background image

Connections

INPUT  CONNECTORS:

There  is  one  set  of  RCA  input 

connectors,  which  should  be  connected  to  your
turntable/tonearm cable. 

OUTPUT  CONNECTORS:

T h e re  is  one  set  of  RCA 

output  connectors  which  should  be  connected  to  line  in-
puts (Direct, Aux, Spare, Tuner, etc.) of your line stage/pre-
amplifier.  Single  ended  RCA-to-balanced  adapters  are 
available  from  Audio  Research  allowing  the  PH5  to  be 
connected  directly  to  a  balanced  input  preamplifier  using
single ended RCA interconnects.

All  input/output  connectors  are  gold  plated  and  connect
“ground” before “hot”. On disconnect, “hot” is disconnected
first.

NOTE:

A "passive" line stage is not recommended for use

with  the  PH5  as  it  will  not  provide  the  gain  necessary  to
amplify  the  output  of  the  PH5  to  adequate  levels  to  the
power amplifier.

At  the  performance  level  of  the  PH5,  high  quality 
audio signal interconnect cables such as the Audio Research
Litzlink  2  are  critical  to  preserving  maximum  fidelity.
Please consult your Audio Research dealer.

Installation Instructions

While  the  PH5  does  not  dissipate  an  unusual  amount  of
heat,  it  is  important  that  it  have  a  reasonable  airflow  to 
assure long, trouble-free operation. In addition, the follow-
ing installation guidelines will help insure maximum sonic
performance as well as reliable service.

1.

Upright  and  horizontal  mounting  is  required 
if extended operation (longer than one hour) is contem-
plated.

2.

Do not “stack” the PH5 on top of other equipment: not
only  could  this  cause  overheating,  but  “hum”  may  be 
introduced  into  the  phono  circuits  from  the  proximity 
of the power transformer of the other equipment.

3.

Do not place or operate unit on a soft or irregular surface
such as a rug. This will prevent proper ventilation.

4.

Do not operate unit without the top and bottom covers
installed.  These  are  required  both  for  safety  as  well 
as  shielding  from  interference  (except  in  service  opera-
tions).

5.

If  side-by-side  mounting  with  other  equipment  is 
employed, place the PH5 to the left of the other chassis,
so  as  to  provide  maximum  spacing  between  the  trans-
former of the PH5 and the other component.

6.

In  a  cabinet  or  rack-mount  installation  which  has  an 
enclosed  back,  an  exhaust  fan  is  desirable  so  as  not  to
operate the PH5 in overheated ambient air. Operation of
vacuum tube equipment for long periods of time in hot
ambient air will shorten tube life and increase chance of
failure of other component parts.

Operating/Start-up Procedure

1.

Secure  connections  between  turntable,  PH5,  and  line
stage  preamplifier. 

N o t e :

Given  the  advanced  perfor-

mance capabilities of the PH5, it is extremely important
that high-quality interconnects be used for connection to
ancillary  electronics.  Audio  Research  brand  intercon-
nects,  in  either  unshielded  or  RFI-shielded  configura-
tions, are strongly recommended. Your authorized Audio
Research dealer can assist you in determining which type
and lengths are optimal for your system.

2.

Plug  3-prong  power  cord  into  a  grounded  AC  wall 
receptacle.

3.

Turn  Power  switch  “on.”  The  green  “Power”  LED  will
light  and  the  mute  LED  will  flash  for  approximately 
30 seconds while the power supply stabilizes, indicating 
operation  of  the  automatic  muting  circuit.  After t h i s
warm-up  period  the  mute  LED  will  stay  on  and  the 
cartridge  loading  value  LED  will  light,  indicating  that
your PH5 is ready for operation. 

4.

Unmute PH5, select proper cartridge loading and play.

Not e :

For  superior  sonic  performance,  a  warm-up 

period of at least one hour is recommended. 

Servicing

Because  of  its  careful  design  and  exacting  standards 
of  manufacture,  your  PH5  should  normally  require  only
minimal  routine  service  to  maintain  its  high  level  of 
performance.

C A U T I O N :

Your  PH5  contains  sufficient  levels  of  voltage

and current to be lethal. Do not tamper with a component
or  part  inside  the  unit.  Refer  any  needed  service  to  your 
authorized  Audio  Research  dealer  or  other  qualified 
technician.

The  vacuum  tubes  inside  your  PH5  are  6922  dual 
triodes,  and  with  normal  use  should  not  need  to  be
changed for approximately 2,000 hours of use.

Model PH5

2

Содержание PH5

Страница 1: ...3900 ANNAPOLIS LANE NORTH PLYMOUTH MINNESOTA 55447 5447 PHONE 763 577 9700 FAX 763 577 0323 Model PH5 PHONO PREAMPLIFIER Owner s Manual ...

Страница 2: ...Preface 1 Warnings 1 Packaging 1 Front Panel Controls 1 Connections 2 Installation Instructions 2 Operating Start up Procedure 2 Servicing 2 Cleaning 3 Disposal and Recycling Guidelines 3 Warranty Terms and Conditions 3 Specifications 4 ...

Страница 3: ... T1A 230V MODEL PH5 V A C U U M T U BE P H O NO P RE A M P L I F I E R PLYMOUTH MINNESOTA MADE IN U S A WARNING TO PREVENT FIRE AND SHOCK HAZARD DO NOT EXPOSE THIS DEVICE TO RAIN OR MOISTURE UNIT MUST BE OPERATED IN A HORIZONTAL POSITION DO NOT OPERATE WITH COVERS REMOVED UNIT CONTAINS VOLTAGES WHICH MAY BE HAZARDOUS CAUTION FOR PROTECTION AGAINST FIRE HAZARD REPLACE ONLY WITH SAME RATING FUSES SE...

Страница 4: ...sion requiring shipment occurs the original packaging will protect your PH5 from unnecessary damage or delay Note that your PH5 has been shipped with the vacuum tubes installed in a protective foam block under the top cover With the PH5 unplugged use a phillips head screw driver to loosen the fastening screws remove the top cover and set aside Install the numbered tubes in their respective sockets...

Страница 5: ...th other equipment is employed place the PH5 to the left of the other chassis so as to provide maximum spacing between the trans former of the PH5 and the other component 6 In a cabinet or rack mount installation which has an enclosed back an exhaust fan is desirable so as not to operate the PH5 in overheated ambient air Operation of vacuum tube equipment for long periods of time in hot ambient ai...

Страница 6: ... vacuum tubes This Limited Warranty initiates from the date of purchase and is limited to the original purchaser or in the case of demonstration equipment limited to the balance of warranty remaining after original shipment to the retailer or importer In the United States the specific terms conditions and remedies for fulfillment of this Limited Warranty are listed on the warranty card accompanyin...

Страница 7: ...50V RMS 10Hz to 60kHz 100K ohm load output capability is 50V RMS output at 1 2 THD at 1kHz POWER SUPPLIES Electronically regulated low and high voltage supplies Line regulation better than 01 NOISE 0 16uV equivalent input noise IHF weighted shorted input 76 dB below 1mV 1kHz input TUBE COMPLEMENT 4 6922 E88CC dual triodes with JFET input Solid state power supply POWER REQUIREMENTS 100 135VAC 60Hz ...

Отзывы: