Model Reference 110

P O W E R

VACUUM TUBE

POWER AMPLIFIER

REFERENCE 110

HIGH DEFINITION

®

WARNING

TO PREVENT FIRE AND SHOCK HAZARD, DO NOT 

EXPOSE THIS DEVICE TO RAIN OR MOISTURE.

UNIT MUST BE OPERATED IN A HORIZONTAL POSITION.

- DO NOT OPERATE WITH COVERS REMOVED -

UNIT CONTAINS VOLTAGES WHICH MAY BE HAZARDOUS

REFERENCE 110

S T E R E O   A M P L I F I E R  

VOLTS

S E R I A L

PLYMOUTH, MINNESOTA

C A U T I O N

FOR CONTINUED PROTECTION AGAINST 

FIRE HAZARD REPLACE FUSE ONLY 

WITH SAME TYPE AND RATING 

W A R N I N G !

RISK OF HAZARDOUS ENERGY!

MAKE PROPER SPEAKER CONNECTIONS

SEE OWNERS MANUAL

W A R N I N G !

RISK OF HAZARDOUS ENERGY!

MAKE PROPER SPEAKER CONNECTIONS

SEE OWNERS MANUAL

7A FUSE

SLO-BLO

T4A (230V)

800 W MAX

50 / 60 HZ

~

LEFT

INPUT

RIGHT
INPUT

4

Ω

8

Ω

0

Ω

16

Ω

4

Ω

8

Ω

0

Ω

16

Ω

IN

+12V

REMOTE TURN ON

OUT

Содержание Reference 110

Страница 1: ...3900 ANNAPOLIS LANE NORTH PLYMOUTH MINNESOTA 55447 5447 PHONE 763 577 9700 FAX 763 577 0323 Model Reference 110 STEREO POWER AMPLIFIER Owner s Manual...

Страница 2: ...Preparation for Use 2 Panel Controls 2 Use of Controls 2 Installation 2 Connections 2 3 Remote Turn on Connections 3 Operating Procedure 3 Output Tube Bias Adjustment 4 Cooling Fan Speed Adjustment 4...

Страница 3: ...S WHICH MAY BE HAZARDOUS REFERENCE 110 S T E R E O A M P L I F I E R VOLTS SERIAL PLYMOUTH MINNESOTA CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD REPLACE FUSE ONLY WITH SAME TYPE AND RATING WA...

Страница 4: ...The 12 gauge 3 conductor detachable power cord on your Reference 110 is equipped with a standard 3 prong grounding plug If used normally it will provide a safe earth ground connection of the chassis R...

Страница 5: ...r installation will cause premature tube failure and will affect your warranty as well as the service life of the unit It is normal for a vacuum tube power amplifier to run quite warm and if used for...

Страница 6: ...in the preamplifier through its grounded power cord Other equipment in the system should have some form of isola tion to prevent ground loops and associated hum Always place the power on off switch on...

Страница 7: ...ld stop running Hour Meter An LCD hour meter of elapsed tube operating time can be viewed through the top cover near the front mounted on the right main circuit board Displays accumulated hours of vac...

Страница 8: ...encountered and any information necessary for return shipment The cost of return shipment is the responsibility of the purchaser Specifications POWER OUTPUT 110 watts per channel continuous from 20Hz...