Preface

Please  take  time  to  carefully  read  and  understand  the 
following instructions before you install or attempt to oper-
ate  this  equipment.  Becoming  familiar  with  the  product 
and its correct operating procedures will help assure you of
maximum  musical  enjoyment  and  reliable  operation.  The
effort  you  invest  now  will  be  well  rewarded  in  the  years
ahead

Packaging

Save  all  packaging  accompanying  this  product.  You  have
purchased a precision electronic instrument, and it should
be  properly  cartoned  any  time  shipment  becomes  neces-
sary.  It  is  very  possible  that  this  unit  could  be  damaged
during shipment if repackaged in cartoning other than that
designed for it. The original packaging materials help pro-
tect your investment from unnecessary damage, delay and
added expense whenever shipment of this unit is required.

Accessories

1 – Phillips head screwdriver for cover removal
1 – Plastic screwdriver for bias adjustments

User replaceable spare fuses include:

1 – 7 Amp MDQ slo-blo with 120V units or 100V units
1 – T4A 250V slo-blo with 220V/240V units

Warnings

1

. Do not touch hot tubes. Keep away from children.

2

. To prevent fire or shock hazard, do not expose your 

Reference 110 to rain or moisture.

3

.

This  unit  contains  voltages  which  can  cause  serious 
injury  or  death.  Do  not  operate  with  covers  removed. 
Refer servicing to your authorized Audio Research dealer
or other qualified personnel.

4

. The  12-gauge,  3-conductor  detachable  power  cord  on

your Reference 110 is equipped with a standard 3-prong
grounding  plug.  If  used  normally,  it  will  provide  a  safe
earth  ground  connection  of  the  chassis.  Refer  to  the 
section  on  “AC  Power  Connections”  for  detailed 
information.

5

. For  continued  protection  against  fire  hazard, 

replace fuses only with the same type and rating of fuses
as specified.

Warning!

Read Owner's Manual before installing or operating
this product!

Do  not  attempt  to  install  or  remove  any  vacuum
tubes unless this unit is turned off and disconnected
from the A.C. power outlet. Unit should be connect-
ed  to  the  A.C.  outlet  and  turned  on  only  after  all 
vacuum  tubes  have  been  installed  and  appropriate
pa nels  have  be en  repla ced  and  faste ne d.  Se e 
owner's manual for installation instructions.

Before replacing vacuum tubes, turn off unit, discon-
nect  from  A.C.  outlet  and  allow  installed  tubes  to
cool  before  attempting  to  remove  them.  Hot  tubes
may  cause  burns  or  other  injury  if  not  allowed  to
cool before removal.

When removing or installing tubes, do not touch tube
socket contacts or other components as the circuit
may retain sufficient levels of voltage and current to
cause injury or death.

Contact  your  dealer  or  Audio  Research  Customer
Service  (763-577-9700)  if  you  have  any  questions
about  installing  or  replacing  vacuum  tubes  in  this
unit.

Model Reference 110

DO NOT ATTEMPT TO OPERATE THIS

EQUIPMENT BEFORE INSTALLING THE NUMBERED

VACUUM TUBES IN THEIR RESPECTIVE SOCKETS.

R E A R

F R O N T

V 7

V 5

V 9

V 3

V 2

V 1

V 4

V 12

V 6

V 10

V 8

V 11

(8) 

6550C

(4) 

6H30

TUBE LOCATIONS

TOP VIE W

1

Содержание Reference 110

Страница 1: ...3900 ANNAPOLIS LANE NORTH PLYMOUTH MINNESOTA 55447 5447 PHONE 763 577 9700 FAX 763 577 0323 Model Reference 110 STEREO POWER AMPLIFIER Owner s Manual...

Страница 2: ...Preparation for Use 2 Panel Controls 2 Use of Controls 2 Installation 2 Connections 2 3 Remote Turn on Connections 3 Operating Procedure 3 Output Tube Bias Adjustment 4 Cooling Fan Speed Adjustment 4...

Страница 3: ...S WHICH MAY BE HAZARDOUS REFERENCE 110 S T E R E O A M P L I F I E R VOLTS SERIAL PLYMOUTH MINNESOTA CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD REPLACE FUSE ONLY WITH SAME TYPE AND RATING WA...

Страница 4: ...The 12 gauge 3 conductor detachable power cord on your Reference 110 is equipped with a standard 3 prong grounding plug If used normally it will provide a safe earth ground connection of the chassis R...

Страница 5: ...r installation will cause premature tube failure and will affect your warranty as well as the service life of the unit It is normal for a vacuum tube power amplifier to run quite warm and if used for...

Страница 6: ...in the preamplifier through its grounded power cord Other equipment in the system should have some form of isola tion to prevent ground loops and associated hum Always place the power on off switch on...

Страница 7: ...ld stop running Hour Meter An LCD hour meter of elapsed tube operating time can be viewed through the top cover near the front mounted on the right main circuit board Displays accumulated hours of vac...

Страница 8: ...encountered and any information necessary for return shipment The cost of return shipment is the responsibility of the purchaser Specifications POWER OUTPUT 110 watts per channel continuous from 20Hz...

Отзывы: