![Audio international DVD-021-0x-1 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/audio-international/dvd-021-0x-1/dvd-021-0x-1_installation-and-operation-manual_3008286010.webp)
Audio International, Inc.
DVD-021-0x-x Installation & Operation Manual
Document # 540125, Rev B, 12/2000
Page 9 of 31
3.11 DO NOT expose to sun or bright light. Damage to the sensor will result.
3.12 ESD (Electro Static Discharge) guidelines shall be followed.
4.0 Wiring
Requirements
4.1
Introduction
The installing agency shall supply and fabricate all external cables. The
length and routing of external cables should be carefully studied and
planned before attempting installation of the equipment. Allow adequate
space for installation of cable and connectors. Avoid sharp bends and
placing cables near aircraft control cables. Maintain a minimum clearance
of three (3) inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6) inches
between the lines.
4.2 Power Wires
All power and ground wires shall be 22 AWG, MINIMUM. Power ground
wires shall be grounded within 12 inches of the unit. All wires shall be in
accordance with the standard military specification of MIL-W-22759 or
equivalent. Twisted, shielded cable shall be in accordance with the
standard military specification of MIL-DTL-27500 or equivalent. Protect
power wires with circuit breakers or fuses located close to the electrical
power source bus.
4.3
Video Lines
All video line connections require shielded coaxial cable with the shield
properly grounded at the source. RG-179 cable or equivalent is
recommended.