8
9
Serial Commands
Code
Definition
POWER 00
Power off (standby)
POWER 01
Power on
PORT 11
Zone 1, select Source 1
PORT 12
Zone 1, select Source 2
PORT 13
Zone 1, select Source 3
PORT 14
Zone 1, select Source 4
PORT 21
Zone 2, select Source 1
PORT 22
Zone 2, select Source 2
PORT 23
Zone 2, select Source 3
PORT 24
Zone 2, select Source 4
PORT 31
Zone 3, select Source 1
PORT 32
Zone 3, select Source 2
PORT 33
Zone 3, select Source 3
PORT 34
Zone 3, select Source 4
PORT 41
Zone 4, select Source 1
PORT 42
Zone 4, select Source 2
PORT 43
Zone 4, select Source 3
PORT 44
Zone 4, select Source 4
6.2 IR Remote Control
The four rows of source selector
buttons just below the power
button are used to select the
source on the four zone outputs.
Each row represents a zone.
6.3 RS-232 Control
Connect a computer or other
serial controller to the RS-232
port on the rear panel using a
cable with pin connections as
shown on page 6. Commands
include on, off, and source
selection on any zone output.
Important:
all serial commands
must be terminated with a
carriage return and line feed.
RS-232 Transmission Format
Baud Rate: 9600 bps
Data bit: 8 Bits
Parity: None
Stop Bit: 1 bit
OUTPUT
OUTPUT
OUTPUT
OUTPUT
POWER
ZONE 1
ZONE 2
ZONE 3
ZONE 4
SOURCES
IR Remote
Control
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4