Audio international RCD-020-x Скачать руководство пользователя страница 8

AUDIO INTERNATIONAL, INC. 

 

2/98 

 

Document #540067, Rev. IR, Model No.: RCD-02x-x & RCD-020x-40x 

2.4  

Wiring Requirements 

 

2.4.1  The installing agency must supply and fabricate all external cables.  The 

length and routing of external cables must be carefully studied and 
planned before attempting installation of the equipment.  Allow adequate 
space for installation of cable and connectors.  Avoid sharp bends and 
placing cables near aircraft control cables.  Maintain a minimum clearance 
of three (3) inches from any control cable.  If wiring is run parallel to 
combustible fluid or oxygen lines, maintain a separation of six (6) inches 
between the lines.   

 

2.4.2  All power and ground wires must be 24 AWG minimum. All audio lines 

require twisted, shielded cable with the cable shields grounded.  Power 
ground wires must be grounded within twelve (12) inches of the unit.  All 
wires must be in accordance with MIL-W-22759 or equivalent.  Twisted, 
shielded cable must be in accordance with MIL-W-27500 or equivalent.  
Protect power wires with circuit breakers or fuses located close to the 
electrical power source bus. 

 
2.4.3  The RCD-020-40x and RCD-021-40x are designed to interface with other 

AI equipment via the proprietary RS-485 data bus.  This is a bi-directional 
data bus that allows multiple units to be connected simultaneously.  The 
lines are daisy-chained between units with 120-ohm resistors installed at 
both ends of the wiring harness.  Cable designed specifically for data bus 
use with 120-ohm nominal impedance should be utilized.  Contact Audio 
International for recommended cables. 

 

2.5 Physical 

Requirements 

 

2.5.1  Refer to Section 5.1 for unit dimensions and mounting attachment points. 
 

2.6 Electrical 

Requirements 

 

2.6.1  The RCD-020-1 and RCD-020-401 each utilize one 21-pin positronic 

connector for electrical connections.  This connector provides 28 VDC, 
left/right audio output, infrared input, antenna high, antenna shield, 12 
VDC battery holdup, and four (4) strapping pins for alternate 
configuration of infrared digital command codes.  It also provides data bus 
control for the RCD-020-401.   

 
2.6.2  The RCD-020-2 and RCD-020-402 each utilize one 21-pin D-

subminiature connector for electrical connections.  This connector 
provides 28 VDC, left/right audio output, infrared input, antenna high, 
antenna shield, 12 VDC battery holdup, and four (4) strapping pins for 
alternate configuration of infrared digital command codes.  It also 
provides data bus control for the RCD-020-402.  Refer to Section 2.8 for 
connector/unit connector information. 

Содержание RCD-020-x

Страница 1: ...r L 7300 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 Product Installation Manual Compact Disc Player AM FM Tuner Model No s RCD 020 x 40x RCD 021 40x Document 540067...

Страница 2: ...x x RCD 020x 40x Revision History Rev Level Date Description IR 2 98 Initial Release Applicable Documents Document Drawing Description Rev N A 521130 RCD 020 x 40x CD Player AM FM Tuner A2 N A 521871...

Страница 3: ...RNATIONAL INC 2 98 3 Document 540067 Rev IR Model No RCD 02x x RCD 020x 40x Service Bulletin List Service Bulletin Subject Manual Revision Manual Revision Date List of Illustrations Section No Descrip...

Страница 4: ...nections 8 2 7 Pinouts Descriptions 9 2 8 Connector Mating Connector Information 10 2 9 Post Installation Test 10 3 0 Operation 10 3 1 Audio Input 10 3 2 Potentiometer Adjustment 10 3 3 Audio Adjustme...

Страница 5: ...of aircraft use These units allow complete control of track selection Features include track search track repeat track scan and random play mode The units have high quality output adjustable stereo o...

Страница 6: ...wisted shielded pair 24 AWG minimum unless otherwise specified The unit must be attached to conform to the standards designated by the customer installing agency and existing conditions as to the unit...

Страница 7: ...orage or reshipment if necessary 2 3 Cautions Warnings 2 3 1 All audio connections to the RCD should be shielded and properly grounded at the source Perform a pin to pin check to confirm that all wire...

Страница 8: ...h other AI equipment via the proprietary RS 485 data bus This is a bi directional data bus that allows multiple units to be connected simultaneously The lines are daisy chained between units with 120...

Страница 9: ...strap common Three 3 strap pins are available to allow the infrared codes to be configured 2 7 Pinouts Descriptions 2 7 1 The RCD 020 x 40x unit connector with its respective pins and descriptions is...

Страница 10: ...the unit 2 9 2 Utilize the front panel controls to turn ON the AM FM tuner Utilize the AM FM random search button to select a desired radio station Verify that the station can be heard through the spe...

Страница 11: ...nd audio output is present Insert audio material in source unit Poor audio quality Audio controls are not adjusted properly Adjust output level Poor Tuner reception Antenna connection may be faulty Ve...

Страница 12: ...ble Sensitivity S N 30dB 9 3 dBf 0 8 V 75 ohms Frequency Response 30 Hz to 15 kHz 3 dB Signal to Noise Ratio 75 dB MONO Stereo Separation 40 dB 1 kHz AM Tuner Specifications Frequency Range 530 kHz 17...

Страница 13: ...el No RCD 02x x RCD 020x 40x 5 2 2 The following diagram shows the top view of the RCD with unit dimensions 5 2 3 The following is a reduced diagram showing the side and rear views of the RCD 020 x 40...

Страница 14: ...AL INC 2 98 14 Document 540067 Rev IR Model No RCD 02x x RCD 020x 40x 5 2 4 The following is a reduced diagram showing the side and rear views of the RCD 021 40x unit showing the ball stud location an...