Auber Instruments EZboil DSPR320 Скачать руководство пользователя страница 2

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2018.08                                                                    

   

                                                              P2/11 

 

1

2

3

13

14

6

7

8

9

10

4

5

AL1

AL2

AC

85~260V

SSR

+

-

RTD

R

R

W

 

Figure 2. Terminal assignments of DSPR320.  

 
 
Table 4. Back terminals of DSPR320. 

Pin # 

Descriptions 

Relay 1 (AL1) 


Probe input (PT100 RTD). Two red leads should be connected to pin 3 
and 4.   



Control output (12 VDC), pin 7 is the positive and pin 6 is the negative.  


Power input (85 V ~ 260 V AC) 

10 
13 

Relay 2 (AL2) 

14 

 
 

4.

 

Getting Started 

Before you start using this controller, please read the manual carefully. This 
section only provides a brief description on some of the most basic operations of 
this controller. Please read the later sections in this manual to understand how this 
controller works and learn more about each parameter.  
 

4.1.

 

Power Up 

To test the unit and get familiar with all the features of this controller, please 
connect a PT100 RTD probe and then supply the 120 V or 240 V AC power.  
 

4.2.

 

Displayed Information 

When the controller is powered up for the first time, the top display will show 
current probe reading, and the bottom display will show the program status 

STOP

”.  

 
When the program is running but the temperature has not yet reached the set-
value of the current step (i.e., the step-timer has not started yet), the top window 
shows the current temperature reading, and the bottom display will flash between 
the current set-value and the current step number (Figure 3). When the step-timer 
has started, the top window will show the probe reading and the time alternatively, 
and the bottom window will still show the current set-value and the current step 
number alternatively (Figure 4). If the set-value has the letter “

P

” display on its left, 

that means this is a percentage value of power, not a temperature value.  
 

7 8

 1 5 0

7 8

m - 1

 

Figure 3. Two display screens when the step-timer has not started. 

 

1 4 9

 1 5 0

00

:

45

m - 1

 

Figure 4. Two display screens when the step-timer has started. 

 
 
There are four LED indicators on the left side. The top two red LED are 
synchronized with the relay AL1 and AL2 status respectively. The third LED is 

yellow, and it lights up if the controller is at MASH mode. The last green indicator 
is synchronized with the output signal to the external SSR.     
    

4.3.

 

Understand the Menu Structure 

The table below shows the menu structure of DSPR320 and how to access the 
menu. 
 
Table 5. Menu structure of DSPR320.   

Quick Access Menu  

(Short-press the knob to bring up the Quick Menu; rotate the knob to browse different 

options; press the knob again to select.) 

RST 

(n/y)

 

Reset the program 

STEP 

(1 ~ 9)

 

Jump to the selected step 

MODE 

(Mash/Boil)

 

Select mode 

Main Menu  

(Hold down the knob for 3 seconds to bring up the Main Menu; rotate the knob to 

browse different menu items; press the knob again to select. ) 

mPRG 

Mash mode program 

bPRG 

Boil program  

mSET 

Mash-step settings 

bSET 

Boil-step settings 

RELY 

Relay configurations 

SYST 

System configurations 

 
 

4.4.

 

Select Mash or Boil Mode 

There are two program modes: 

MASH

 and 

BOIL

. By default, the controller is at 

MASH mode. If you want to run the program in Boil mode, please press the knob 
to bring up the Quick Access Menu. Next, rotate the knob clock-wise till you see 

MODE

” in the top display and “

BOIL

” in the lower display. Then, press the knob 

again to confirm the selection. The MASH indicator will light up if the controller is 
in MASH mode, and it should turn off if the controller is in BOIL mode.  
 

R S T

   N

STEP

1

KNOB

Keep turning

KNOB

Press

7 8

stop

MODE

MASH

KNOB

Keep turning

KNOB

Press

MODE

B O I L

 

Figure 5. Select Program Mode on DSPR320. 

 

4.5.

 

Adjust Parameters 

All parameters are divided into four groups in the Main Menu: 

mSET

 (mashing 

step settings), 

bSET

 (boiling step settings), 

RELY

 (relay settings), and 

SYST

 

(system settings). Press the knob for 3 seconds to go the Main Menu and turn the 
knob to select the desired parameter group to edit. Please refer to Section 7 of this 
manual for the detailed explanation of each parameter.      
 

4.6.

 

Enter the Program 

Press down the knob for 3 seconds to go the main menu, the first two items are 

mPRG

 (Mash Mode Program) and 

bPRG

 (Boil Mode Program). Rotate the knob 

to select which program to enter and press the knob again to confirm.  
 
There are maximum 9 steps can be entered in each mode. For each step, the user 
will be asked to enter the set-value and the step-timer. The Figure 6 below shows 
the operations for how to enter the set-value of the Step 1 of the Mash Program. 
And the Figure 7 shows the same operations for Boil Program. 
 

KNOB

Press

7 8

stop

3 sec

GOTO

mPRG

KNOB

Press

M1 - s

M     0

M1 - t

0 0

:

0 0

KNOB

Tur n

M1 - s

M1 5 0

KNOB

Press

 

Figure 6. Entering the Mash Program.  

 
 

KNOB

Press

7 8

stop

3 sec

GOTO

bPRG

KNOB

Press

b1 - s

p     0

b1 - t

0 0

:

0 0

KNOB

Tur n

b1 - s

P   2 5

KNOB

Press

 

Figure 7. Entering the Boil Program.  

 

Содержание EZboil DSPR320

Страница 1: ...nt panel to the back Mounting cutout 45 x 45 mm 2 Front Panel 8 5 4 1 2 3 7 6 9 10 Figure 1 The front panel of DSPR320 2 1 Display Table 2 Front panel display Name Descriptions 1 Top Display Temperatu...

Страница 2: ...e menu structure of DSPR320 and how to access the menu Table 5 Menu structure of DSPR320 Quick Access Menu Short press the knob to bring up the Quick Menu rotate the knob to browse different options p...

Страница 3: ...how to pause the timer 0 0 4 5 m 1 HOLD 1 5 0 HOLD Press RUN m 1 RUN Press Figure 11 Operations to pause and to resume the step timer When the timer is paused from the key pad a dot will also appear i...

Страница 4: ...consist of the set value and the step timer The step timer only starts counting when the temperature has reached a pre defined timer start point see section 5 6 for details 5 4 Ramp Sections In DSPR3...

Страница 5: ...escription SKIP Bypass this step HOLD Hold the program at the current step Press RUN key to continue to the next step END End the program CONT End the MASH Program and continue to execute the first st...

Страница 6: ...ss the knob shortly When the controller is not executing any program i e the controller is at the END or the STOP status press the knob will bring up the RST function If a program has been started pre...

Страница 7: ...emperature Note 4 mOUT acceleration output power for mashing steps determines the maximum output power can be sent during the acceleration stage of heating up the water or wort toward the set temperat...

Страница 8: ...e previous step has ended and before the next step starts A ramp section is essentially a section between two steps when step timer isn t counting time Note 1 5 HEAT Relay will be activated during the...

Страница 9: ...han dH SV the alarm relay will be activated it will be deactivated when temperature drops below dH SV HY Similarly when the temperature is lower than SV dL the alarm relay will be activated it will be...

Страница 10: ...rewing in a BIAB setup In this example a DSPR320 is used to control the heater in a BIAB kettle The Relay 1 will be used to control the wort circulation pump during mashing and the Relay 2 will be use...

Страница 11: ...he Relay 1 pin 1 and 2 on DSPR320 to control a R30A 120V coil relay which supplies power to a 15A socket End Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Em...

Отзывы: