2)

Set the humidity level or offset using the 

 buttons.

• humidity level: 5% to 60%
• offset: -9% to 9%

3)

Press the 

 button to exit.

The 

 symbol is displayed when the humidifier is On.

The controller can be placed in unoccupied mode via a remote con-
trol device such as Aube’s CT241 telephone controller (see section
2.10). In this mode, the setpoint is set back by 4.5°C (8°F); it is low-
ered in heating mode or raised in cooling mode. The 

 icon

appears during the unoccupied mode.

NOTE

: Automatic changeover is disabled during the unoccupied

mode.

If you change the temperature setpoint (using the 

 buttons) in

unoccupied mode, the controller temporarily bypasses the current
setpoint. The new setpoint will be maintained for 2 hours, after
which the controller will return to the previous setpoint. The 

 icon

flashes during the bypass.

CT280-HP-2H1C Control Module

Power supply

: 24 VAC 

Current consumption

: 150 mA

Maximum load per output

: 1 A @ 24 VAC

Short cycle protection

: 2 minutes

Control cycles

: 2 to 6 per hour

Operating temperature

: 0°C to 50°C (32°F to 122°F)

Storage temperature

: -20°C to 50°C (-4°F to 122°F)

Humidity conditions

: 0% to 95%, non-condensing

Dimensions

: 76 mm x 109 mm x 25 mm (3 in. x 4.3 in. x 1 in.)

TH146 Console

Temperature setpoint range

: 5°C to 30°C (40°F to 86°F)

Humidity setpoint range

: 5% to 60%

Indoor temperature display range

: 0°C to 70°C (32°F to 158°F)

Outdoor temp. display range

: -50°C to 70°C (-58°F to 158°F)

Temperature display resolution

: 0.5°C (1°F)

Program protection

: non-volatile memory

Operating temperature

: 0°C to 50°C (32°F to 122°F)

Storage temperature

: -20°C to 50°C (-4°F to 122°F)

Humidity conditions

: 0% to 95%, non-condensing 

Dimensions

: 79 mm x 79 mm x 24 mm (3.1 in. x 3.1 in. x 1 in.)

Aube warrants this product, excluding battery, to be free from
defects in the workmanship or materials, under normal use and
service, for a period of three (3) years from the date of purchase by
the consumer. If at any time during the warranty period the product
is determined to be defective or malfunctions, Aube shall repair or
replace it (at Aube's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to

the place from which you purchased it, or 

(ii) contact Aube. Aube will make the determination whether the

product should be returned, or whether a replacement product
can be sent to you.

This warranty does not cover removal or reinstallation costs. This
warranty shall not apply if it is shown by Aube that the defect or
malfunction was caused by damage which occurred while the
product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product
within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE
OF THIS PRODUCT. Some provinces and states do not allow the
exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE
MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR
DURATION OF THIS WARRANTY. Some provinces and states do
not allow limitations on how long an implied warranty lasts, so the
above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have
other rights which vary by province, state or region.

If you have any questions about the product installation or
operation, or concerning the warranty, contact us at the address
shown below.

For more information on our products, visit us at:

www.aubetech.com

5.6

 Unoccupied Mode

5.7

 Temporary Bypass

6. Technical Specifications

Humidity 
level set 
by user

Offset set 
by user

Humidity level 
set by controller

7. Warranty

8. Support

705 Montrichard 
Saint-Jean-sur-Richelieu, Quebec 
J2X 5K8
Canada
Tel: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: [email protected]

10, rue Ampère
95500 Gonesse
France
Tel: 33 (0) 1 34 07 99 00
Fax: 33 (0) 1 34 07 99 19
Email: [email protected]

Содержание Non-programmable Heat Pump Controller TH146-N-DE

Страница 1: ...e or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires t...

Страница 2: ...num and position it such that its aperture faces the air flow Connect the sensor to controller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor...

Страница 3: ...outdoor tem perature sensor is not connected to the controller The auxiliary heat is activated during defrost except under the fol lowing conditions When the outdoor temperature is above the defrost p...

Страница 4: ...r temperature display On OF On Select between displaying the outdoor temperature or display ing the indoor humidity level On Displays the outdoor temperature OF Off Displays the indoor humidity level...

Страница 5: ...ion Diagram New Installation TH146 AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Auxiliary Heat Defrost Fan Valve Red Yellow Green Dual Energy 16 18 AWG 16 22 AWG 16 22...

Страница 6: ...V Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump CT280 HP 2H1C Red Compressor Valve Defrost Fault Furnace Fan Limit Yellow Green 16 22 AWG 16 22...

Страница 7: ...aced in manual mode or in auto matic mode see page 4 item 11 Manual Adjustment In manual mode the user sets the humidity level 5 to 60 Automatic Adjustment In automatic mode the controller sets the hu...

Страница 8: ...functions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii c...

Отзывы: