background image

Owner’s Guide

6

1)

Install the base onto an electrical box.

2)

Place the FAN switch as follows:

Place at 

Yes

 if you have a fan-forced 

heater (to prevent premature burnout 
of the motor).

Leave at 

No

 for better temperature 

regulation if you do not have a 
fan-forced heater.

3)

Reinstall the faceplate on the base and 
secure it in place with the screw.

4)

Apply power to the thermostat at the 
main electrical panel.

Installing the thermostat

Keep air vents at top and
bottom of thermostat clean and
unobstructed at all times.

If you change the FAN switch position 

after

 you 

have already applied power to the thermostat, 
disconnect power to the thermostat at the 
electrical panel for 3 seconds. The thermostat 
will use the new setting when you reapply power.

FAN

 switch

Содержание TH303

Страница 1: ...TH303 Programmable Thermostat Owner s Guide 69 2680EF 07...

Страница 2: ...ing the thermostat 6 Quick start up Setting the clock 7 Operating modes Automatic Auto mode 8 Manual Man mode 9 Away mode 10 Countdown mode 11 Configuration Default schedule 12 Modifying the schedule...

Страница 3: ...a convector or a fan forced heater The thermostat CANNOT be used with a resistive load under 0 83 A a resistive load over 10 4 A a system driven by a contactor or a relay inductive load a central hea...

Страница 4: ...once The setpoint will be displayed for 5 seconds To modify the setpoint temperature press the Up or Down button until the desired value is displayed To enter or exit the programming mode press the S...

Страница 5: ...ture Heating intensity indicator No icon appears when heating is off Time Periods see page 12 Countdown mode see page 11 Manual mode see page 9 Day Automatic mode see page 8 Away mode see page 10 Setp...

Страница 6: ...lation must be carried out by a certified electrician and must comply with national and local electrical codes Loosen the screw holding the faceplate to the base The screw cannot be completely removed...

Страница 7: ...wire and the other one to the power supply wire using solderless connectors for copper wires NOTE Special CO ALR solderless connectors must be used when connecting with aluminium conductors Wiring 2...

Страница 8: ...the faceplate on the base and secure it in place with the screw 4 Apply power to the thermostat at the main electrical panel Installing the thermostat Keep air vents at top and bottom of thermostat c...

Страница 9: ...an access the Time menu by pressing the Select button for 3 seconds and then pressing the Up button once Quick Start up Setting the clock and date Time Menu Select the format Set the hour Set the minu...

Страница 10: ...While the thermostat is in Automatic mode you can press the Up or Down button to modify the temperature The new temperature will be used until the end of the current period Auto will flash during the...

Страница 11: ...at the same temperature indefinitely In this mode the thermostat will remain at this temperature until you press the Up or Down button to change it To place the thermostat in Manual Man mode Manual Ma...

Страница 12: ...is set by default at 15 C 59 F and cannot be modified by simply pressing the Up or Down button To modify the Away temperature see page 16 NOTE The Away mode can also be used to prevent tampering of t...

Страница 13: ...e and uses the temperature programmed for that mode At any time you can cancel the Countdown mode by pressing the Select button To place the thermostat in Countdown mode Countdown mode Set time Normal...

Страница 14: ...ituation For example Leave and Return periods are skipped for the weekend in the default schedule You can choose a different program every day i e each period can have a different starting time and a...

Страница 15: ...l be replaced by dashes NOTE If you do not press any button for one minute the thermostat will automatically save any changes you have made and will return to its normal display Modifying the schedule...

Страница 16: ...dify the menu parameters see page 16 Setup menu 1 2 Display Parameter Options Default setting Temperature unit C F C Away temperature 1 5 C 30 C 41 F 86 F 15 C 59 F Daylight Saving Time 2 On Off On Ea...

Страница 17: ...d Sunday of March and to normal time on the first Sunday of November 3 Early Start Early Start is used in Automatic mode only When Early Start is enabled On the thermostat determines when to start hea...

Страница 18: ...wice to enter the Configuration Conf menu Setup procedure Configuration Menu Set unit of temperature Set Away temperature Set Daylight Saving Time Set Early Start To confirm To confirm To confirm To c...

Страница 19: ...located near or above a heat source such as a light dimmer The thermostat displays LP instead of the temperature The screen is blank The thermostat is currently without power This can happen in eithe...

Страница 20: ...s in Automatic mode Check the clock Time menu and the schedule Prog menu If the thermostat is configured for 12 hour format ensure that AM or PM appears on the screen LO is displayed The measured temp...

Страница 21: ...ution 0 5 C 1 F Operation 0 C to 50 C 32 F to 120 F Storage 20 C to 50 C 4 F to 120 F Permanent memory You do not need to adjust the temperature settings or the thermostat s configurations following a...

Страница 22: ...while the product was in the possession of a consumer Resideo s sole responsibility shall be to repair or replace the product within the terms stated above RESIDEO SHALL NOT BE LIA BLE FOR ANY LOSS O...

Страница 23: ...toll free at 1 800 468 1502 Customer assistance To reset the thermostat press both Down and Select buttons and hold After 3 seconds RST appears After the next 5 seconds when RST disappears release the...

Страница 24: ...th Golden Valley MN 55422 69 2680EF 07 M S Rev 04 21 Printed in United States FCC statement available at https customer resideo com en US support residential codes and standards FCC15105 Pages default...

Страница 25: ...TH303 Thermostat programmable Guide du propri taire...

Страница 26: ...apide R glage de l horloge 7 Modes de fonctionnement Mode Automatique Auto 8 Mode Manuel Man 9 Mode Absence Away 10 Mode Compte rebours Countdown 11 Configuration Horaire par d faut 12 Modification de...

Страница 27: ...un ventilo convecteur Ce thermostat NE PEUT tre utilis avec une charge r sistive inf rieure 0 83 A une charge r sistive sup rieure 10 4 A un appareil muni d un contacteur ou d un relais charge induct...

Страница 28: ...ne s affichera pendant 5 secondes Pour modifier la temp rature de consigne appuyer sur le bouton Haut ou Bas jusqu ce que la valeur d sir e soit affich e Pour entrer ou sortir du mode de programmation...

Страница 29: ...ffage L absence de l ic ne indique l arr t du chauffage Heure P riodes voir la page 12 Mode Compte rebours voir la page 11 Mode Manuel voir la page 9 Jour Mode Automatique voir la page 8 Mode Absence...

Страница 30: ...E L installation doit tre effectu e par un lectricien certifi et doit tre conforme aux codes nationaux et locaux de l lectricit Desserrer la vis qui retient la fa ade du thermostat la base La vis ne p...

Страница 31: ...autre fil au fil de l alimentation en utili sant des connecteurs sans soudure pour fils de cuivre NOTA Pour le raccordement des fils en aluminium employer des connecteurs con us cette fin et identifi...

Страница 32: ...vecteur 3 Remettre la fa ade du thermostat sur la base et resserrer la vis 4 Mettre le thermostat sous tension partir du panneau lectrique Installer le thermostat Garder les ouvertures d a ration au d...

Страница 33: ...appuyant sur le bouton S lection pendant 3 secondes et par la suite en appuyant une fois sur le bouton Haut D marrage rapide R glage de l horloge et de la date Menu de l heure S lectionner le format...

Страница 34: ...en mode Automatique vous pouvez appuyer sur le bouton Haut ou Bas pour modifier la temp rature La nouvelle temp rature sera utilis e jusqu la fin de la p riode en cours Auto clignotera pendant la d r...

Страница 35: ...emp rature ind finiment Dans ce mode le thermostat gardera cette temp rature jusqu ce que vous la modifiez l aide du bouton Haut ou Bas Pour mettre le thermostat en mode Manuel Man Mode Manuel Man R g...

Страница 36: ...par d faut Elle ne peut tre modifi e en appuyant simplement sur le bouton Haut ou Bas Pour modifier la temp rature Absence voir la page 16 NOTA Le mode Absence peut aussi tre utilis pour emp cher qu o...

Страница 37: ...ce mode tout moment vous pouvez annuler le mode Compte rebours en appuyant sur le bouton S lection Pour placer le thermostat en mode Compte rebours Mode Compte rebours Countdown R gler l heure Afficha...

Страница 38: ...exemple dans l horaire par d faut les p riodes D part Leave et Retour Return sont omises pour la fin de semaine Vous pouvez choisir un programme diff rent chaque jour c d que chaque p riode peut avoi...

Страница 39: ...appuyez sur aucun bouton pendant une minute le thermostat enregistrera automatiquement toutes les modifications que vous avez apport es et reviendra son affichage normal Modification de l horaire Menu...

Страница 40: ...voir la page 16 Menu de configuration 1 2 Affichage Param tre Options R glage par d faut Unit de la temp rature C F C Temp rature Absence 1 5 C 30 C 41 F 86 F 15 C 59 F Heure avanc e 2 Activ e On D sa...

Страница 41: ...embre 3 D marrage anticip Le d marrage anticip ne peut tre utilis qu en mode Automatique Lorsque le d marrage anticip est activ On le thermostat d termine l heure du d marrage du chauffage afin que la...

Страница 42: ...r acc der au menu de configuration Conf tapes de configuration Menu de configuration Unit de temp rature Temp rature Absence Heure avanc e D marrage anticip Pour confirmer Pour confirmer Pour confirme...

Страница 43: ...stat est situ pr s ou au dessus d une source de chaleur telle qu un gradateur de lumi re Le thermostat affiche LP la place de la temp rature L cran est vide Le thermostat est hors tension Ceci peut tr...

Страница 44: ...ique V rifier l horloge menu Time et l horaire menu Prog Si le thermostat est configur en format 12 heures s assurer que AM ou PM appara t l cran Le thermostat affiche LO La temp rature mesur e est in...

Страница 45: ...ge 0 5 C 1 F Fonctionnement 0 C 50 C 32 F 120 F Entreposage 20 C 50 C 4 F 120 F M moire permanente Il n est pas n cessaire d ajuster les r glages de temp rature ou les configurations du thermostat apr...

Страница 46: ...ou remplacer le produit conform ment aux modalit s susmentionn es RESIDEO N EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES D COULANT DIRECTEMENT O...

Страница 47: ...s frais le 1 800 468 1502 Service la client le Pour r initialiser le thermostat appuyer sur les boutons Bas et S lection et les tenir enfonc s Apr s 3 secondes RST appara t Cinq secondes plus tard lor...

Страница 48: ...Valley MN 55422 69 2680EF 07 M S Rev 04 21 Imprim aux tats Unis D claration de la FCC sur https customer resideo com en US support residential codes and standards FCC15105 Pages default aspx MISE EN...

Отзывы: