background image

 

|

 

P a g e

 

 

 

Cabling the Device to Power 

The device can be powered from a standard alternating current (AC) electrical wall outlet or a DC power 

source. 

1.

 

GROUNDING:

 Ground (earth) the device by inserting an electrically earthed strap of 16-AWG 

(minimum) wire in to grounding lug (supplied), and then attaching the lug to the chassis using the two 

screws and spring washers. For more information, refer to the device's 

Hardware Manual

. Connect the 

other end of the strap to protective earthing. This must be in accordance with regulations enforced in 

the country of installation. 

 

2.

 

AC POWER:

 

For each AC power model, connect the line socket of the AC power cord (supplied) to the 

device's AC power inlet, located on the rear panel. Connect the plug at the other end of the AC power 

cord to a standard electrical wall outlet. 

 

 

 

Содержание MediaPack 1288

Страница 1: ...nd Hardware Manual respectively which can be downloaded from AudioCodes website at https www audiocodes com library technical documents Before you begin please read the Safety Precautions on page 9 Pa...

Страница 2: ...mal device and FXS blade operation Orange On At least one DSP has reached high temperature threshold Red On Initial power up stage or Failure detected in at least one FXS blade or No FXS blade detecte...

Страница 3: ...Supply module s fan is operating normally Orange Flashing Connected to power source but chassis not receiving power or fault detected in Power Supply module s fan If only one of the Power Supply modu...

Страница 4: ...rackets are flush against the front rack posts and that the holes of the front mounting brackets are aligned with the holes on the front rack post 4 Hold the chassis in position while the second perso...

Страница 5: ...e lug to the chassis using the two screws and spring washers For more information refer to the device s Hardware Manual Connect the other end of the strap to protective earthing This must be in accord...

Страница 6: ...to the DC terminal block plug supplied making sure that the wires are inserted in to the correct openings on the terminal block according to their polarity negative or positive Insert the DC terminal...

Страница 7: ...t cable connect any one of Ethernet ports of the CPU module rear panel to the LAN port of your computer 2 Change the IP settings of your computer to correspond with the device s default IP address and...

Страница 8: ...ace s toolbar click the Save button the new IP address is now saved to the device s flash memory 10 Re cable the device to the required network You can now access the device s management interfaces re...

Страница 9: ...the building additional protection usually a 350V three electrode Gas Discharge Tube GDT as described in ITU T K 44 must be provided at the entry point of the telecom wires into the building usually...

Страница 10: ...en Street Airport City Lod 7019900 Israel Tel 972 3 976 4000 Fax 972 3 976 4040 AudioCodes Inc 200 Cottontail Lane Suite A101E Somerset NJ 08873 Tel 1 732 469 0880 Fax 1 732 469 2298 Contact us https...

Отзывы: