Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Note
♦
A working network connection is necessary to send the diag‐
nostic log file online.
♦
After the diagnosis is complete, you will receive confirmation
that the test log was sent successfully.
3.7
Battery: checking that battery and bat‐
tery cables are securely fitted
3.7.1
All models except A8 hybrid
WARNING
Risk of injury due to loose battery clamp on positive terminal.
♦ Disconnect battery clamp from negative terminal and then
tighten battery clamp on positive terminal.
Special tools and workshop equipment required
♦ Torque wrench - V.A.G 1410- , measuring range 4 to 20 Nm
♦ Or: torque wrench - VAS 6583- , measuring range 3 to 60 Nm
Table of tightening torques for installation:
Component/fastener
[Nm]
Nut on battery clamp
4
Bolt on retainer plate
18
The battery is located in the luggage compartment.
Requirements:
• Ignition switched off during test.
Removal steps:
– Lift luggage compartment floor and secure in position.
– Remove spare wheel (where applicable).
– If fitted, take out tool box.
– Open battery terminal covers.
Audi A8 2010 ➤
Maintenance - Edition 11.2014
30
3. Maintenance