background image

TI033

      400-033-001-C                    30/11/06                    2/2

q

Press the 

HOUR

 and 

MIN

 buttons to set the 

ON

 time (time when 

you want the lights to turn on). If you have selected the 12-hour 
format, ensure that 

PM

 appears on the screen when an 

afternoon time is displayed.

r

After you have programmed the 

ON

 time, press the 

PGM

 button 

to display the 

OFF

 time (time when you want the lights to turn 

off).

s

Repeat steps 3 through 5 to program the 

OFF

 

time. If the program 

ON

 time is set for every day 

of the week, the program 

OFF

 time will 

automatically be set for every day.

t

To set another program, repeat steps 2 through 6. Programs that 
are not set will remain inactive.

u

Press one of the control buttons or close the switch door to 
return to normal operation.

Clearing a Program

Press the 

PGM

 button until the desired program is selected. Hold the

PGM

 button for 3 seconds. 

- : - -

 appears when the program is

erased.

Supply

: 120 VAC, 50 / 60 Hz 

Maximum load

: 2400 watts resistive or inductive, 1 HP motor

Operating temperature range

: 5°F to 122°F (-15°C to 50°C)

Storage temperature range

: -4°F to 122°F (-20°C to 50°C)

Power outage

: The programs are protected by a rechargeable 

battery. The screen is blank during the power outage. 

Certifications

: CSA & UL

AUBE warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and ser-
vice, for a period of three (3) years from the date of purchase by the
consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, AUBE shall repair or
replace it (at AUBE's option).
If the product is defective,
(i)

return it, with a bill of sale or other dated proof of purchase, to
the place from which you purchased it, or 

(ii)

contact AUBE. AUBE will make the determination whether the
product should be returned, or whether a replacement product
can be sent to you.

This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by AUBE that the defect or mal-
function was caused by damage which occurred while the product
was in the possession of a consumer.
AUBE's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI-
DENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some provinces, states or regions do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limita-
tions on how long an implied warranty lasts, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may have other
rights which vary from one province, state or region to another.

If you have any questions on the product installation or operation,
contact us at:

705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]

For more information on our products, go to 

www.aubetech.com

t

Troubleshooting

7.

Blank display

• Verify circuit breaker at main panel.
• Ensure the 

ON/OFF 

selector is at 

ON

.

• Reset the switch using a paper clip.

Faded or irregular 
display

Ambient temperature below freezing
point

Cannot switch between 
24-hour format and 
12-hour format

First, press one of the control buttons so 
that 

MAN

 or 

AUTO

 appears on display.

Programs do not run 
as expected

• Make sure the switch is properly pro-
grammed. 
• Note that 

- : - -

 indicates an inactive pro-

gram, 

00:00

 indicates midnight.

• If the switch has been configured for 
12-hour format, check that 

PM

 appears 

on the left side of the screen when an 
afternoon time is displayed.  

The switch resets itself 
without apparent rea-
son when used to con-
trol an inductive load 
such as a relay or a 
contactor.

The reset is caused by the load. Install a 
snubber (AC130-03) at each relay/con-
tactor.

u