16
Inquiry Commands
mute?
Returns which zones are
muted
unmute?
Returns which zones are
unmuted
bus1?
Returns which zones are
switched to bus#1
bus2?
Returns which zones are
switched to bus #2
local?
Returns which zones are
switched to local input
signalsource?
Returns a list showing for
each zone what is its source
Example:
1,3,2,3,3,1,1,2 where 1 is
Bus #1 and 3 is Local
temp?
Returns a value for each
zone where cool is 1, warm is
2 and hot is 3
power?
On is 1 and off is 0 (zero)
acvoltage?
Responses are; 1 is low, 2 is
normal and 3 is high
protection?
For each zone, the responses
are: 1 is normal, 2 is muted,
3 is protect and 4 is short
circuit
signalsense?
On is 1 and off is 0 (zero)
timeout?
Number of seconds before
inactive session terminated
bypass?
Physical bypass switch en
-
gaged is 1, 0 is not engaged
log?
Protection data log - see
below
Memory?
Responds with 0, 1, 2, 3
where 0 is the current
configuration, not a saved
memory
Internet
Connectivity and
Control
Содержание The Director D3400
Страница 22: ... 18 Hook Up Guide System Diagrams Using Bus Inputs to Create Larger Zones ...
Страница 41: ...TheDirector Model D3400 Model D4400 Installer s Guide 37 Block Diagram ...
Страница 43: ......