background image

Copyright 2007-2016, Auber Instruments Inc. All Rights Reserved. 

No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Auber Instruments.   

Auber Instruments retains the exclusive rights to all information included in this document.

 

Quick Guide for WSD-1501GPH   

Programmable PID Temperature Controller with Dual Probe

*

 

Version 1.0 (September, 2016) 

Auber Instruments 

5755 North Point Parkway, Suite 99 

Alpharetta, GA 30022 

770-569-8420 

www.auberins.com 

Introduction 

Thank you for purchasing the Auber WS series temperature controller. We sincerely 
appreciate your decision and trust that our machine will meet your expectations in both 
the quality of the result and the value of our product. While we are delighted that you may 
be anxious to operate the controller for your project, a few minutes of your time reading 
through this manual will only serve to enhance your experience in the months and years 
ahead. In particular, we urge you to read through the safety warnings below. Although 
this plug-and-play controller is very easy to operate, the process involves high 
temperature and high wattage appliances and your safety is paramount. 

  SAFETY WARNINGS 

 

 

This controller is designed only to be used with devices that have limited power 
and their own thermal cut off protection, such as a thermostat or thermal fuse in 
case of controller failure.   

 

Do not place any objects on the top of controller surface which is used to vent 
excess heat during its operation.   

 

The maximum electric current this controller can handle is 15 ampere. For 120 
volt AC in US and Canada, this limits the heater power to 1800 watts. 

 

 

Always place the sensor in the controlled subject when the controller is on. Before 
turning on the controller, please make sure the sensor is placed inside the 
container to be controlled. Leaving the sensor outside of the solution will form an 
open loop operation. If the sensor is left outside, controller will assume the 
temperature is low even if the controlled subject is already very hot. The controller 
will provide full power to the heater. It will not only overheat the controller, but also 
damage your appliance, and even cause a fire.   

 

This controller is designed to control the devices recommended by Auber 

                                                        

*

  Patent pending 

Содержание WSD-1501GPH

Страница 1: ...is plug and play controller is very easy to operate the process involves high temperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to b...

Страница 2: ...or low limit alarm of probe 1 is on this window will flashing between the alarm type AH1or AL1 and the temperature In the parameter setting mode it displays the controller s system parameters 2 TEMP2...

Страница 3: ...he parameter setting mode During normal operation press it to cancel the alarm 8 Key To increment displayed value when in controller is in the parameter setting mode During normal operation press it w...

Страница 4: ...enough so that it does not touch the food See Error Reference source not found The tip of probe 2 is to be inserted into the meat Figure 3 Sensor position Left the sensor should be placed close to the...

Страница 5: ...outlet you should use the power cord that came with the Bradley Smoker for connecting the smoker generator to the power outlet b Connecting the controller to the smoker generator You should use the p...

Страница 6: ...the Bradley Smoker Tower with the power cord that came with the Auber Controller Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal Temp Cable A Cable B To Power Outl...

Страница 7: ...oker generator should be connected directly to the wall outlet Connect the controller output with the smoker tower Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal T...

Страница 8: ...l show C 1 at the left window and temperature setting on the right window for step 1 Use and keys to change the setting When finished press the SET again to confirm the change The display will show E...

Страница 9: ...e To check which step the program is at during cooking press the Key 8 once The left window will show the current step in the form of P0X on e g It will display P03 if the controller is at step 3 The...

Страница 10: ...ter in the smoker c Damper position Keeping the damper open will result in better temperature stability because more heat loss is created This is important when the temperature is set below 140 F When...

Страница 11: ...1 this is the high limit alarm for probe 1 User can set the temperature so that if the system is out of control the buzzer will be turned on e g If AH1 set to 290 the buzzer will be on at 291 and off...

Страница 12: ...ht window will show 0 Use the or key to adjust the value to 2 the passcode for saving the program and then press SET key to confirm Then SAV will be shown on the left window and End on right window If...

Страница 13: ...exit In single step mode the save and recall function Section 9 can still work But the change can only be applied to C 1 i e you can only store your current set temperature to the C 1 in a selected r...

Страница 14: ...o confirm and exit Now the C 1 from the recipe b2 is recalled back to your current program The controller will start run at this temperature setting e Advanced example This example will show you how t...