background image

SAFETY PRECAUTION 
 

 
 

AUDEIA - 

AM004

 /x – USER MANUAL - EN 

2

SIMBOLS 

 

 

 

 
The  lightning  flash  with  arrowhead 
symbol (as the one in the left) is intended 
to  alert  the  user  to  the  presence  of 
dangerous  voltage  within  the  product 
enclosure  that  may  constitute  a  risk  of 
electric shock to person.  
The 

exclamation 

point 

within 

an 

equilateral  triangle  (as  the  one  in  the 
left),  is  intended  to  alert  the  user  to  the 
presence 

of 

important 

instruction 

concerning the use of the appliance. 

 

SAFETY INSTRUCTIONS 

 

Read these instructions 

 

Keep these instructions 

 

Heed all warnings 

 

Trail all instructions 

 

Do not use this apparatus near water 

 

Clear only with dry cloth 

 

Install 

in 

accordance 

with 

the 

manufacturers 

instructions 

 

Do  not install  near  any  heat  sources  such  as  radiators, 
heat  registers,  stoves,  or  other  apparatus  (including 
amplifiers) that produce heat 

 

No naked flame sources, such as lighted candles, should 
be placed on the apparatus. 

 

Do not block any ventilation openings. 

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or 
grounding type plug 

 

Ensures  the  source  voltage  matches  the  voltage  of  the 
power supply before turning ON the apparatus. 

 

If  the  provided  plug  does  not  fit  into  your  outlet, 
consult  an  electrician  for  replacement  of  the  obsolete 
outlet. 

 

Protect  the  power  cord  from  being  walked  on  or 
pinched  particularly  at  the  plug,  convenience 
receptacles,  and  the  point  where  they  exit  from  the 
apparatus. 

 

Unplug this apparatus during lightning storms or when 
unused for long periods of time. 

 

There are maybe some areas with high voltages inside, 
to reduce the risk of electric shock, do not remove any 
cover  if  the  power  supply  is  connected.  The  cover 
should be removed by qualified personnel only. No user 
serviceable parts inside. 

 

This  apparatus  shall  not  be  exposed  to  dripping  or 
splashing and that no objects filled with liquids, such as 
vases, shall be placed on this apparatus. 

 

To  reduce  the  risk  of  fire  or  electric  shock,  do  not 
expose this apparatus to rain or moisture. 

 

Only  use  attachments/accessories  specified  by  the 
manufacturer. 

 

Refer all servicing to qualified personnel. To reduce the 
risk  of  electric  shock,  do  not  perform  any  servicing 
other than that contained in the operating instructions 
unless you are qualified to do so. 

 

Servicing  is  required  when  the  apparatus  has  been 
damaged in any way, such as the power supply cord or 
plug is damaged, liquid has been spilled or objects have 
fallen  into  the  apparatus,  the  apparatus  has  been 
exposed to rain or moisture, does not operate normally, 
or has been dropped.  

 

Make  sure  to  connect  the  protective  grounding  to 
prevent  any  electric  shock  before  turning  ON  the 
apparatus. 

 

The external wiring connected to the output hazardous 
live  terminals  requires  installation  by  an  instructed 
person, or the use of ready-made leads or cords. 

 

Never  cut  off  the  internal  or  external  protective 
grounding  wire  or  disconnect  the  wiring  of  protective 
grounding terminal. 

 

DISPOSAL OF ELECTRICAL AND 

ELECTRONIC EQUIPMENT 

 

All  the  electrical  and  electronic  equipment  should  be 
disposed  separately  from  the  municipal  waste  via 
collection facilities designed by the government or local 
authorities. 

 

By  disposing  of  electrical  and  electronic  equipment 
correctly  you  help  to  save  valuable  resources  and 
prevent any potential negative effects on human health 
and the environment. 

 

Improper  disposal  of  waste  electrical  and  electronic 
equipment  can  have  serious effect  on  the environment 
and human health because of the presence of hazardous 
substances in this type of equipment. 

 

The 

waste 

electrical 

and 

electronic 

equipment 

(WEEE) 

symbol, which show a bin that has 
been  crossed  out,  indicates  that 
electrical 

and 

electronic 

equipment  must  be  collected  and 

disposed of separately from household waste. 

 

Return  and  collection  systems  are  available  to  end 
users. For more detailed information about the disposal 
of  old  electrical  and  electronics  equipment,  please 
contact your city office of waste disposal service or the 
shop where you purchased the equipment. 

Содержание AM004x

Страница 1: ...MNAM004x R00 EN AUDEIA AM004 x 2 4 channels amplifier USER MANUAL Revision 0 2021 March EN www audeia com ...

Страница 2: ...of fire or electric shock do not expose this apparatus to rain or moisture Only use attachments accessories specified by the manufacturer Refer all servicing to qualified personnel To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Servicing is required when the apparatus has been damaged in an...

Страница 3: ...STRUCTIONS 2 DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT 2 INCLUDED ITEMS 4 ABOUT THIS MANUAL 4 LEGAL DISCLAIMER 4 PRECAUTION FOR INSTALLATION AND USE 4 WARRANTY 4 OVERVIEW 5 FRONT PANEL 5 REAR PANEL 5 CONNECTIONS 6 PTL Parallel Tied Load 6 Bridge mode 6 TECHNICAL SPECIFICS 7 ...

Страница 4: ...on places exposed to rain or other water Do not place anything on the unit Do not expose to fast reduction of temperature because condensation could occur with possible damaging of the apparatus If this happen leave the unit for one or two hours before turning the unit on Avoid installing this unit on top of any heat generating devices as power amplifiers also to avoid condensation To clean the un...

Страница 5: ...he amplifier channels 4 VU METER this METER indicates the output sound level 5 Normal to bridge selector set on bridge to use the amplifier as 2 channels and high current 2 channels mode more info for last solution in the PTL Parallel Tied Load chapter REAR PANEL In the rear panel there are all the connection interface Following the details 1 The power supply inlet speakon 2 2 channel mode bridge ...

Страница 6: ...lel Tied Load The PTL mode let you to have 2 channels that are able to support 2 Ohm load For this type of configuration you have to make a specific wiring Firs of all in the speakons of the channels 1 and 2 a connection is required in the pin 3 and 4 to short them together After that you have to connect outputs 1 and 3 and outputs 2 and 4 in parallel as shown in the following picture The inputs m...

Страница 7: ...5 264 V AC Power Factor cos 0 9 4 Ω full power Consumption Standby 2 a W Idle 10 W Rated Load 1 4 Max Power 150 W AC Current Nominal 1 5 A Max 7 A Inrush Current 18 Audio Gain 26 dB Input 3 pole XLR balanced Output normal PTL 2x2 pole and 2x4 pole speakon Output bridge 2x2 pole speakon Frequency Response 1 dB 1 W 8 Ω 10 Hz 30 kHz Noise Floor Typical 80 dBV A Crosstalk Separation 1 kHz Typical 70 d...

Страница 8: ...www audeia com ...

Отзывы: