![Audient DLC ASP8024-DLC Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/audient/dlc-asp8024-dlc/dlc-asp8024-dlc_user-manual_3007655008.webp)
8
MAC Installation
Page right again to reach the
IP address screen and use the
encoders to set the IP address to:
192 . 168 . 100 . X
(ensuring that ‘X’ is different to
that of the computer).
On the following pages, set the
Subnet Mask to:
255 . 255 . 255 . 0
Then set the Port to:
1212
Press the Setup Button again
to exit setup and save these
settings.
SETTING AUTOMATIC IP ADDRESS (USING DHCP)
If you have connected DLC to a network using DHCP to automatically assign IP addresses,
then you will need to set DLC to use DHCP.
On the second page of the Setup Menu, ensure that the Use DHCP option is set to
YES
,
and that your Mac is configured to use DHCP in the Network System Preferences (by
default your Mac should be set to use DHCP).
Press the Setup Button again to exit setup and save these settings.
Connected
Disconnected
DLC CONNECT
Once network settings have been finalised,
reboot the console and the computer. On
rebooting, DLC Connect should open and
the console should be listed. Highlight
the console within the app, and click the
connect button.
Your DLC module should now be
connected to your Mac and ready for
configuration as a HUI control surface and
analogue automation platform.
The DLC connect app icon in the menu bar
will display the connectivity status, with
a black icon indicating DLC is connected,
and a greyed out icon indicating DLC is
disconnected.