OVERVIEW 

The  AM004  /X  is  a  2/4  power  amplifier,  it  has 
separated  connection  to  use  it  as  2  channels  or  4 
channels  amplifier.  It  could  be  used  also  as  2  ohm  2 
channels amplifier, paring the channels (PTL - Parallel 
Tied Load). The system has balanced inputs with XLR 
connectors and speakon connector for power outputs. 
Also  the  power  supply  cord  is  with  speakon  type 
connector to ensure a stable connection.  
 

FRONT PANEL 

In the front panel is located: 
(1)

 

Power switch. 

(2)

 

Protection LED for channels pair, indicate that the 
amplifier is in a protection state as protection for 
some  electrical  trip.  Ensure  that  there  are  not 
wiring problem and restart the device. 

 

 

 

(3)

 

Main  volume  regulation,  this  KNOB  regulates 
the output level of the amplifier channels 

(4)

 

VU  METER,  this  METER  indicates  the  output 
sound level.  

(5)

 

Normal  to  bridge  selector,  set  on  bridge  to  use 
the  amplifier  as  2  channels  and  high  current  2 
channels  mode,  more  info  for  last  solution  in 
the PTL (Parallel Tied Load) chapter. 

 

REAR PANEL 

In  the  rear  panel  there  are  all  the  connection 
interface. Following the details: 

(1) The power supply inlet (speakon) 
(2)  2  channel  mode  (bridge)  output  connectors, 
speakon 2 pin type. To use this set the switch in the 
front  panel  in  bridge  mode  (see  bridge  mode 
capter). 
(3)  4  channels  mode  output  connectors,  speakon  4 
pin connectors, pin 3 and 4 are required only in PTL 
(Parallel Tied Load) mode. 
(4) Line inputs, XLR balanced type 

 

 

 

The power supply inlet and the power supply specifics change according to countries standards; until 
to  connect  the  AC  cord  to  the  power  source  please  verify  that  the  supply  voltage  and  frequencies 
printed on the rear panel are coincident with the local electrical system specifics. 

Содержание AM004x

Страница 1: ...MNAM004x R00 EN AUDEIA AM004 x 2 4 channels amplifier USER MANUAL Revision 0 2021 March EN www audeia com ...

Страница 2: ...of fire or electric shock do not expose this apparatus to rain or moisture Only use attachments accessories specified by the manufacturer Refer all servicing to qualified personnel To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Servicing is required when the apparatus has been damaged in an...

Страница 3: ...STRUCTIONS 2 DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT 2 INCLUDED ITEMS 4 ABOUT THIS MANUAL 4 LEGAL DISCLAIMER 4 PRECAUTION FOR INSTALLATION AND USE 4 WARRANTY 4 OVERVIEW 5 FRONT PANEL 5 REAR PANEL 5 CONNECTIONS 6 PTL Parallel Tied Load 6 Bridge mode 6 TECHNICAL SPECIFICS 7 ...

Страница 4: ...on places exposed to rain or other water Do not place anything on the unit Do not expose to fast reduction of temperature because condensation could occur with possible damaging of the apparatus If this happen leave the unit for one or two hours before turning the unit on Avoid installing this unit on top of any heat generating devices as power amplifiers also to avoid condensation To clean the un...

Страница 5: ...he amplifier channels 4 VU METER this METER indicates the output sound level 5 Normal to bridge selector set on bridge to use the amplifier as 2 channels and high current 2 channels mode more info for last solution in the PTL Parallel Tied Load chapter REAR PANEL In the rear panel there are all the connection interface Following the details 1 The power supply inlet speakon 2 2 channel mode bridge ...

Страница 6: ...lel Tied Load The PTL mode let you to have 2 channels that are able to support 2 Ohm load For this type of configuration you have to make a specific wiring Firs of all in the speakons of the channels 1 and 2 a connection is required in the pin 3 and 4 to short them together After that you have to connect outputs 1 and 3 and outputs 2 and 4 in parallel as shown in the following picture The inputs m...

Страница 7: ...5 264 V AC Power Factor cos 0 9 4 Ω full power Consumption Standby 2 a W Idle 10 W Rated Load 1 4 Max Power 150 W AC Current Nominal 1 5 A Max 7 A Inrush Current 18 Audio Gain 26 dB Input 3 pole XLR balanced Output normal PTL 2x2 pole and 2x4 pole speakon Output bridge 2x2 pole speakon Frequency Response 1 dB 1 W 8 Ω 10 Hz 30 kHz Noise Floor Typical 80 dBV A Crosstalk Separation 1 kHz Typical 70 d...

Страница 8: ...www audeia com ...

Отзывы: