Operating 

6.1  Powering up 

First  of  all,  please  make  sure  your  AMP1 V2  is  connected  correctly  to 
your  pre-amplifier,  speakers  and  mains  (see  section  '

Installation  and 

power supply

' on page 8 and section '

Inputs and outputs

' on page 10). 

The AMP1 V2 is a stand-by unit. As soon as the amplifier is connected to 
the mains, the unit is in stand-by mode 

 

Only in cases of extended absence (like vacations) or if massive trouble 
on the mains power is to be expected it is recommended to disconnect the 
AMP1 V2 from mains. 

 

 

Important

 

·

 

Never  pull  the  mains  cord  while  the  AMP1 V2  is  switched  on! 
Before you pull the mains plug, power down the unit to stand-by 
mode first. 

 

 

6.2  Switching on/off 

To power up the AMP1 V2 from stand-by mode, press the 

power

 key on 

the front panel. Now the AMP1 V2 is in normal operating mode. 

If you would like to switch off the unit, please press the 

power

 key on the 

front panel. 

 

 

Note 

·

 

If  'remote  controlling'  via  Audionet-link  is  used,  after  switching  off 
the  AMP1 V2  is  always  in  stand-by  operation  with  low  power  con-
sumption.  Only  in  case  of  longer  absence  the  AMP1 V2  should  be 
disconnected from the power supply (mains unplugged). 

 

 

6.3  Using Audionet Link 

If your AMP1 V2 is connected to an Audionet pre amplifier via Audionet 
Link, use the remote control of the pre amplifier to automatically switch 
on/off  the  AMP1 V2  (and  all  other  Audionet  units  also  connected  via 
Audionet Link). 

For setting up the necessary connections please refer to section '

Audionet 

Link

' on page 12. 

 

Содержание AMP 1 V2

Страница 1: ...1 Stereo Amplifier User s Manual...

Страница 2: ...2...

Страница 3: ...1 Placement 8 4 2 Mains connection 8 5 Inputs and outputs 10 5 1 Inputs 10 5 2 Speaker terminals 10 5 3 Bi Wiring 11 5 4 Bridged operation 11 5 5 Audionet Link 12 6 Operating 13 6 1 Powering up 13 6 2...

Страница 4: ...and long life stability This system is designed for absolute natural music reproduction The following will give you all information about how to operate your AMP1 V2 Please read this carefully before...

Страница 5: ...tly reading one standard mains cord 1 2 Transport Important Please transport the AMP1 V2 only in the included package Always use the plastic bag to prevent scratches on the housing Please allow the AM...

Страница 6: ...6 2 Overview control elements 2 1 Front panel power key...

Страница 7: ...nnections 3 1 Back panel 1 2 3 6 7 8 5 Mains input 6 Marking Mains phase 7 Speaker terminal left 8 Line RCA input left 1 Line RCA input right 2 Speaker terminal right 3 Audionet Link input 4 Audionet...

Страница 8: ...ciently ventilated to allow the heat to dissipate Do not expose the unit to direct sunlight or in close range to heat sources like radiators or fan heaters Do not cover the ventilation slots of the un...

Страница 9: ...ly in cases of extended absence like vacations or if massive trouble on the mains power is to be expected you should remove the AMP1 V2 form the mains To disconnect the unit completely from mains pull...

Страница 10: ...e right 1 and left input 8 of the AMP1 V2 to the cor responding outputs of your pre amplifier 5 2 Speaker terminals Connect your speakers to the gold plated terminals 2 and 7 on the back panel of the...

Страница 11: ...speaker For that the output signal of the pre amplifier must be avail able in inverted form additionally e g use the Audionet PRE G2 For the left channel now please do the following Connect the normal...

Страница 12: ...of the AMP1 V2 In case you would like to automatically switch on off further Audionet units in your system e g a second AMP1 V2 using the Audionet Link interface please connect the Audionet Link outpu...

Страница 13: ...by mode first 6 2 Switching on off To power up the AMP1 V2 from stand by mode press the power key on the front panel Now the AMP1 V2 is in normal operating mode If you would like to switch off the uni...

Страница 14: ...h code of the LED next to the power key on the front panel Error Code Possible Cause short short short overload left channel short short long overload right channel short long short overheat left chan...

Страница 15: ...vely optimised Negative magnetic and electric influence and interaction between input decoupling and power section are reduced to a residual minimum 8 2 Power supply The input sections are supplied by...

Страница 16: ...t in a dry room at a reasonable room tem perature Avoid moisture or any liquid to get into the unit Set up the unit in a free position so that the air is allowed to flow through the unit slits Do not...

Страница 17: ...120 dB 25 Watt into 4 Ohm k3 typ 123 dB 25 Watt into 4 Ohm SNR 106 dB 10 Veff Inputs 2 WBT RCA line gold plated 1 Audionet Link optical Input impedance 37 kOhm 220 pF Outputs 2 pair WBT NextGen jacks...

Страница 18: ...pulse stable high current capacitors with filtering capacity totalling 188 000 uF discrete extremely fast and stable driver and output stages control unit for HF DC temperature rise and overload remot...

Отзывы: