AVD:
Connections AVD08:
24V DC: The system needs 24V DC power. See part “Power supply and pin configuration” for
more explanation.
Common switch signal: To connect the common signal you want to switch (e.g. 24V DC or
Paging signal).
Output Signal: Where the common input signal is switched to.
Analogue relays activation: This makes it possible to activate relays by pulling the contact to
ground (e.g. with push button).
2 x RJ45 (data bus): The data bus and DC power of all modules are distributed through the CAT5
cable. To guarantee proper operation, the cabling must be “Daisy-chain”. The front and end of the
bus must be terminated with a resistor (+-120 Ohm). This can be done on the last RJ03-splitter
module by setting a jumper (see further in this manual for more information).
24V DC
2x CAT5 (Data bus)
Output signal
Analogue relay
activation