AI-VC-101, -102 Installation Manual
Document # 540116, Rev. B, 09/2001
Page 5 of 9
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Ensure that power and ground are applied only where
specified. Damage to the unit may result if power or ground is
applied to the wrong points.
3.3.2 DO NOT connect or disconnect the module while power is applied.
3.3.3 DO NOT remove any factory-installed screws. Damage to the units
may result and void any warranties.
3.3.4 NO scheduled maintenance is required to ensure continued
airworthiness.
3.3.5 ESD (Electro Static Discharge) guidelines shall be followed.
3.4
Wiring
Requirements
3.4.1 Introduction
The installing agency must supply and fabricate all external cables
and mating connectors. The length and routing of external cables
must be carefully studied and planned before attempting installation
of the equipment. Allow adequate space for installation of cable
and connectors. Avoid sharp bends and placing cables near
aircraft control cables. Maintain a MINIMUM clearance of three (3)
inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches between the lines.