audionet de If you wan...

Страница 28: ...rol RC 2 Additionally you are able to control power on off volume muting and input channel selection of an Audionet preamplifier The following sections explain in detail the keys and their corresponding functions CHAN VOLU ƒ O audionet RC 2 CH DNx PRE 4 9 7 8 VOL ä 1 2 6 4 11 7 13 10 12 17 18 21 16 19 5 8 9 15 14 3 20 ...

Страница 29: ...e step to the left or selects previous option 12 for navigating through menus moves cursor one step to the right or selects previous option 13 for navigating through menus moves cursor one step downwards 14 OK acknowledge selection or enter menus folders 15 ä enter main menu to setup your system 16 O cancel current setup option get back to parent folder menu 17 CH select next input channel of Audi...

Страница 30: ...art ment 7 3 Settings for Audionet DNC Important The Audionet Metal Remote Control RC 2 is configured to control the DNC by factory default You do not have to perform any addi tional configurations For the sake of completeness the following section explains the correct setup for the DNC Depending on their type Audionet pre amplifiers use different system addresses for their remote control code A D...

Страница 31: ...on 19 or 16 according to the following table Audionet preamplifier Address PRE G2 PRE 1 G3 SAM G2 DNA DNP DNA 1 19 MAP 1 16 Note If not ordered explicitly the Audionet Metal Remote Control is pre configured to setting 19 of the DIP switch for the preamplifier Older models of Audionet preamplifiers use system address 16 Tip If you own an Audionet preamplifier that is not listed in the table above a...

Страница 32: ...lder up down are used to change parameters or select menu items For easier control use the directional keys on your Audionet Metal Re mote Control RC 2 see section 7 Audionet Metal Remote Control RC 2 on page 28 The most comfortable way to setup your DNC is to use our software Audionet RCP Use mouse and keyboard to adjust each parameter The computer display provides all information at a glance see...

Страница 33: ... and listen ing position Network Setup Manage Network Manage main network setup Connection Type Select type of connection DHCP Switch on off DHCP IP Address Setup IP address for your DNC IP Mask Setup subnet mask Gateway Setup gateway IP address DNS Setup DNS IP address RCP Port Setup network port for software Audionet RCP Wireless Setup Setup Wi Fi SSID security etc Factory Default Reset Reset Al...

Страница 34: ...n page 10 1 D1 Digital electrical Digital Inputs IN 1 15 2 D2 Digital electrical Digital Inputs IN 2 15 3 D3 Digital AES EBU Digital Inputs IN 3 14 4 D4 Digital optical Digital Inputs IN 5 20 5 D5 Digital optical Digital Inputs IN 6 20 6 NET Stream USB Internet radio Network 10 12 21 7 USB USB Audio In USB Audio 11 8 FM FM Tuner FM Antenna 13 While switching of inputs the outputs are switched off ...

Страница 35: ...ng active display saver the display shows only the number of the selected input channel e g D1 Digital In 1 The display brightness is always reduced to 25 and the location of the informa tion text will change randomly every 12 seconds to prevent any burn in effect of the display The display saver is deactivated and the display returns to its normal mode as soon as any user input is detected The us...

Страница 36: ... the key DNx on the Audionet Metal Re mote Control RC 2 to switch on the unit into normal op erating mode active The Auto Start function is active As soon as you connect the DNC to mains i e use the mains switch 1 on the back panel the unit starts up automatically to normal op erating mode Use this setting for timer controlled opera tions Tip For a more comfortable access use the directional keys ...

Страница 37: ...rk interface remains active and the DNC start up process is accelerated because the network interface does not need to boot up first Furthermore you can use soft ware Audionet RCP to power on If you select Quick Start mode the power consumption is increased For further details please see section 9 7 Specifications on page 72 Tip For a more comfortable access use the directional keys on the Audione...

Страница 38: ...keys of the Audionet Metal Remote Control RC 2 to alter the character marked by the cursor Press and hold set for longer than 2 seconds or press key to move the cursor one position to the right Key moves the cursor one position to the left To finish editing the channel name press set or OK Note For easier editing of the channel name use the software Audionet RCP see user s manual RCP All settings ...

Страница 39: ... Metal Remote Control RC 2 see section 7 Audionet Metal Remote Control RC 2 on page 28 Acknowledge your selec tion with the OK key 8 2 7 Digital equalizer setup The digital EQ is a parametric 5 band equalizer with separated adjust ment for left and right channel SET DIGITAL EQUALIZER Left EQ 1 Freq 120 HZ Q 8 00 Gain 3 0 dB Peak EQ Quality factor Frequency Gain Filter type Band selection EQ 1 5 Ma...

Страница 40: ...parameter Freq center respectively cutoff frequency depends on filter Q filter quality depends on filter Gain gain from 12 dB to 6 dB Filter type choose between seven different filter types Filter type Short description Peak EQ Band pass filter Hi Shelf Treble control Lo Shelf Bass control LP 2nd Low pass filter 2nd order HP 2nd High pass filter 2nd order LP 1st Low pass filter 1st order HP 1st Hi...

Страница 41: ...igured to 5 Volts DC Changing the voltage must be done by authorized personnel only Please ask your local dealer for support Note All settings apply to the currently selected input channel Tip For a more comfortable access use the directional keys on the Audionet Metal Remote Control RC 2 see section 7 Audionet Metal Remote Control RC 2 on page 28 Acknowledge your selec tion with the OK key SET TR...

Страница 42: ...ary delays of each channel to ensure that all signals from all speakers arrive at the same time at the listening position Tip For a more comfortable access use the directional keys and on the Audionet Metal Remote Control RC 2 see section 7 Audionet Metal Remote Control RC 2 on page 28 Acknowledge your selection with the OK key SET SPEAKER DISTANCES Left 0 cm Right 0 cm 1 of 2 Speaker distance lef...

Страница 43: ...ed by the cursor Press and hold set for longer than 2 seconds or press key to move the cursor one position to the right Key moves the cursor one position to the left To erase the character marked by the cursor use key O To finish editing press set or OK Note You will find a step by step example for network configuration at the end of the section see section 8 3 10 Example for Network setup on page...

Страница 44: ...cessary to restart the network driver of the DNC With this function you are able to restart the driver without having to switch off the device completely The driver restarts with its current settings Select this menu item and confirm your selection with set or OK The DNC issues the following message It takes about 30 seconds for the driver to restart Then your Audionet device will be available in ...

Страница 45: ...wired Ethernet connection with DHCP activated This way if you connect your device to a wired net work it should be ready to use Select this menu option and confirm your selection set or OK The DNC loads now the factory default settings After successfully loading the factory defaults the cursor automatically marks the menu item Save Apply Settings You must execute this menu item as described in sec...

Страница 46: ...avail able if you select Wireless WiFi 802 11 8 3 3 DHCP disabled DHCP client mode is disabled active Your DNC will try to get information via DHCP You do not need to setup the following menu items if the IP address is received from a DHCP server Menu item IP address IP mask gateway and DNS are without effect and they are overwritten by DHCP informa tion SET CONNECTION TYPE Wireless WiFi 802 11 Co...

Страница 47: ...4 IP Address Enter the fixed IP address you would like to assign to the DNC The IP address type is IPv4 e g 192 168 178 222 Tip Use the directional keys on your Audionet Metal Remote Control RC 2 Confirm everything with OK key Note Each block of an IP address consists of three digits Sometimes the triplets are not written down in full length i e the leading zeros are omitted For a valid IP address...

Страница 48: ...h OK key Note Each block of an IP address consists of three digits Sometimes the triplets are not written down in full length i e the leading zeros are omitted For a valid IP addresses you have to always enter all 3 dig its If necessary amend the leading zeros Example 0 1 10 100 has to be entered as 000 001 010 100 SET IP MASK 255 255 255 000 Subnet mask Title ...

Страница 49: ... block of an IP address consists of three digits Sometimes the triplets are not written down in full length i e the leading zeros are omitted For a valid IP addresses you have to always enter all 3 dig its If necessary amend the leading zeros Example 0 1 10 100 has to be entered as 000 001 010 100 8 3 7 DNS Setup your DNS IP address e g 192 168 178 001 SET DNS ADDRESS 192 168 178 001 DNS IP addres...

Страница 50: ...os Example 0 1 10 100 has to be entered as 000 001 010 100 8 3 8 RCP port Enter the port number for communication between DNC and the software Audionet RCP or Android app aMM or iOS app iMM If necessary you may adjust the port number in a range of 50000 to 59999 The factory default value is 54321 Changing the default value will only be necessary if this port number is already used in your network ...

Страница 51: ...th section 8 3 9 3 for further setup If you selected the old and less se cure method WEP then you have to adjust the settings in sections 8 3 9 4 to 8 3 9 6 Tip Alternatively you may use the software Audionet RCP for the Wire less setup For the time of configuration you need to connect your DNC to the network by wire Later you may disconnect the cable for using a Wi Fi connection Important For sec...

Страница 52: ...rase the character marked by the cursor use key O In this case the key O does not return to the parent menu To exit the SSID name setup without saving changes please press key ä 8 3 9 2 Wireless security Select your Wi Fi security method Please see the configuration of your router or access point which setting you need The security method of DNC and router access point has to be the same None no s...

Страница 53: ... access points security method WPA2PSK is referred to as WPA2PSK Personal or WPA2 Personal 8 3 9 3 WPA pass phrase Enter your WPA passphrase Please note that passphrase is case sensitive This menu item is only available is you selected WPAPSK or WPA2PSK for the security method Note Use keys up down on the front panel or keys of the Audionet Metal Remote Control RC 2 to alter the character marked b...

Страница 54: ...lect the WEP setup to your network open Open Authentication shared Shared Key Authentication Note Chose the authentication mode with the directional keys for open and for shared Confirm the adjustment with the OK key We strongly recommend using WPA2PSK standard to secure your Wi Fi connection WEP is not secure 8 3 9 5 WEP key index Select the Index Key 0 3 SET WEP INDEX KEY WEP Key Index 0 WEP ind...

Страница 55: ... set for longer than 2 seconds or press key to move the cursor one position to the right Key moves the cursor one position to the left To finish editing press set or OK To erase the character marked by the cursor use key O In this case the key O does not return to the parent menu To exit without saving changes please press key ä A WEP key contains only numbers 0 9 and letters a f Length of WEP key...

Страница 56: ...ection type with the keys Connection types Wired Ethernet and Wireless WiFi 802 11 are avail able Confirm with OK In this example we assume that you do not use DHCP in your network Therefore we disable the DHCP function and set a fixed IP address Open the menu item DHCP press the key to select disabled and confirm with OK key The DNC recognizes the new setting and switches back to the Network Setu...

Страница 57: ...ss set or OK Select the menu item IP Mask and compare the default settings with the data of your network The default value 255 255 255 000 is probably suitable for most of the home networks Confirm with OK Otherwise enter your settings as described above with IP address The gateway in your network is probably the router so you have to set the router s IP address as the gateway address Enter the co...

Страница 58: ...ings Confirm with OK The new created network profile with all its settings is now saved and will immediately be applied Wi Fi adjustment Go to menu Manage Network and select Connection Type Now change the setting to Wireless WiFi 802 11 and confirm with OK Menu item Wireless Setup is now available in the menu Net work Settings Now you have to enter the network name SSID and network security key If...

Страница 59: ...e OK key As the WEP mode is out of date and unsecure we only describe the setup of WPA2PSK security mode At last select menu item WPA Pass Phrase and enter your Wi Fi secu rity key Example 1x2y3z4a5b Confirm your input with OK Network settings are entered and ready to be saved and applied Save network profile Select Save Apply Settings from the menu item Manage Network and confirm with OK The new ...

Страница 60: ...erform a restart The individual menu items reset the following Reset All Settings reset of all settings except the settings of the network module This function com prises the menu items Reset EQ Set tings Reset User Settings and Reset FM Stations in one single function Reset EQ Settings reset all settings of the digital equalizer Reset User Settings reset all User Settings 1 to 20 Reset Network Mo...

Страница 61: ... EQ adjustments for all channels complete speaker setup volume offsets etc Example for usage Set EQ to reduce amount of low frequencies and store it under the name of night mode In normal operation mode the display informs about the currently active User Settings Note If no user setting is selected for current input channel the display space for the active User Setting will be empty If you load a ...

Страница 62: ...e If you save to a user setting all existing data will be overwritten If you do not want to do the complete setup again copy the desired user setting to a different slot and refine the settings if necessary For that purpose load the existing user setting and store it to a different memory slot 8 5 2 Load user setting Open the system menu with key ä on the Audionet Metal Remote Con trol RC 2 or pus...

Страница 63: ...ersion Boot loader version Proceed to the second page by pressing the set or OK The sec ond page contains the following information Connection Type DHCP adjustment IP Address of the device Device Info Device DNC MAC 1F 2E 3D 4C 5B 6A FW 01 02 0012 BL 00 08 NETWORK STATUS Wired Ethernet DHCP IP 192 168 178 222 ...

Страница 64: ...nection between LAN and WAN Nowadays all devices mentioned above are built in one device which is called router IP Address The IP Address identifies a device in the network It is comparable to a postal address An IP address can only be used once within a network IPv4 192 168 0 1 common standard IPv6 2001 db8 1428 57ab future standard DNS Server A DNS Server translates textual request to IP address...

Страница 65: ...on it NAS Network Attached Storage A NAS is a network storage device which makes data e g music pic tures video and documents easily accessible to all network devices UPnP MS Universal Plug and Play Media Server UPnP is a defined network standard to connect clients and servers It is very easy to use because you do not have to set up a lot Only connect and play UPnP media servers are the most commo...

Страница 66: ...oks in wiki article 9 2 1 Wireless security WPA http en wikipedia org wiki Wi Fi_Protected_Access WPA2 http en wikipedia org wiki Wi Fi_Protected_Access WPA2 PSK http en wikipedia org wiki Pre shared_key EAP Radius http en wikipedia org wiki RADIUS http en wikipedia org wiki Extensible_Authentication_Protocol WEP http en wikipedia org wiki Wired_Equivalent_Privacy ...

Страница 67: ... referenced science books in the wiki article 9 3 1 Peak Filter Gain range 12 dB to 6 dB Frequency range 20 to 20000 Hz Filter quality Q 0 3 8 0 Wikipedia en wikipedia org wiki Band pass_filter 9 3 2 High shelf filter Gain range 12 dB to 6 dB Frequency range 20 to 20000 Hz Wikipedia en wikipedia org wiki Equalization_ audio Shelving_filter 9 3 3 Low shelf filter Gain range 12 dB to 6 dB Frequency ...

Страница 68: ...ipedia en wikipedia org wiki High pass_filter 9 3 6 High pass filter 1st order Attenuation at set Frequency 3 dB Attenuation below the set frequency is 20 dB per decade Wikipedia en wikipedia org wiki High pass_filter 9 3 7 Low pass filter 1st order Attenuation at set Frequency 3 dB Attenuation above the set frequency is 20 dB per decade Wikipedia en wikipedia org wiki High pass_filter 1 Note Tech...

Страница 69: ...ou switch on again If there is still a problem contact your local dealer for support Which control has no function If the remote control does not react try the front panel keys maybe it is only a problem of the remote control Remote control has no function Please check the batteries first and replace them if necessary Please check the position of the DIP switches see section 7 3 Settings for Audio...

Страница 70: ...n the case Unauthorized opening will cause loss of guar antee Prevent short circuit to the outputs Switch off all devices if you plug any cable Use a dry cloth for cleaning If massive trouble on the mains power grid is to be expected Discon nect all devices from mains to prevent electrical overload Disconnect antenna and network connections as well We would like to wish you many exciting listening...

Страница 71: ...metrical digital EQ for all input channel Gain All channel all MPEs 0 dB Q All channel all MPEs 1 00 Freq 50 207 725 3147 10413 Hz Network Setup DHCP active IP Address 192 168 178 222 IP Mask 255 255 255 000 Gateway 192 168 178 001 DNS 192 168 178 001 RCP Port 54321 Wireless Setup SSID blank Wireless Security WPA2PSK WPA Cipher Type AES WPA Pass Phrase blank WEP Authentication open WEP Key Index 0...

Страница 72: ...onnector WLAN 1 Audionet Link optical Output 1 pair RCA jack gold plated Teflon isolated 1 pair XLR symmetric gold plated Neutrik 1 Audionet Link optical 1 3 5mm TSR connector mono Trigger Out 12V 5V 50mA max 1 Sub D9 Serial interface RS232 Mains 220 V 240 V 50 60 Hz Power consumption 1 W Stand by max 85 W Dimensions width 430 mm height 70 mm depth 310 mm Weight 8 kg Design Front brushed aluminum ...

Страница 73: ...th software automatic mains phase detection separated power supply for digital and analog section fully DC coupled no condenser in signal path Audionet Link in output to remote control Audio net devices Options External power supply Audionet EPS G2 or Audio net EPX ...

Страница 74: ...ications and design are subject to changes without prior notice audionet is a trademark of Idektron GmbH Co KG Engineered and produced by Idektron GmbH Co KG Herner Str 299 Gebäude 6 44809 Bochum Germany www audionet de kontakt audionet de ...

Отзывы: