Aube Technologies Non-programmable Heat Pump Controller TH146-N-DE Скачать руководство пользователя страница 7

TH146-N-DE

User’s Guide

Non-programmable Heat Pump Controller

TH146-N-DE 

      400-280-000-G                    9/22/06                    7/8

Press 

MODE

 to place the controller in one of the following modes.

Press the 

 button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is
activated.

In continuous mode, the fan runs continuously and the   sym-
bol is displayed. 

NOTE

: If the “smart fan” feature is enabled,

the fan will run only when heating or cooling will be activated
during unoccupied mode.

Depending on how the controller has been configured (see page 4,
item 9), it displays either the measured indoor humidity level or the
measured outdoor temperature.

The actual (measured) temperature is normally displayed. To view
the temperature setpoint, press one of the 

 buttons once. The

setpoint is displayed for 5 seconds and is indicated by the   sym-
bol. 

To modify the temperature setpoint, press one of the 

 buttons

until the desired temperature is displayed.

NOTE

: If the controller is in automatic heat/cool changeover, the

setpoint is automatically reduced or raised by 1°C (2°F) when the
controller switches to heating mode or to cooling mode respectively.
For example, if you place the setpoint at 24°C (75°F) while in heat-
ing mode, the setpoint will become 25°C (77°F) in cooling mode and
will return to 24°C (75°F) when the controller switches back to heat-
ing mode.

The humidity adjustment can be placed in manual mode or in auto-
matic mode (see page 4, item 11).

Manual Adjustment

In manual mode, the user sets the humidity level (5% to 60%).

Automatic Adjustment

In automatic mode, the controller sets the humidity level based on
the outdoor temperature to prevent ice formation or condensation
on windows. However, the user can apply an offset (-9% to 9%). For
example, the user can enter a negative offset if there is too much
condensation on the windows.

Procedure

The procedure to set the humidity level (in manual mode) or the off-
set (in automatic mode) is as follows:

1)

Press the 

Mode

 button for 3 seconds.

One of the following displays appears:

System fault

Temperature adjustment

Fan operating 
mode selection

System operating 
mode selection

System 
operating mode

Fan is in continuous mode

Unoccupied 
mode is On

Outdoor 
temperature or 
indoor humidity

Indoor temperature

Auxiliary heat is On

Heating is On

Cooling is On

Emergency heat 
mode

Dual-energy 
mode

Humidifier 
is On

Appears when the 
temperature setpoint 
is displayed

5. Operation

5.1

 System Operating Mode (Heating/Cooling)

HEAT

The system is in heating mode.

COOL

The system is in cooling mode.

AUTO

The system is in automatic changeover. (The system 
switches between heating mode and cooling mode to main-
tain the desired temperature.)

OFF

Both heating or cooling are off.

EHEAT

The system is in emergency heat mode. Only auxiliary heat-
ing is used when there is a call for heat.

5.2

 Fan Operating Mode (On/Auto)

5.3

 Indoor Humidity / Outdoor Temperature Display

Outdoor

temperature

Indoor 
humidity

5.4

Temperature Adjustment

5.5

 Humidity Adjustment

Содержание Non-programmable Heat Pump Controller TH146-N-DE

Страница 1: ...e or air outlet or stagnant air behind a door Do not install the console on a wall hiding air ducts nor expose it to direct sunlight NOTE If this controller replaces an existing thermostat the wires t...

Страница 2: ...num and position it such that its aperture faces the air flow Connect the sensor to controller terminals PS and CS no polarity For more information refer to the instructions provided with the sen sor...

Страница 3: ...outdoor tem perature sensor is not connected to the controller The auxiliary heat is activated during defrost except under the fol lowing conditions When the outdoor temperature is above the defrost p...

Страница 4: ...r temperature display On OF On Select between displaying the outdoor temperature or display ing the indoor humidity level On Displays the outdoor temperature OF Off Displays the indoor humidity level...

Страница 5: ...ion Diagram New Installation TH146 AC144 03 AC146 410 CT241 Humidifier Heat Pump Compressor Fault CT280 HP 2H1C Auxiliary Heat Defrost Fan Valve Red Yellow Green Dual Energy 16 18 AWG 16 22 AWG 16 22...

Страница 6: ...V Transformer Dual Energy AC144 03 AC146 410 CT241 RC845 Humidifier Auxiliary Heating System Heat Pump CT280 HP 2H1C Red Compressor Valve Defrost Fault Furnace Fan Limit Yellow Green 16 22 AWG 16 22...

Страница 7: ...aced in manual mode or in auto matic mode see page 4 item 11 Manual Adjustment In manual mode the user sets the humidity level 5 to 60 Automatic Adjustment In automatic mode the controller sets the hu...

Страница 8: ...functions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii c...

Отзывы: