CHAPTER 5 Cabling the Device
Mediant 500 Gateway & E-SBC | Hardware Installation Manual
Pin
Signal Name
4
Ethernet signal pair (1000Base-T)
5
7
Ethernet signal pair (1000Base-T)
8
Shield
Chassis ground
➢
To connect the device to the LAN:
1.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45 port labeled
S1
/ LAN GE
.
Figure 5-2:
Cabling the LAN Ports
2.
Connect the other end of the cable to the Gigabit Ethernet network.
Connecting to an ISDN PRI (E1/T1) Trunk
The procedure below describes the cabling of the device's E1/T1 (PRI) trunk interface.
To protect against electrical shock and fire, use a 26 AWG min wire to connect the E1 /
T1 port to the PSTN.
PRI interface is a separate orderable item.
The RJ-48c trunk connector used in the cabling is wired according to the following figure:
Figure 5-3:
RJ-48c Connector Pinouts for E1/T1
➢
To connect the E1/T1 trunk interface:
1.
Connect the E1/T1 trunk cable to the device’s E1/T1 port.
2.
Connect the other end of the trunk cable to your PBX/PSTN switch.
- 15 -