Connecting Remotely to OSN3 using Windows
You can connect to the OSN3 server using Microsoft's Remote Desktop Connection
program.
Notes:
•
To connect remotely to the OSN3 server running Windows, make sure that Remote
Desktop is enabled.
•
The remote PC must be in the same subnet as the OSN server (default IP address
is 10.1.10.12).
•
If, for any reason, you use an HDMX module taken from another chassis with OSN3
running Windows 2008, the default static IP address (10.1.10.12) is no longer
applicable. This is because the module becomes a DHCP client and acquires a
different IP address. To configure a specific IP address, you need to use a serial
console, as described in the following section.
A.4.1 Modifying the OSN3 IP Address
If, for any reason, you use an HDMX module taken from another chassis with OSN3
running Windows 2008, the default static IP address (10.1.10.12) is no longer applicable.
This is because the module becomes a DHCP client and acquires a different IP address. To
configure a specific IP address, you need to use a serial console, as described below.
To manually configure an IP address (for the scenario described in the note
above):
1.
Connect the OSN3 serial interface port to a PC console using the RJ-45-to-DB-9 cable
adapter (see Section
on page
2.
Use a serial communication software (e.g., HyperTerminal) to establish a serial
communication link, using the following communication port settings:
•
Baud Rate: 115,200 bps
•
Data Bits: 8
•
Parity: None
•
Stop Bits: 1
•
Flow Control: None
3.
Wait until the following Windows 2008 message is displayed:
EVENT: The CMD command is now available.
4.
To view the current IP address, at the SAC prompt, type i, and then press Enter:
SAC>i
Net: 55, Ip=169.254.225.21 Subnet=255.255.0.0
Gateway=0.0.0.0
Net: 55, Ip=fe80::8154:57cb:6b0e:e115
Note:
For Kontron OSN3, three Nets are displayed - two are disconnected and one is
the same as above.
5.
Identify the network interface ID (NIC). For example, in the above, the Net ID is 55.
Содержание Mediant 1000B
Страница 1: ...Hardware Installation Manual Mediant 1000B MSBR Multi Service Business Router SIP Protocol ...
Страница 2: ......
Страница 12: ...Hardware Installation Manual 12 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Страница 14: ...Hardware Installation Manual 14 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Страница 34: ...Hardware Installation Manual 34 Document LTRT 40881 Mediant 1000B MSBR Reader s Notes ...
Страница 70: ...Hardware Installation Manual www audiocodes com ...