TI033
400-033-001-C 30/11/06 2/2
q
Press the
HOUR
and
MIN
buttons to set the
ON
time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that
PM
appears on the screen when an
afternoon time is displayed.
r
After you have programmed the
ON
time, press the
PGM
button
to display the
OFF
time (time when you want the lights to turn
off).
s
Repeat steps 3 through 5 to program the
OFF
time. If the program
ON
time is set for every day
of the week, the program
OFF
time will
automatically be set for every day.
t
To set another program, repeat steps 2 through 6. Programs that
are not set will remain inactive.
u
Press one of the control buttons or close the switch door to
return to normal operation.
Clearing a Program
Press the
PGM
button until the desired program is selected. Hold the
PGM
button for 3 seconds.
- : - -
appears when the program is
erased.
Supply
: 120 VAC, 50 / 60 Hz
Maximum load
: 2400 watts resistive or inductive, 1 HP motor
Operating temperature range
: 5°F to 122°F (-15°C to 50°C)
Storage temperature range
: -4°F to 122°F (-20°C to 50°C)
Power outage
: The programs are protected by a rechargeable
battery. The screen is blank during the power outage.
Certifications
: CSA & UL
AUBE warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and ser-
vice, for a period of three (3) years from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, AUBE shall repair or
replace it (at AUBE's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or
(ii)
contact AUBE. AUBE will make the determination whether the
product should be returned, or whether a replacement product
can be sent to you.
This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by AUBE that the defect or mal-
function was caused by damage which occurred while the product
was in the possession of a consumer.
AUBE's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI-
DENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces, states or regions do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limita-
tions on how long an implied warranty lasts, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from one province, state or region to another.
If you have any questions on the product installation or operation,
contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]
For more information on our products, go to
www.aubetech.com
t
Troubleshooting
7.
Blank display
• Verify circuit breaker at main panel.
• Ensure the
ON/OFF
selector is at
ON
.
• Reset the switch using a paper clip.
Faded or irregular
display
Ambient temperature below freezing
point
Cannot switch between
24-hour format and
12-hour format
First, press one of the control buttons so
that
MAN
or
AUTO
appears on display.
Programs do not run
as expected
• Make sure the switch is properly pro-
grammed.
• Note that
- : - -
indicates an inactive pro-
gram,
00:00
indicates midnight.
• If the switch has been configured for
12-hour format, check that
PM
appears
on the left side of the screen when an
afternoon time is displayed.
The switch resets itself
without apparent rea-
son when used to con-
trol an inductive load
such as a relay or a
contactor.
The reset is caused by the load. Install a
snubber (AC130-03) at each relay/con-
tactor.
u
Technical Specifications
8.
;
Warranty
9.
Customer Assistance
10.
TROUBLESHOOTING
400-033-001-C ENG (print at 90%).fm Page 2 Thursday, November 30, 2006 8:50 AM