Specifications
Microphone type
Dynamic
Polar pattern
Cardioid
Frequency response
80 Hz - 12 kHz
Sensitivity
-72 dB ± 3 dB
Impedance
600 Ohm
Output connections
3-pin XLR
3 connection leads (Chime)
Connection cable
1.5 meter
Dimensions
162 x 122 x 368 mm
Weight
960g
Connecting the PDM200
When connecting the PDM200 to an AUDAC COM12/24 Public Address
amplifier using the integrated chime module of the COM12/24, the microp-
hone should be connected to the “Remote Mic” input according to the diagram
shown below:
Connect the
1) Shield (Pin 1 of XLR) to the G (Ground) terminal
2) Red wire (Pin 2 of XLR) to the H (Hot) terminal
3) Black wire (Pin 3 of XLR) to the C (Cold) terminal
4) Blue wire of the chime circuit to the G (Ground) terminal
5) Green wire of the chime circuit to the SW (Switch) terminal