background image

USER´S

MANUAL

Aurora 

150T

3

8

Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate 

ventilation. Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it 

where it can be moved or fall over. If you install the fixture in a location where it may cause 

injury or damage if it falls, secure it as directed in this user manual using a securely anchored 

safety cable that will hold the fixture if the primary fastening method fails.

Fastening the fixture to a flat surface

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure 

that the surface and all fasteners used can support at least 10 times the weight of all fixtures 

and equipment to be installed on it.

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or 

fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 

secure it as directed below with a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When 

installing the fixture hanging vertically down, you can use an open-type clamp such as a 

G-clamp. When installing in any other orientation, you must use a half-coupler clamp that 

completely encircles the truss chord.

To clamp the fixture to a truss:

1. Check that the rigging structure can support at least 10 times the weight of all fixtures and 

equipment to be installed on it.

2. Block access under the work area.

3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the 

mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through 

both mounting bracket legs and be fastened with a self-locking nut.

4. Working from a stable platform, hang the fixture with its clamp on the truss and fasten the 

clamp securely.

5. Secure the fixture with a safety cable as directed below.

With RDM function, you can set the DMX address of your fixtures remotely. This is especially 

useful when the device is installed in a remote area.

Each Aurora 150T has a factory set RDM UID (unique identification number).

Note: 

Before operation, enable RDM function in Advanced settings.

Rotary Knob function

The knob in the rear panel of the Aurora 150T act as multi-function. Including rotary control 

of dimmer, rotary control of dimmer, up/down/enter function.

Dimmer function:

1. Press the MENU button to enter the main menu.

2. Press the UP or DOWN button to select Mode menu and press ENTER.

3. Press DOWN menu and select Manual sub menu.

4. Press ENTER and select Brightness or Strobe in third menu.

5. Rotate the rotary knob to control the dimmer (right stop = maximum output, left stop = 

zero output), or strobe (right stop = maximum strobe, left stop = no strobe).

Note:

 Rotary dimmer or strobe function works in information Menu and Mode-Manual menu.

Up, Down, Enter function:

The knob can also act as up, down and enter function.

1. Press the MENU button to enter the main menu interface.

2. Right rotation = Down, left rotation = Up, press = Enter function.

Set dimmer curves

This function allows you to select preset dimmer curves as well as custom dimmer curves.

Menu 

DMX

 

Mode

 

Dimmer

 

 

Advance

 

 

Menu>Dimmer 

Curve 

Mode 

1.0

 

 

 

 

 

Standard 

 

 

 

 

 

Stage 

 

 

 

 

 

TV 

 

 

 

 

 

Architecture 

 

 

 

 

 

Theatre 

 

 

 

 

 

 

Advance

 

  

Dimmer 

 

Mode

 

DMX

 

Menu 

Содержание 7427244398602

Страница 1: ...Aurora 150T Please read the manual before using the product USER S MANUAL 11 Aurora 150T Notes ...

Страница 2: ... gent solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Troubleshooting Listed below are a few common problems that you may enco...

Страница 3: ...y sharp edges Check the fixture and the power cord from time to time Make sure to replace the fuse with another of the same type and rating For your own safety please read this user manual carefully before your initial start up Follow operating safety precautions and pay attention to warning signs methods and equipment on the user manual Warning This symbol indicates a hot surface Certain parts of...

Страница 4: ... the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3 Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket The bolt used must be M10 grade 8 8 steel minimum It must pass through both mounting bracket legs and be fastened with a self locking nut 4 Working from a stable platform hang the fixture with i...

Страница 5: ...50T 7 4 DMX OUT 1 Ground 2 Signal 3 Signal DMX IN 1 Ground 2 Signal 3 Signal Addressing All fixtures should be given a DMX starting address when using a DMX signal so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allo...

Страница 6: ...ge TV Dimmer mode TV Architecture Dimmer mode Architecture Theatre Dimmer mode Theatre Studio Less power lower fan speed Turbo Turbo mode 300W output max Custom Fade in 150 ms 2230 ms Custom dimmer curve Fade out 150 ms 2230 ms Advance Authorization On Off Advanced settings calibration Onlyqualified technicians should perform this function Inquire your local dealer for password Signal Priority DMX...

Страница 7: ...Aurora 150T Por favor lea el manual antes de usar el producto MANUAL DE USUARIO 11 Aurora 150T Notas ...

Страница 8: ... fuerza levante las partículas con una presión suave y repetida Seque con un paño suave limpio y sin pelusa o con aire comprimido a baja presión Retire las partículas adheridas con un pañuelo de papel sin perfume o un bastoncillo de algodón humedecido con limpiacristales o agua destilada 4 Verifique que el accesorio esté seco antes de volver a aplicar energía Solución de problemas A continuación s...

Страница 9: ... mismo tipo y clasificación Por su propia seguridad lea detenidamente este manual de usuario antes de la puesta en marcha inicial Siga las precauciones de seguridad operativas y preste atención a los métodos y equipos de advertencia en el manual del usuario Advertencia Este símbolo indica una superficie caliente Ciertas partes de la carcasa pueden calentarse durante el funcionamiento Después del u...

Страница 10: ...o debajo del área de trabajo 3 Doble las patas del soporte de montaje y atornille firmemente una abrazadera de montaje al soporte de montaje El perno utilizado debe ser de acero M10 grado 8 8 como mínimo Debe pasar a través de ambas patas del soporte de montaje y sujetarse con una tuerca autoblocante 4 Trabajando desde una plataforma estable cuelgue la luminaria con su abrazadera en el truss y suj...

Страница 11: ...150T 7 4 SALIDA DMX 1 Tierra 2 Señal 3 Señal ENTRADA DMX 1 Tierra 2 Señal 3 Señal Direccionamiento Todos los dispositivos deben recibir una dirección de inicio DMX cuando se utiliza una señal DMX de modo que el dispositivo correcto responda a las señales de control correctas Esta dirección de inicio digital es el número de canal desde el cual el dispositivo comienza a escuchar la información de co...

Страница 12: ...icite la contraseña a su distribuidor local Signal Priority DMX Configuración de prioridad de señal DMX Signal Hold On Off Ejecutar si se corta la señal Advance RDM On Off Función RDM activada desactivada Screen Timeout 30S Hora de apagado de la pantalla Never Screen Brightness 25 100 Brillo de la Pantalla Dimming Freq 1 20KHz Ajuste de frecuencia de atenuación 1 60KHz 2 40KHz 4 00KHz 6 00KHz 20 0...