23 - Priority
When these terminals are short circuit (e.g. using an electrical switch), the audio signal of CH 2 to CH 5 are
attenuated.
24 - Monitor 1W 8 Ω
This terminal can be used for monitoring, using a simple 8 Ω passive speaker. The output delivers 1 W. This
output is controlled by the MONITOR VOLUME (11) knob on the front panel.
25 - Monitor Line Out
Output also controlled by the MONITOR VOLUME (11) knob on the front panel and to be connected to
external amplification system.
26 - Zone Line Out
Zone balanced output to be used with external amplifier devices if necessary.
27 - Power Amp. Output 25 / 70 / 100 V
Powered zone outputs requiring speakers equipped with 25 V / 70 V or 100 V line transformers and a parallel
connection.
Caution, the sum of the powers of the speakers must not exceed the nominal power of the output
amplifier
. For example, it will not be possible to use more than 12 speakers 10 W on the same zone.
When manipulate the speaker connectors, make sure that the power is turned off, then replace the plastic cap
on the barrier strip in order to avoid any electric shock.
28 - Power Amp. Output 4 Ω / 8 Ω
These terminal can be used with conventional low impedance speaker if long distance connections are not
necessary. Be aware not using loads less than 4 Ω at risk of damaging the amplifier.