3.0     Installation 

 

3.1    Prior to Installation 

 
3.1.1 During the design and layout of the aircraft cabin, careful 

consideration of the location of this module is necessary.  Some of 
the items to be considered include: 

 Space 

  Available power supply 

  Environmental conditions (temperature, humidity, etc.) 

  Length of cable runs 

 

3.1.2  The AI-HUB-03-x shall be installed to conform to the standards 

designated by the customer, installing agency, and existing 
conditions as to the unit location and type of installation.  

  
3.1.3 Mounting screws are required to secure the unit.  Refer to  

Section 6.0, Reference Drawings, for mounting hole diameters and 
configuration. 

 

 3.2  Unpacking and Inspection 

 

3.2.1  Carefully open the packaging and remove the AI-HUB-03-x.  Verify 

that all components have been included in the package per the 
packing list.  Inspect the unit for shipping damage. 

 
3.2.2  If damage has occurred during shipping, a claim should be filed 

with Audio International WITHIN 24 hours and a 

Return Request 

Authorization Number 

shall be obtained from AI by contacting the 

Repair Department at 501.801.0640.  Repackage the unit in its 
original packaging materials and return it to AI following instructions 
given by the AI representative.  Refer to the front cover of this 
manual for address.  If no return is necessary, retain the packing 
list and the packing materials for storage. 

 

3.3 

Cautions and Warnings

 

 

3.3.1  It is important to do a pin-to-pin power and ground check on all 

connectors.  Ensure that power and ground are applied only where 
specified.  Damage to the unit may result if power or ground is 
applied to the wrong points. 

 

3.3.2 

DO NOT

 connect or disconnect the module while power is applied. 

 

3.3.3 

DO NOT 

remove any factory-installed screws.  Damage to the units 

may result and void any warranties. 

Содержание AI-HUB-03-x

Страница 1: ...00 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 www audiointl com Installation Manual AI HUB 03 x Data Interface Switch Module Document 540316 a DeCrane Aircraft Compa...

Страница 2: ...Subject Manual Revision Revision Date Table of Illustrations Section Description Page 2 4 Block Diagram Typical Application 5 6 0 Reference Drawings 11 12 PROPRIETARY INFORMATION NOTICE Despite any ot...

Страница 3: ...iagram Typical Application 5 3 0 Installation 6 3 1 Prior to Installation 6 3 2 Unpacking and Inspection 6 3 3 Cautions Warnings 6 3 4 Wiring Requirements 7 3 5 Physical Characteristics 8 3 6 Electric...

Страница 4: ...HUB 03 x provides flexibility in configuring network connections All ports on the switch are 10 100 Mbps Ethernet ports The network access speed for the ports is automatically sensed and displayed on...

Страница 5: ...be used with hubs switches or other interconnection devices in various configurations 2 1 3 The following table describes the activity of the switch LEDs Label Color Activity Description Link located...

Страница 6: ...Audio International Inc AI HUB 03 x Installation Manual Document 540316 Rev IR 03 2006 Page 5 of 12 2 3 Block Diagram Typical Application...

Страница 7: ...that all components have been included in the package per the packing list Inspect the unit for shipping damage 3 2 2 If damage has occurred during shipping a claim should be filed with Audio Internat...

Страница 8: ...upply and fabricate all external cables and mating connectors The length and routing of external cables should be carefully studied and planned before attempting installation of the equipment Allow ad...

Страница 9: ...ical power source bus 3 4 3 Interconnect Wiring 3 4 3 1 Use shielded category 5 CAT 5 cable for all Ethernet connections Use PIC wire and cable 10 100Base T quad 4 conductor cable or equivalent PIC P...

Страница 10: ...Signal Name 1 28 VDC Power Input 2 Ground 3 N C 4 N C 5 N C 6 N C 7 N C 8 N C 9 N C 3 9 Post Installation Test When power has been applied to the unit the green Pwr Power LED on the front panel is on...

Страница 11: ...of the UTP cable from the switch to the device does not exceed 328 feet 100 meters Green FDX LED is off when the port to operate is in full duplex mode Port is operating in half duplex mode Make sure...

Страница 12: ...f 12 5 0 Specifications Physical Specifications Housing Aluminum Weight Approx 1 21 lb 0 55 kg Dimensions l x w x h 6 25 x 10 44 x 1 5 15 9 cm x 26 5 cm x 3 8 cm 6 0 Reference Drawings The following d...

Страница 13: ...Audio International Inc AI HUB 03 x Installation Manual Document 540316 Rev IR 03 2006 Page 12 of 12...