SA-3051/SA-3052 Operation Manual
WARNING:
Exposure to sound pressure levels in excess of 90 decibels causes hearing damage.
AudioControl Industrial assumes no liability or responsibility for hearing loss
incurred directly or indirectly by the use of the SA-3051/SA-3052. Please remember to
practice safe sound.
Lo Range
Hi Range
70dB
110dB
80dB
120dB
90dB
130dB
100dB
140dB
110dB
150dB
120dB
160dB
Getting extreme at 175dB SPL
Input Sensitivity Scale Conversion
Figure 3.5
CM-10 microphone
SPL-175 microphone
The standard SA-3051/SA-3052 measures sound pressure levels up to 136dB. The SPL-175 option
includes a high SPL microphone to allow measurements from 100 to SPL-175. The high SPL mode only
works in the digital SPL display mode. Don’t use the SPL-175 microphone for RTA measurements.
Selecting the SPL operating mode is very simple.
1. Press and hold the
Spl
button to enter the digital SPL mode.
2. The display will alternate HI and LO. Release the
Spl
button when the appropriate mode is displayed.
3. When the digital SPL mode is in the HI range, a single LED will stay lit at the left edge of the display.
Figure 3.6 SA-3051/SA-3052 display showing HI SPL mode
Figure 3.7 HI SPL conversion scale
Hi Range
Indicator
To install the AC-10:
1. Unplug the CM-10 microphone from the mike cable.
2. Plug the AC-10 onto the end of the mike cable.
3. Plug the CM-10 into the AC-10.
4. Select the appropriate weighting curve with the
a/C
SliDE
SwitCh
on the AC-10.
3-6
figure 3.4 AC-10 weighting filter