background image

Installation & User’s Instructions

for use with all Potterton Combination Boilers

Single Channel Wireless Programmable 

Room Thermostat

Kit N

o

5117391

Please leave these Instructions

with the User.

A

B

C

D

Comp N

o

5117490 - Iss 5 - 11/06

B A X I

A   T r a d i n g   D i v i s i o n   o f   B a x i   H e a t i n g   U K   L t d

Brooks House, Coventry Road, Warwick, CV34 4LL
After Sales Service 08706 096 096 Technical Enquiries 08706 049 049
Website www.potterton.co.uk
e&oe

company

WARNING: Isolate at supply before access.

1. Undo the screws securing the boiler outer case and remove the boiler outer case.

2. Undo the screws retaining the facia and hinge the facia down.

3. If there is a Receiver Cover Panel then undo the screws and remove it.

4. From inside the facia panel, spring the securing barbs of the facia blanking plate and push
through the facia to release.

5. Take the receiver from the box and fit it to the facia panel.

NOTE:

Do not fit the batteries to the transmitter at this stage.

Facia
Panel

Receiver

Facia Blanking
Plate

PCB removed
for clarity

PCB

Receiver
Cover Panel

SOCKET

1

/

4

Turn Facia

Securing Screws

Facia
Panel

Receiver

Receiver
Cover Panel

Facia Blanking

Plate

1

2

3

4

br - Brown
b - Blue
r - Red

br

b

r

E

FITTING THE RECEIVER TO THE BOILER

5

Installation & User’s Instructions

for use with all Baxi Combination Boilers

Single Channel Wireless Programmable 

Room Thermostat

Kit N

o

5117391

Please leave these Instructions

with the User.

Comp N

o

5117490 - Iss 1 - 12/05

Baxi Heating UK Limited
Brownedge Road Bamber Bridge Preston Lancashire PR5 6UP
After Sales Service 08706 096 096 Technical Enquiries 08706 049 049
Website www.baxi.co.uk

KIT CONTENTS IDENTIFICATION

Key No

Description

No Off

A

Instructions

1

B

Programmable Room Thermostat (Transmitter)

1

C

Receiver Unit

1

D

Battery (1.5VL26/AA)

2

E

Screw Plastite Pozi

3

Отзывы: