background image

Hardware Installation Manual

AudioCodes Gateway & Session Border Controller Series

Mediant 800 Gateway
and E-SBC

Version 7.2

Содержание Mediant 800B

Страница 1: ...Hardware Installation Manual AudioCodes Gateway Session Border Controller Series Mediant 800 Gateway and E SBC Version 7 2 ...

Страница 2: ...s product Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner For more information on how to buy technical support for AudioCodes products and for contact information please visit our website at https www audiocodes com services support maintenance and support Documentation Feedback AudioCodes continually strives to pro...

Страница 3: ...servicing Open source software may have been added and or amended for this product For further information please visit our website at https www audiocodes com services support open source or contact your AudioCodes sales representative Related Documentation Document Name SBC Gateway Series Release Notes for Latest Release Versions SBC Gateway Series Release Notes for Long Term Support Versions Ga...

Страница 4: ...fallback updated 10684 Lifeline splitter cable not supplied 10685 Wall mounting added Mediant 800C added Mediant 800A removed logos updated CENTOS removed 10687 Power fuse updated AC power rating updated warnings added for grounding cable type for LAN updated 10688 PRI PSTN fallback hardware note updated OSN driver download note removed 10689 Logo updated on front panel 10690 Mediant 800C rear pan...

Страница 5: ... Installed Rack Shelf 13 Using Mounting Brackets 13 5 Cabling the Device 15 Grounding and Surge Protection 15 Connecting to LAN 16 Connecting to Analog Devices 18 Connecting the FXS Interfaces 18 Connecting the FXO Interfaces 19 Connecting the FXS Analog Lifeline 20 ISDN BRI Interfaces 21 Connecting to BRI Lines 21 Connecting PSTN Fallback for BRI Lines 22 Connecting ISDN E1 T1 Interfaces 23 Conne...

Страница 6: ...t Ethernet ports These ports operate in port pair redundancy providing up to 6 port pair groups Open Solutions Network OSN server platform for hosting third party applications such as an IP PBX Power Mediant 800B Single AC power inlet Mediant 800C Single AC power inlet and a DC power inlet optional customer ordered Mediant 800 includes two hardware revisions which differ as follows Mediant 800B Ma...

Страница 7: ...the chassis from the carton 3 Check that there is no equipment damage 4 Ensure that in addition to the chassis the package contains the following items Four anti slide bumpers for desktop installation Two mounting brackets for 19 inch rack mounting One AC power cord Mediant 800C only one AC DC power adaptor optional separate orderable item 5 Check retain and process any documents If there are any ...

Страница 8: ...ronment Physical Specification Description Dimensions H x W x D 1U x 32 x 34 5 cm 12 6 x 13 6 inches Weight 2 5 kg 5 5 lbs Environmental Operational 5 to 40 C 41 to 104 F Storage 25 to 85 C 13 to 185 F Humidity 10 to 90 non condensing Front Panel Description The front panel provides the telephony port interfaces various networking ports reset pinhole button and LEDs Ports and Buttons The device s ...

Страница 9: ...ase T Gigabit Ethernet LAN ports for connecting IP phones computers or switches These ports support the following features 1 1 LAN port redundancy These ports are grouped in pairs where one port is active and the other redundant When a failure occurs in the active port a switchover is done to the redundant port Half and full duplex modes Auto negotiation Straight or crossover cable detection 4 FE ...

Страница 10: ...he following table Table 3 3 LAN LEDs Description LED Color LED State Description Green On Ethernet link established Flashing Data is being received or transmitted Off No Ethernet link FXS LEDs Each FXS port provides a LED for indicating operating status as described in the following table Table 3 4 FXS LEDs Description LED Color LED State Description Green On Phone is off hooked Flashing Rings th...

Страница 11: ...ription Color State Description Green On Physical layer Layer 1 is synchronized normal operation Red On Physical layer Layer 1 is not synchronized Off Trunk is not active E1 T1 PRI LEDs Each trunk port provides a LED for indicating operating status as described in the following table Table 3 7 E1 T1 LEDs Description Color State Description Green On Trunk is synchronized normal operation Red On Los...

Страница 12: ...re Off Advanced rebooting stage Power LEDs The power LEDs depend on the Mediant 800 model Power LED The POWER LED indicates the power supply status as described in the following table Table 3 9 POWER LED Description LED Color LED State Description Green On Power is received by the device Off No power received by the device The POWER LED is applicable only to Mediant 800B AC PWR LED The AC PWR LED ...

Страница 13: ...he subsequent table Figure 3 3 Mediant 800B Rear Panel Figure 3 4 Mediant 800C Rear Panel The figures above are used only as an example The Open Network Solution OSN server ports are a customer ordered item and depend on the ordered OSN server platform Table 3 12 Rear Panel Description Item Label Description 1 OSN USB Three USB ports Standard A type for connecting computer peripherals e g mouse an...

Страница 14: ...mple one port can be connected to the LAN to IP Phones and the second port to the WAN interface to an IP PBX Note The number of ports depends on ordered OSN server platform see Connecting the OSN Server on page 26 5 Protective earthing screw 6 Mediant 800B 100 240V 4A 50 60Hz Mediant 800C 100 240V 1 5A 50 60Hz 3 Prong AC power supply entry 7 DC IN 12V 10A DC power inlet for accepting a DC terminal...

Страница 15: ...our anti slide bumpers supplied are attached to the underside of the device To attach the anti slide rubber bumpers to the device 1 Flip the device over so that its underside faces up 2 Locate the four anti slide grooves on the underside one in each corner 3 Peel off the adhesive anti slide rubber feet and stick one in each anti slide groove Figure 4 1 Rubber Foot Attached to Underside of Device 4...

Страница 16: ...sure that the orientation of the chassis is correct front panel facing up toward the ceiling Make sure that the chassis is horizontal with the floor you can use a level With a pencil stencil the mounting brackets keyholes on the wall 3 Remove the chassis and place it on a horizontal surface 4 Drill holes in the wall where you marked the keyholes 5 Insert wall anchors not supplied of appropriate si...

Страница 17: ... can be installed in a standard 19 inch rack by implementing one of the following mounting methods Placing it on a pre installed shelf in a 19 inch rack see Using a Pre Installed Rack Shelf on the next page Attaching it directly to the rack s frame using the device s mounting brackets supplied that need to be attached to the chassis see Using Mounting Brackets on the next page 12 ...

Страница 18: ...ring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips For earthing the device see Grounding and Surge Protection on page 15 Using ...

Страница 19: ...tion Manual Figure 4 5 Attaching the Mounting Brackets 2 Place the device on a pre installed shelf in the rack 3 Attach the ends of the mounting brackets that you installed in Step 1 to the vertical track of the rack s frame using standard 19 inch rack bolts not supplied 14 ...

Страница 20: ...allation site using a wire of 6 mm2 surface wire If the device is installed in a rack with other equipment the rack must be connected to the equipotential grounding bus bar of the Telecommunication room using a stranded cable with surface area of 25 mm2 The length of this cable must be as short as possible no longer than 3 meters The device does not include primary telecom protection When the FXO ...

Страница 21: ...sing a 6 32 UNC screw Figure 5 1 Grounding the Device 2 Connect the other end of the strap to a protective earthing This should be in accordance with the regulations enforced in the country of installation Connecting to LAN The device provides up to four 10 100 1000Base T Gigabit Ethernet RJ 45 ports and up to eight 10 100Base TX Fast Ethernet RJ 45 ports for connection to the LAN These Ethernet p...

Страница 22: ...raight through Connector Type RJ 45 Connector Pinouts Table 5 1 RJ 45 Connector Pinouts for GbE FE Pin Signal Name 1 Ethernet signal pair 10 100 1000Base T 2 3 Ethernet signal pair 10 100 1000Base T 6 4 Ethernet signal pair 1000Base T 5 7 Ethernet signal pair 1000Base T 8 Shield Chassis ground To connect the device to the LAN 1 Connect the RJ 45 connector on one end of the Ethernet cable to one of...

Страница 23: ...ected to the appropriate external devices otherwise damage to the device may occur FXS ports are considered TNV 2 FXS interfaces are a separate orderable item FXS is the interface replacing the Exchange i e the CO or the PBX and connects to analog telephones dial up modems and fax machines The FXS is designed to supply line voltage and ringing current to these telephone devices An FXS VoIP device ...

Страница 24: ...center pin of the GDT MDF grounding bar must be connected to the equipotential grounding bus bar of the Telecommunication room To protect against electrical shock and fire use a minimum 26 AWG wire to connect FXO ports to the PSTN Ensure that the FXO ports are connected to the appropriate external devices otherwise damage to the device may occur FXO ports are considered TNV 3 FXO interfaces are a ...

Страница 25: ...log POTS phone and the PSTN PBX using a splitter cable not supplied The Lifeline splitter connects pins 1 and 4 to another source of an FXS port and pins 2 and 3 to the POTS phone The lifeline splitter cable is a separate orderable item Analog Lifeline cabling is applicable only if the device is ordered with FXS interfaces The number of supported Lifelines depends on the device s hardware configur...

Страница 26: ... side TE or network termination network side NT Up to eight terminal equipment TE devices can be connected per BRI S T port using an ISDN S bus that provides eight ISDN ports When configured as NT the BRI port drives a nominal voltage of 38 V with limited current supply of up to 100 mA BRI port cabling must be routed only indoors and must not exit the building To protect against electrical shock a...

Страница 27: ...ach BRI module provides two or four spans In the event of a PSTN fallback the BRI module s metallic relay switch automatically connects line Port 1 I to Port 2 II of the BRI module For example if a PBX trunk is connected to Port 1 and the PSTN network is connected to Port 2 when PSTN Fallback is activated calls from the PBX are routed directly to the PSTN through Port 2 BRI port cabling must be ro...

Страница 28: ...ribes the cabling of the device s E1 T1 PRI trunk interfaces PRI port cabling must be routed only indoors and must not exit the building To protect against electrical shock and fire use a 26 AWG min wire to connect T1 or E1 ports to the PSTN To comply with EMC rules and regulations use shielded twisted pair STP cables for E1 interfaces PRI interfaces are a separate orderable item Cable specificati...

Страница 29: ...ute calls between the Tel and PSTN side Mediant 800C In the event of a PSTN fallback the module s metallic relay switch automatically connects Port 1 with Port 2 and Port 3 with Port 4 for the four E1 T1 port module to route calls between the Tel and PSTN side These ports must be on the same module PRI port cabling must be routed only indoors and must not exit the building To protect against elect...

Страница 30: ...r for Serial Communication The device provides an RS 232 serial interface port on its front panel for serial communication with a PC Cable specifications Connector Type RJ 45 Cable RJ 45 to DB 9 cable adaptor To connect the device s serial interface to a computer 1 Connect the RJ 45 cable connector to the device s serial port labeled CONSOLE 2 Connect the other end of the cable to the COM1 or COM2...

Страница 31: ...erver platforms Table 5 3 OSN Server Platforms OSN Platform CPU Memory Storage Interfaces OSN2 2nd Generation Intel Core Celeron 1 6 GHz 2 or 4 GB HDD 500 GB Two external Gigabit Ethernet Internal Gigabit Ethernet Three USB 2 0 via Connection Module VGA OSN4 3rd Generation Intel Core i7 Quad Core 16 GB ECC DDR3 HDD 500 GB or SSD 240 GB Two external Gigabit Ethernet Internal Gigabit Ethernet Three ...

Страница 32: ...SN server 1 Perform the following cabling procedures on the OSN server located on the rear panel a Connect computer peripherals e g mouse and keyboard to the USB ports Standard A type labeled USB b Connect the USB storage device containing the operating system installation files Linux or Microsoft Windows to one of the USB ports labeled USB c Connect a monitor using a 15 Pin D type male connector ...

Страница 33: ...ical Specification Value Input Voltage Single universal AC power supply 100 to 240V AC Input Frequency 50 to 60 Hz AC Input Current Mediant 800B 4 A max Mediant 800C 1 5 A max Max Power Consumption SBC Only no PSTN 27W Gateway without OSN 60W Power consumption varies according to the assembled hardware configuration The device must be connected to a socket outlet providing a protective earthing co...

Страница 34: ...below DC power support is a separate orderable item When both power supplies are used AC and DC the device is powered from the AC power source only The DC source starts feeding the device only upon an AC power outage Table 5 5 DC Power Specifications Physical Specification Value Input Voltage 12VDC 10A Use only the AC DC power adaptor that is provided by AudioCodes when ordering DC power To connec...

Страница 35: ... SBC Hardware Installation Manual Table 5 6 Connecting DC Power Plug to DC Inlet 2 Plug the female connector that is located on one end of the AC power cord supplied into the AC DC power adaptor Figure 5 20 Plugging AC Power Cord into AC DC Adaptor 30 ...

Страница 36: ... Device Mediant 800 Gateway E SBC Hardware Installation Manual 3 Plug the other end of the AC power cord supplied into a standard electrical wall outlet The device s DC PWR LED located on the front panel lights up green 31 ...

Страница 37: ...acturer Manufacturer Part Number LITTEFUSE 215 06 3 6 3A 250V For continuous protection replace only with the same fuse type and rating fuse The power fuse is applicable only to AC power To replace the fuse 1 Unplug the power cord from the electrical outlet 2 Using a small flathead screwdriver gently pries open the fuse cavity as illustrated in the following figure Table 6 2 Opening the Fuse Cavit...

Страница 38: ...This page is intentionally left blank CHAPTER 6 Maintenance Mediant 800 Gateway E SBC Hardware Installation Manual 33 ...

Страница 39: ...oCodes Ltd All rights reserved AudioCodes AC HD VoIP HD VoIP Sounds Better IPmedia Mediant MediaPack What s Inside Matters OSN SmartTAP User Management Pack VMAS VoIPerfect VoIPerfectHD Your Gateway To VoIP 3GX VocaNom AudioCodes One Voice AudioCodes Meeting Insights AudioCodes Room Experience and CloudBond are trade marks or registered trademarks of AudioCodes Limited All other products or tradem...