![Audio Analogue Crescendo Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/audio-analogue/crescendo/crescendo_owners-manual_3007772019.webp)
19
TROUBLESHOOTING
Symptom
Cause
Remedy
Power cord incorrectly plugged in
Make sure the power cord is correctly
plugged into the wall outlet
No led on
No sound
Burned-out fuses
Check fuses in the fuse panel above
the IEC inlet (after unplugging the
power cord from the wall outlet)and
replace them with new ones of the
same type
Low volume
Turn volume knob right
Faulty or incorrectly plugged signal
connectors between integrated amp. and
the sources
Check cords and their connection
Off or incorrectly selected source
Check if the source is on and active
and if it is correctly selected using the
in selector
Only one input led is on
No sound
Faulty or incorrectly plugged power cords
between the integrated amplifier and the
speakers
Check cords and their connection
Selected in leds are on, volume control
works but the leds are off, or selected in
leds are off and volume leds are on
Faulty or incorrectly plugged front panel
Contact your Audio Analogue retailer
for connections check and front panel
substitution
Recording is impossible
Incorrectly selected source
Select the right source using the
recording selector and increase the
volume above 0 level
Remote controller doesn’t work
No battery/ worn-out battery
Place/replace battery (2 ‘AAA’
batteries)
You’re standing too far or on an exceeding
angle from the front panel
Get closer to the unit or reduce angle
Selected in leds are on, volume control
works but the leds are off, or selected in
leds are off and volume leds are on
Faulty or incorrectly plugged front panel
Contact your Audio Analogue retailer
for connections check and front panel
substitution
If the suggested remedies do not work or the problem is not shown in the list above, please contact your local Audio
Analogue retailer.