background image

Audio International, Inc.

 

 

                         VCP-015-02-x Installation & Operation Manual 

 
 

 
Document # 540228, Rev A, 05/2003  

                         

Page 10 of 18 

5.5 

When running cables, avoid sharp bends and placing cables near aircraft 
control cables.  Maintain a MINIMUM clearance of three (3) inches from 
any control cable.  If wiring is run parallel to combustible fluid or oxygen 
lines, maintain a separation of six (6) inches between the lines.   

 

5.6 

Bonding between chassis mounting point and airframe installation to be  
<1 

 resistance using <50 

 impedance cable.  No surface prep is 

required due to conductive chassis finish (except front bezel). 

 

 
6.0   Electrical Characteristics 

 

6.1 Electrical 

Specifications: 

 
 

Electrical 

Power 

1A @ +28 VDC 

 

Operating Voltage 

Range 

+18 to +32 VDC 

 

Data Bus Type 

AI Proprietary RS-485 

 

Audio Frequency 

Response 

200 Hz to 8 kHz 

 

Audio S/N 

>37dB (NOMINAL) 

 

Video Output 

1 V

(p-p) 

into 75 

 

 

Playback Format 

PAL, MESECAM, & NTSC 

 

Video Output 

NTSC 

 

Video Heads 

 

Infrared Signal Input 

+5 VDC digital logic level 

 
 

6.2 

  The VCP-015-02-x utilizes one (1) 15-pin connector for electrical 

connections.  This connector provides power, left/right audio output, data 
bus control, infrared input, and eight (8) infrared strapping pins for 
alternate configuration of infrared digital command codes to allow up to 
eight (8) VCP-015-02-x in the same system. 
 

6.3    Mating Connector Information 

 
 

Model # 

Mating Connector 

VCP-015-02-1 RD15F10JVL0 

VCP-015-02-2 

DAMA-15S 

D20418-2 Female Screwlock 

BNC1 Video Output  AMPHENOL 31-71013 or equivalent 

 
 

Содержание VCP-015-02-x

Страница 1: ...Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 www audiointl com Installation and Operation Manual VCP 015 02 x Multi Standard Video Cassette Player Document 540228 a DeCrane Air...

Страница 2: ...Service Bulletin Subject Manual Revision Revision Date Table of Illustrations Section Description Page I Subsection 6 2 Typical Application 5 II Subsection 3 9 Acceptable Mounting Positions 7 II Subse...

Страница 3: ...Specifications 4 6 0 Application 4 II INSTALLATION 6 1 0 Prior to Installation 6 2 0 Unpacking and Inspection 6 3 0 Cautions Warnings 7 4 0 Wiring Requirements 8 5 0 Physical Characteristics 9 6 0 El...

Страница 4: ...d the VCP 015 02 x as a high quality video cassette player that meets all the special requirements of aircraft use This unit supports all standard Video Cassette Playback features including Play Stop...

Страница 5: ...ctly complement the VCP 015 02 x and serve as valuable and attractive additions to any cabin interior Contact your AI representative for details 5 0 Technical Specifications Physical Specifications Ho...

Страница 6: ...ilizing AI s remote control unit AI RCx 17xxxx and IFR 9A This following configuration utilizes a 5 VDC digital logic level for activation of infrared commands Connection to multiple IFR 9A units util...

Страница 7: ...he standards designated by the customer installing agency and existing conditions as to the unit location and type of installation 1 3 Mounting screws are required to secure the unit The unit shall be...

Страница 8: ...wer and ground are applied only where specified Damage to the unit may result if power or ground is applied to the wrong points 3 2 DO NOT connect or disconnect the unit while power is applied 3 3 DO...

Страница 9: ...roduction The installing agency shall supply and fabricate all external cables The length and routing of external cables should be carefully studied and planned before attempting installation of the e...

Страница 10: ...A WC 27500 or equivalent The wire size for the conductors in this cable shall be 22 AWG MINIMUM The shield shall be connected everywhere a shield pin is provided Shield terminations shall be made as c...

Страница 11: ...ical Specifications Electrical Power 1A 28 VDC Operating Voltage Range 18 to 32 VDC Data Bus Type AI Proprietary RS 485 Audio Frequency Response 200 Hz to 8 kHz Audio S N 37dB NOMINAL Video Output 1 V...

Страница 12: ...ected to the unit The audio signal output of the unit is generally connected to cabin speaker systems in addition to headphone locations Verify all connections before supplying power to the unit Verif...

Страница 13: ...ll connections to the unit for security and all harness runs for possible pinching Recheck all pinouts for application accuracy Utilizing a voltmeter oscilloscope or other voltage instrument verify pr...

Страница 14: ...not present Cassette not installed Tape defective Video connector not operational Install videocassette Replace videocassette tape Reconnect or repair cable Audio not present Defective videocassette...

Страница 15: ...VCP 015 02 x Installation Operation Manual Document 540228 Rev A 05 2003 Page 14 of 18 9 0 Reference Drawings The following diagrams show the unit dimensions mounting locations and connector location...

Страница 16: ...Audio International Inc VCP 015 02 x Installation Operation Manual Document 540228 Rev A 05 2003 Page 15 of 18...

Страница 17: ...y controlled by infrared remote or AI s touch screen panel Digital codes allow the unit to interface with an infrared handheld remote via an infrared receiver IFR 9A or IFR 485 Multiple units can be c...

Страница 18: ...tte is inserted incorrectly the loading system will not function Do not force the tape into the unit 3 0 Front Panel Button Functions Button Press the STOP button to stop videocassette tape playback B...

Страница 19: ...me 4 4 To pause the screen during playback press PAUSE Playback will stop and the current screen will enter a still frame mode Pressing PAUSE again will advance the movie one 1 frame forward To return...

Отзывы: