Continuous Sealer
D 552 AVT
Operation
21
5.1.3 Switching on the heating, the cooling and the blower
Switch on the heating, the cooling and the blower as follows:
5. Press the
PROG
button until the actual
sealing temperature is once again shown
in the display.
The
T
EMP
led will blink if the set
temperature deviates more than
5°C from the actual sealing
temperature.
Make a number of trial seals and, if
necessary, readjust the sealing
temperature and speed.
1. Press the H
EAT
button.
2. Press the M
OTOR
button.
The heating and transport motor
must always be switched on before
use.
3. If necessary, press the F
AN
button.
If a paper or aluminium-laminate
film is used, the F
AN
(blower) does
not have to be switched on.
Make sure to switch on the blower,
however, when using PE film types.
5