background image

13

Operation

Remote Only Functions

In addition to the controls found on 

the front panel, the remote control 

offers access to the following 

additional features of the LS28.

Hours

Pressing the ‘HOURS’ button will display 

the total accumulated hours of operation 

for the LS28. This is useful to determine 

the approximate number of hours the 

vacuum tubes have been in use. After 

five seconds, the display will revert to 

the normal operation screen. After 

replacing vacuum tubes, the hours 

counter should be reset (see instructions 

under ‘Settings Menu’ on page 16).

Note

The installed 6H30 vacuum tubes have an 

average life span of approximately 4,000 

hours. After this time, we recommend 

replacing them to maintain the best 

performance of your preamplifier.

Input Select Buttons

The input buttons labeled BAL 1-4 and 

SE 1-4 allow direct selection of each of 

the eight inputs available on the LS28.

Display Brightness Adjustment

The front panel display has six brightness 

settings, as well as the ability to dim 

the display completely. To change the 

brightness, use the ‘DSP UP’ or ‘DSP DN’ 

buttons on the remote. Note that when 

the display is completely dimmed, a 

small square appears in the middle of the 

display to indicate the unit is powered on. 

Balance

The Balance control adjusts the output from 

center position to the left or right channels, 

which in turn will shift the center point of 

the sonic image. This is useful in the event 

the main listening position is not centered 

between the speakers, or can help with 

certain room anomalies.

To adjust the balance, press the ‘BAL L’ or 

‘BAL R’ button on the remote. The balance 

scale will appear in the middle of the 

display, and the indicator will move in the 

selected direction:

After five seconds of inactivity, the 

balance scale will disappear from the 

screen. If the balance has been shifted 

to the right or left, ‘R+’ or ‘L+’ will 

appear at the bottom left corner.

Содержание LS28

Страница 1: ...LS28...

Страница 2: ......

Страница 3: ...gin listening however please take a few minutes to read through this guide for useful information concerning the operation of your new preamplifier Once installed please allow an appropriate break in...

Страница 4: ...er 5 6 7 7 8 9 9 9 9 9 Operation Front Panel Controls and Display Start Up Shut Down Break in Front Panel Controls Remote Only Functions Settings Menu System Settings Menu Tree Settings Menu Auto Shut...

Страница 5: ...ontinued protection against fire hazard replace the fuse only with the same type and rating as specified at the fuse holder see page 19 for fuse information This unit is RoHS compliant The LS28 has au...

Страница 6: ...ns Installation Remove all screws fastening the top cover Carefully remove each vacuum tube from its protective foam and match its location V number written on the base of the tube to the V number pri...

Страница 7: ...enclosure such as an equipment rack make certain that adequate airflow above and to each side of the unit is provided Audio Research recommends a minimum of 6 8 inches 15 20 cm of clearance above the...

Страница 8: ...8 Connections Back Panel Connections Record Outputs Main Outputs RS 232 connector Control connections Fuse Holder A C Mains connector Single ended Inputs Balanced Inputs...

Страница 9: ...amplifier s and could cause serious serious damage to the amplifier s or loudspeakers A C Power Connection It is important that the LS28 be connected via its supplied 15 amp IEC 14 gauge power cord to...

Страница 10: ...10 Operation Front Panel Controls and Display Input Select Vacuum Fluorescent Display Volume Power On Off Menu Enter used with Menu Mono Stereo Invert Phase Mute...

Страница 11: ...OFF will flash on the display until the warm up cycle is complete Select input source and adjust the volume as necessary Shut Down Activate MUTE function Turn off power amplifier s Press Power switch...

Страница 12: ...preamp indicated by active display window The LS28 requires approximately 45 seconds to warm up this time is required to stabilize the vacuum tubes See Start Up Procedure on page 11 for details Menu...

Страница 13: ...f the eight inputs available on the LS28 Display Brightness Adjustment The front panel display has six brightness settings as well as the ability to dim the display completely To change the brightness...

Страница 14: ...14 Operation System Settings Menu Tree...

Страница 15: ...the front panel display Both the MENU and ENTER buttons found on the front panel and remote as well as the volume knob or the up down volume buttons on the remote are used to make changes to the menu...

Страница 16: ...the bottom line When using the input selected for processor mode note that in place of the volume number on the operation screen a pass through symbol will be shown Warning When processor mode is ass...

Страница 17: ...eset them to zero after a power off cycle When volume reset is set to OFF the LS28 will also remember settings after a power cycle To change the status of the volume reset press the MENU button until...

Страница 18: ...t Even with the power turned off a charge remains in the energy storage capacitors for hours or even days Cleaning To maintain the new appearance of this preamplifier occasionally wipe the front panel...

Страница 19: ...19...

Страница 20: ...the United States the authorized importing retailer or distributor has accepted the responsibility for warranty of Audio Research products sold by them The specific terms and remedies for fulfillment...

Страница 21: ...16V RMS BAL 8V RMS SE Rated Outputs 2V RMS 1V RMS SE into 200K ohm balanced load maximum balanced output capability is 17V RMS at less than 0 5 THD at 1kHz Crosstalk 105dB or better at 1kHz Controls R...

Страница 22: ...notice 2016 Audio Research Corporation Reproduction of this document in part or whole is expressly forbidden without written consent from Audio Research Corporation 3900 Annapolis Lane North Plymouth...

Отзывы: