Safety Precautions 

 

This device is an indoor unit and therefore, must not be installed outdoors.  

 

Ethernet cabling must be routed only indoors and must not exit the building. 

 

The device must be installed and serviced only by qualified service personnel. 

 

Do not open or dismantle the device.  

 

Do not expose the device to water or moisture. 

 

Make sure the device is installed in a well-ventilated location to avoid over heating of internal 

components and subsequent damage. 

 

Do not place any object on top of the device and make sure that sufficient clearance from the top and 

sides are maintained to ensure proper airflow to avoid over heating of internal components. 

 

Operate the device in an ambient temperature (Tma) that does not exceed 40°C (104°F).  

 

The device must be installed only in restricted access locations. 

 

The device must be connected permanently to earth via the screw terminal, located on the device's 

rear panel, as per the instructions in the device's 

Hardware Installation Manual

 

The grounding connection must not be removed unless all FXS lines are first disconnected from the 

device. 

 

Installation of the device must be in accordance with national electrical codes and conform to local 

regulations.  

 

AC Power: Use only the supplied AC power cord for connection to the power source. 

 

AC Power: Connect the device to an electrical socket outlet that provides protective earthing 

(grounding). 

 

DC Power: Connect the device to a safety extra-low voltage (SELV) source that is sufficiently isolated 

from the mains. 

 

The device is immune against power surge levels of up to 1 Kilovolts (KV) as required by the following 

standards: IEC 61000-4-5, EN 55024, and EN 300386. Power surges above protection levels as required 

by EN 55024 and EN 300386 may cause damage to the device.  

 

The device includes an integrated secondary surge protection, but does not include primary telecom 

protection. To comply with ITU-K.21 requirements when the telephone lines are routed outside the 

building, it is essential to install additional protection using a three-electrode Gas Discharge Tube (GDT) 

rated 350V as a primary protection on the MDF, located at the entrance point of telephone wiring to 

the building. The center pin of the GDT must be connected to ground. 

 

For FXS ports, use minimum 26-AWG wiring if it exits the building. 

 

 

 

Содержание MediaPack 124

Страница 1: ...nd Hardware Installation Manual respectively which can be downloaded from AudioCodes website at https www audiocodes com library technical documents Before you begin please read the Safety Precautions...

Страница 2: ...ringing Red On Line malfunction SRTP is enabled and device resources DSPs are currently unavailable for calls on these ports their resources are borrowed for SRTP functionality This LED state applies...

Страница 3: ...ults Disconnect the Ethernet cable and then with a paper clip or any other similar pointed object press and hold down the button for at least 12 seconds but no more than 25 seconds Mounting the Device...

Страница 4: ...ated on one end of the AC power cord supplied into the device s AC power socket located on the rear panel Insert the male plug that is located on the other end of the AC power cord into a standard ele...

Страница 5: ...a crossover RJ 45 Ethernet cable connect the device s Ethernet port that is located on the rear panel and labeled ETHERNET to the LAN port of your computer 2 Change the IP address of your computer to...

Страница 6: ...Gateway in dotted decimal notation 7 Click Submit to apply your settings 8 Open the Maintenance Actions page Maintenance tab Maintenance menu Maintenance Actions and then click BURN to save your sett...

Страница 7: ...FXS lines are first disconnected from the device Installation of the device must be in accordance with national electrical codes and conform to local regulations AC Power Use only the supplied AC powe...

Страница 8: ...treet Airport City Lod 7019900 Israel Tel 972 3 976 4000 Fax 972 3 976 4040 AudioCodes Inc 200 Cottontail Lane Suite A101E Somerset NJ 08873 Tel 1 732 469 0880 Fax 1 732 469 2298 Contact us https www...

Отзывы: