parameter.  The Up or Dn buttons will toggle the display between Alarm On and Alarm Off.  Pressing the
Sel button will change to the time/day display.  The hour, minute and days will be displayed.  The flashing
cursor indicates which parameter may be changed.  Advance to the next parameter by pressing the Sel
button and adjust that parameter using the Up and Dn buttons.  Holding the up/down buttons will continu-
ously scroll through the choices.  For the days, you can choose any single day of the week this alarm will
activate, Saturday or Sunday only, Monday through Friday only, or everyday of the week.  After setting the
day, pressing the Sel button will bring you to the input setting.  The input label corresponding to one of the
sources programmed for this keypad will be displayed with a flashing arrow next to it.  Change to one of
the other sources with the Up or Dn buttons.  You can also choose to perform a ROOM OFF or ALL OFF
for the alarm setting.  The snooze timer is adjustable from 0 to 15 minutes.  Press the Sel button until the
display reads Snooze Set.  Now pressing the Up or Dn buttons will alter the snooze time.  All alarm and
snooze timer settings are immediate.  Once changed you may review them by stepping through the
setting parameters.  Checking the alarm and snooze settings this way may be done at any time even if you
are not making any changes.

When the alarm goes off at the time selected and the alarm is not a room off or all off, any button on the
keypad except off acts as a snooze button. If the snooze time was set to 0 then the alarm will turn off.  If
a time interval of 1-15 minutes was set, the keypad will wait this amount of time and activate the alarm
once again.  Once the alarm goes off, after one hour time, the zone will turn off.  This includes snooze
timer operation.  If the alarm goes off and no button is pressed, the zone will shut down after 1 hour.  If you
want the zone to stay on you must turn the zone off and then back on to cancel the one hour alarm timer.
If the keypad is locked, the snooze function will operate until the alarm mode has been cancelled or times
out, then the keypad will be locked (see keypad lock description).  The alarm settings are stored in non-
volatile memory.  If there is a power failure, once the system is powered again the alarm time will activate
normally.

SLEEP TIMER

The sleep timer counts down the set time period and turns the zone off.  Choose the sleep timer mode by
pressing the Mode button.  Using the Up or Dn buttons to set the sleep timer which is settable in 5 minute
increments up to 60 minutes.  Once a setting is made the timer begins.  To cancel the sleep timer, adjust
until the display shows SLEEP = OFF.

PARTY

This mode lets you temporarily makes the MC-6011 take over source selection for a particular Party
Group.  Rooms are set to track Party Groups in the Suite 8x8 or Suite 16 Setup/Tester PC Program or on
the front of the Suite 8x8.  Though there are currently 4 party modes for Suite 8/16 systems, you may
choose up to party 8 for future Suite systems.  Press the Mode button to advance to Party.  Use the
navigate Up and Dn buttons to choose a Party Group.  Once the desired Party Group is displayed, press
the Sel button.  Arrows will flank the Party Group number (>PARTY #<) and you can now proceed to select
an input for this Party Group by pressing the Up and Dn buttons as one would to normally select an input.
When the desired input is displayed, press the Sel button to engage that input to all zones tracking that
Party Group.  While in the Party mode, the keypad will maintain the selected Party group for ten seconds
and then reset to normal room operation.  Each Party function resets this 10 second timer.

VOLUME SET

The volume set mode lets you choose what volume the room will turn on with.  Press the Mode button until
the display reads VOLUME SET.  Pressing the Dn button will engage VOLUME LAST where the zone will
turn on each time to the last used volume.  Pressing the Up button will store the current volume into
volume preset 1 and set the Suite 8/16 to VOLUME PSET1.  With this setting the zone will turn on with the
volume setting stored in volume preset one, as well as the settings stored in Tone Preset 1 and Balance
Preset 1.

Содержание MC-6011

Страница 1: ...e Options 4 TONE CONTROL 4 TONE PRESETS 4 ALARM CLOCK 4 SLEEP TIMER 5 PARTY 5 VOLUME SET 5 ROOM SCAN 6 KEYPAD LOCK 6 SETUP MENUS 8 0000 RESET KEYPAD LOCK CODE 8 1110 NIGHT LIGHT ON AND OFF TOGGLE 8 11...

Страница 2: ...etely off All Off the Off button is green It is red only when the zone is off but another zone s is still on To turn off the entire system press and hold the Off button until it flashes Turning on a z...

Страница 3: ...automatically tune to the first XM channel in that Genre If you select a specific channel using the button then the Tune Suite will automatically tune to that channel a moment after it has been displa...

Страница 4: ...e set to display Alarm Clock and Sleep Timer while the one in the dining room does not display these options This makes it possible for you to tailor the system to your needs TONE CONTROL When in the...

Страница 5: ...nt the zone to stay on you must turn the zone off and then back on to cancel the one hour alarm timer If the keypad is locked the snooze function will operate until the alarm mode has been cancelled o...

Страница 6: ...system to show the current status for inputs and second source functions but will not allow any buttons to function The setup menus are still accessible when a keypad is locked A user settable 4 digi...

Страница 7: ...m the setup menu Press and hold the MODE button for 5 seconds until CODE _ _ _ _ is displayed Using the number Up button enter 0 If you passed 0 you can use the Dn button to go back When 0 is displaye...

Страница 8: ...F If the keypad needs to be as dark as possible even when the zone or any other zone is on see blanking mode under code 1113 1111 KEYPAD TEST MODE The MC 6011 can be set to a test mode in which pressi...

Страница 9: ...e button to advance to SET DATE and use the and buttons to select the proper date Press the button to SET DAY and use the and buttons to set the right day of the week Press the button to SET 12 24 HR...

Страница 10: ...RTYGROUP 4 PARTYGROUP 5 PARTYGROUP 6 PARTYGROUP 7 PARTYGROUP 8 Please note than not all Suite systems have all eight Party Groups Most have only four Party Groups By pressing or you will be able to ad...

Страница 11: ...fer to no source selection at all If an IN SOURCE is set to INPUT 0 then it will be skipped over If for example input labels 7 16 IN SOURCE 7 16 are all set to INPUT 0 then the keypad will only scroll...

Страница 12: ...s 1 modules 1 3 and the fourth module is set under address 2 module 1 Note that this address setting is not directly tied to the Tune Suite s rotary dip switch address selector as the Tune Suite s 16...

Страница 13: ...s of the sources that are connected to the Suite 16 or Suite 8x8 The keypad s display can read up to eleven characters This permits you to define that component by name Whether you are using eight or...

Страница 14: ...max room number Changes are immedi ate To exit press the button Check Setup When CHECK SETUP is displayed press the to verify keypad source buttons to input connection source input label number sourc...

Отзывы: