Additional Feature Options

The Mode button chooses alternate functions for the MC-6011 buttons.  The eight main functions are:

1.

Tone Controls

2.

Tone Presets

3.

Alarm Clock (Requires CMB-1 System Clock)

4.

Sleep Timer

5.

Party

6.

Volume Set

7.

Room Scan

8.

Keypad Lock

Entering any of these modes starts a 10 second timer in the keypad.  If a button is not pressed within that
time, the MC-6011 will exit the Mode option and return to displaying source information.  After the Keypad
Lock mode, pressing the MODE button once again will display EXIT, the same as letting the timer time-
out.  Please note that pressing and holding the Mode button will prompt you to enter a code to access the
MC-6011’s setup options.

NOTE:  Some of the modes may not show up while pressing the mode button.  When the zone is off only
alarm clock, room scan and keypad lock will display.  If the CMB-1 clock module is not connected to
the ADA bus or the control never received a clock calibration, the alarm function will never show
on the display.
  Also, like the MC-4500 and MC-5500, some or all of these eight features can be elimi-
nated from being displayed on the keypad.  This setup can be specific to individual keypads.  For ex-
ample, an MC-6011 in the bedroom might be set to display Alarm Clock and Sleep Timer, while the one in
the dining room does not display these options.  This makes it possible for you to tailor the system to your
needs.

TONE CONTROL

When in the tone control mode, the Sel button will cycle through the various tone controls and update the
current setting.  The Up and Dn buttons will adjust the selected tone control (These include bass, midrange,
treble, loudness contour and stereo enhance for the Suite 8; no midrange for the Suite 16.  There is an
automatic feature that adds midrange to the selection menu when used with a Suite 8x8 and new Suite
16’s set to ship in 2005).

TONE PRESETS

In tone presets mode, the Sel button advances through the four tone presets, recalling them as the preset
number is displayed.  For the Suite 8x8, there is an option to set the tone controls to flat.

ALARM CLOCK

NOTE: the alarm function will not display if the system does not have a CMB-1 clock module or if
the keypad was plugged in after system power-up and a clock calibration was not received.

Under the alarm clock menu there are three sub-menus; Alarm 1, Alarm 2 and Snooze Timer.  Each alarm
allows the setting of time, days and input.  The snooze timer is common for both alarms and increments by
minutes up to 15 minutes.  The time setting hour format (12/24) is the same as what the keypad is set to
for its clock display.

After choosing the Alarm Clock mode, press the Sel button to display ALARM 1 SET, ALARM 2 SET, or
SNOOZE SET.  For an alarm setting, press the Up button.  If alarm 1 was used the display will change to
ALARM 1 ON, telling you if this alarm is active.  The O of ON or OFF will flash, indicating this is a settable

Содержание MC-6011

Страница 1: ...e Options 4 TONE CONTROL 4 TONE PRESETS 4 ALARM CLOCK 4 SLEEP TIMER 5 PARTY 5 VOLUME SET 5 ROOM SCAN 6 KEYPAD LOCK 6 SETUP MENUS 8 0000 RESET KEYPAD LOCK CODE 8 1110 NIGHT LIGHT ON AND OFF TOGGLE 8 11...

Страница 2: ...etely off All Off the Off button is green It is red only when the zone is off but another zone s is still on To turn off the entire system press and hold the Off button until it flashes Turning on a z...

Страница 3: ...automatically tune to the first XM channel in that Genre If you select a specific channel using the button then the Tune Suite will automatically tune to that channel a moment after it has been displa...

Страница 4: ...e set to display Alarm Clock and Sleep Timer while the one in the dining room does not display these options This makes it possible for you to tailor the system to your needs TONE CONTROL When in the...

Страница 5: ...nt the zone to stay on you must turn the zone off and then back on to cancel the one hour alarm timer If the keypad is locked the snooze function will operate until the alarm mode has been cancelled o...

Страница 6: ...system to show the current status for inputs and second source functions but will not allow any buttons to function The setup menus are still accessible when a keypad is locked A user settable 4 digi...

Страница 7: ...m the setup menu Press and hold the MODE button for 5 seconds until CODE _ _ _ _ is displayed Using the number Up button enter 0 If you passed 0 you can use the Dn button to go back When 0 is displaye...

Страница 8: ...F If the keypad needs to be as dark as possible even when the zone or any other zone is on see blanking mode under code 1113 1111 KEYPAD TEST MODE The MC 6011 can be set to a test mode in which pressi...

Страница 9: ...e button to advance to SET DATE and use the and buttons to select the proper date Press the button to SET DAY and use the and buttons to set the right day of the week Press the button to SET 12 24 HR...

Страница 10: ...RTYGROUP 4 PARTYGROUP 5 PARTYGROUP 6 PARTYGROUP 7 PARTYGROUP 8 Please note than not all Suite systems have all eight Party Groups Most have only four Party Groups By pressing or you will be able to ad...

Страница 11: ...fer to no source selection at all If an IN SOURCE is set to INPUT 0 then it will be skipped over If for example input labels 7 16 IN SOURCE 7 16 are all set to INPUT 0 then the keypad will only scroll...

Страница 12: ...s 1 modules 1 3 and the fourth module is set under address 2 module 1 Note that this address setting is not directly tied to the Tune Suite s rotary dip switch address selector as the Tune Suite s 16...

Страница 13: ...s of the sources that are connected to the Suite 16 or Suite 8x8 The keypad s display can read up to eleven characters This permits you to define that component by name Whether you are using eight or...

Страница 14: ...max room number Changes are immedi ate To exit press the button Check Setup When CHECK SETUP is displayed press the to verify keypad source buttons to input connection source input label number sourc...

Отзывы: