Troubleshooting
24
6 Troubleshooting
Troubleshooting may only be performed by authorised
maintenance personnel.
In the event of a malfunction, always pull the plug from the socket
before attempting to solve the problem.
If the problem cannot be solved using the below troubleshooting
table, please contact your dealer or Audion.
Problem
Cause
Solution
The sealer will not
switch on.
The plug is not, or not
properly, connected to
the socket.
Put the plug properly in
the socket.
The power supply is out
of order.
Check the power sup-
ply.
The fuse has blown.
Replace the fuse.
Internal malfunction.
Contact your dealer or
Audion.
The sealer is not trans-
porting the bags prop-
erly.
The PTFE glass-fibre
belts are defective.
Check the PTFE glass-
fibre belts and replace if
necessary.
The motor has been
switched off.
Check the operating set-
tings and switch on the
motor if necessary.
Internal malfunction.
Contact your dealer or
Audion.
The sealer is not heating
up.
The sealing tempera-
ture has been set too
low.
Check the sealing tem-
perature setting and
increase if necessary.
The heater has been
switched off.
Check the operating set-
tings and switch on the
heater if necessary.
Internal malfunction.
Contact your dealer or
Audion.
Содержание D541
Страница 1: ...Continuous sealer D541 D541 ENG Rev 01 User manual www audion com...
Страница 36: ...Electrical Diagram 36 0 1 2 3 3 2 0 1 2 2 1 3 0 2 4 1 5 3 1 0 1 6 7 3 1 1 6 8 3 1 6 7 3 9 3...
Страница 39: ...Continuous sealer D541 Spare parts 39 A3 3 Exploded view A B B B B...
Страница 43: ......